Establishing network connections

TX 4000 PCI SS7 Network Interface Board Installation Manual

Dual-node redundant signaling server

The following illustration shows how to set up two TX 4000 boards based on a dual- node redundant signaling server in an IP network configuration. The boards are located in two separate chassis to ensure board-level and system-level redundancy.

Single-node redundant signaling server

The following illustration shows how to set up two TX 4000 boards based on a single- node signaling server in an IP network configuration. The boards are located in the same chassis to ensure board-level redundancy.

For more information on SS7 redundancy, refer to the Dialogic® TX Series SS7 Boards Health Management Developer's Reference Manual.

36

Dialogic Corporation

Image 36
Contents July Copyright and legal notices Revision history Revision Release datePage Table Of Contents Hardware specifications Introduction Current terminologyPage TX 4000 board features Overview of the TXBoard TX 4000 board provides PCI bus connectivity Software components Utilities and demonstration programs Utility DescriptionProgram Demonstrates how to Page Installing the TX 4000 board System requirementsInstallation summary Step Description For details, refer toConfiguring the hardware Configuring H.100 bus terminationConfiguring SS7 Monitor mode DIP switch S1 Installing the board Step ActionConfiguring the TX 4000 board Using the configuration utilityDirectory Assigning a CP number TxcpcfgAdding a board Txcpcfg bus slot updatedCPnumber Changing a CP numberMoving a board Removing a board Saving configuration changes # Command Bus Slot CP Number TxcpcfgPage Connectors and cables Establishing networkConnections Dialogic MD1 RJ-45 interfaceDual T1/E1 120 ohm adapter cable Ethernet interfacesConnecting to the network E1 network considerations T1 network considerationsTesting in loopback mode Connecting TX boards for redundancy TDM configurationSingle-node redundant signaling server IP network configurationDual-node redundant signaling server Verifying the installation Off Trunk has not been configuredExternal connection status LEDs Ethernet LEDs Following table describes the functionality of each LEDBoot code Leds Board status LEDsColor Status when illuminated Number Status LEDsVerifying the board installation Page Hardware specifications General hardware specificationsFeature Specification PhysicalPower requirements Compliant interfaceEnvironment Software environmentCept E1 G.703 telephony interface DSX-1 telephony interfacePage Index Sigtran