Dialogic TX4000 PCI SS7 Compliant interface, Environment, Software environment, Connectivity

Page 44

Hardware specifications

TX 4000 PCI SS7 Network Interface Board Installation Manual

H.100 compliant interface

H.100 compliant interface has the following features:

Flexible connectivity between T1 and E1 trunks and the H.100 bus

Access to any of 4096 H.100 timeslots

Compatible with any H.100 compliant telephony interface

H.100 clock master or clock slave

H.100 bus termination capability

Environment

Feature

Description

 

 

Operating temperature

0 to 50 °C

 

 

Storage temperature

-20 to 70 °C

 

 

Humidity

5% to 80%, non-condensing

 

 

Software environment

Feature

Description

 

 

Development environment

NaturalAccess Software

 

 

Operating system

Windows

 

UNIX

 

 

Power requirements

State Requirements

TX 4000

0.1A maximum @ 12.0 V

0.5A maximum @ 5.0 V

6.5A maximum @ 3.3 V

Connectivity

Feature

Description

 

 

Ethernet

Two 10/100Base-T Ethernet interface with RJ-45 connectors for connecting to either

connectivity

a network of other SIGTRAN devices or for connecting to a redundant mate board.

 

 

PSTN network

Two T1/E1 Dialogic® MD1 RJ-45 interfaces

connectivity

 

 

 

Intra-chassis

H.100 bus. Lucent Ambassador T8100A with 256 half duplex or 128 full duplex

connectivity

timeslots

 

 

44

Dialogic Corporation

Image 44
Contents July Copyright and legal notices Revision history Revision Release datePage Table Of Contents Hardware specifications Introduction Current terminologyPage Board TX 4000 board featuresOverview of the TX TX 4000 board provides PCI bus connectivity Software components Utilities and demonstration programs Utility DescriptionProgram Demonstrates how to Page Installing the TX 4000 board System requirementsInstallation summary Step Description For details, refer toConfiguring the hardware Configuring H.100 bus terminationConfiguring SS7 Monitor mode DIP switch S1 Installing the board Step ActionDirectory Configuring the TX 4000 boardUsing the configuration utility Assigning a CP number TxcpcfgAdding a board Txcpcfg bus slot updatedCPnumber Changing a CP numberMoving a board Removing a board Saving configuration changes # Command Bus Slot CP Number TxcpcfgPage Connectors and cables Establishing networkConnections Dialogic MD1 RJ-45 interfaceDual T1/E1 120 ohm adapter cable Ethernet interfacesConnecting to the network E1 network considerations T1 network considerationsTesting in loopback mode Connecting TX boards for redundancy TDM configurationSingle-node redundant signaling server IP network configurationDual-node redundant signaling server External connection status LEDs Verifying the installationOff Trunk has not been configured Ethernet LEDs Following table describes the functionality of each LEDBoot code Leds Board status LEDsColor Status when illuminated Number Status LEDs Verifying the board installation Page Hardware specifications General hardware specificationsFeature Specification PhysicalPower requirements Compliant interfaceEnvironment Software environmentCept E1 G.703 telephony interface DSX-1 telephony interfacePage Index Sigtran