Dialogic TX4000 PCI SS7 Cept E1 G.703 telephony interface, DSX-1 telephony interface

Page 45

TX 4000 PCI SS7 Network Interface Board Installation Manual Hardware specifications

CEPT E1 G.703 telephony interface

Feature

Specification

 

 

Interface

G.703 2048 kbit/s trunk interface

 

 

Line code

HDB3 (in zero code suppression) or AMI

 

 

Alarm signal

Loss of frame alignment, out of frame conditions, loss of signaling multiframe

capabilities

alignment and loss of CRC multiframe alignment (red), remote alarm and remote

 

multiframe alarm (yellow), alarm indication signal (AIS)

 

 

Counts

Bit error rate, CRC errors, slips, line code violations, far-end block errors

 

 

Loopback

Per channel and across channels under software control

 

 

Connectors

Two Dialogic® MD1 RJ-45 interfaces that can support up to four 120 ohm RJ-48C trunk

 

connectors (using two dual T1/E1 trunk adapter cables).

 

 

DSX-1 telephony interface

Feature

Specification

 

 

Interface

ANSI T1.102, T1.403

 

 

Framing

D4, ESF

 

 

Line code

AMI

 

 

Zero bits

Selectable B8ZS, jammed bit (ZCS) or no zero code suppression

 

 

Alarm signal

Yellow and red

capabilities

 

 

 

Counts

Bipolar violation, F(t) error, and CRC error

 

 

Loopback

Per channel and overall under software control. Automatic remote loopback with

 

CSU option.

 

 

Connectors

Two Dialogic® MD1 RJ-45 interfaces that can support up to four 120 ohm RJ-48C

 

trunk connectors (using two dual T1/E1 trunk adapter cables).

 

 

Maximum cable

655 feet of 22 AWG twisted pair

length

 

 

 

Dialogic Corporation

45

Image 45
Contents July Copyright and legal notices Revision Release date Revision historyPage Table Of Contents Hardware specifications Current terminology IntroductionPage TX 4000 board features Overview of the TXBoard TX 4000 board provides PCI bus connectivity Software components Utility Description Utilities and demonstration programsProgram Demonstrates how to Page System requirements Installing the TX 4000 boardStep Description For details, refer to Installation summaryConfiguring H.100 bus termination Configuring the hardwareConfiguring SS7 Monitor mode DIP switch S1 Step Action Installing the boardConfiguring the TX 4000 board Using the configuration utilityDirectory Txcpcfg Assigning a CP numberAdding a board Changing a CP number Txcpcfg bus slot updatedCPnumberMoving a board Removing a board # Command Bus Slot CP Number Txcpcfg Saving configuration changesPage Establishing network Connectors and cablesConnections Dialogic MD1 RJ-45 interfaceEthernet interfaces Dual T1/E1 120 ohm adapter cableConnecting to the network T1 network considerations E1 network considerationsTesting in loopback mode TDM configuration Connecting TX boards for redundancyIP network configuration Single-node redundant signaling serverDual-node redundant signaling server Verifying the installation Off Trunk has not been configuredExternal connection status LEDs Following table describes the functionality of each LED Ethernet LEDsBoard status LEDs Boot code LedsStatus LEDs Color Status when illuminated NumberVerifying the board installation Page General hardware specifications Hardware specificationsFeature Specification PhysicalCompliant interface Power requirementsEnvironment Software environmentDSX-1 telephony interface Cept E1 G.703 telephony interfacePage Index Sigtran