CY7C1166V18, CY7C1177V18
CY7C1168V18, CY7C1170V18
Capacitance
Tested initially and after any design or process change that may affect these parameters.
Parameter | Description | Test Conditions | Max | Unit | |
CIN | Input Capacitance | TA = 25°C, f = 1 MHz, | 5 | pF | |
|
| VDD = 1.8V |
|
| |
CCLK | Clock Input Capacitance | 6 | pF | ||
VDDQ = 1.5V | |||||
CO | Output Capacitance |
| 7 | pF |
Thermal Resistance
Tested initially and after any design or process change that may affect these parameters.
Parameter | Description | Test Conditions | 165 FBGA | Unit | |
Package | |||||
|
|
|
| ||
ΘJA | Thermal Resistance | Test conditions follow standard test methods and | 17.2 | °C/W | |
| (junction to ambient) | procedures for measuring thermal impedance, in |
|
| |
|
| accordance with EIA/JESD51. |
|
| |
ΘJC | Thermal Resistance | 4.15 | °C/W | ||
| |||||
| (junction to case) |
|
|
| |
|
|
|
|
|
AC Test Loads and Waveforms
Figure 6. AC Test loads and Waveforms
VREF = 0.75V
VREF |
|
|
|
|
|
|
| 0.75V |
|
| ||||
|
|
|
|
|
|
|
|
| ||||||
OUTPUT |
|
|
|
|
|
|
|
| Z0 = 50Ω |
|
| |||
|
|
|
|
|
|
|
|
|
| |||||
DEVICE |
|
|
|
|
|
|
|
|
| |||||
UNDER |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
TEST |
|
|
|
|
|
|
|
|
|
|
|
|
|
ZQ
RQ =
250Ω
(a)
RL = 50Ω
VREF = 0.75V
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VREF |
|
|
|
|
|
| 0.75V |
|
|
|
|
| R = 50Ω | |||||||
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
| ||||||||||||
OUTPUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ALL INPUT PULSES[20] | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1.25V | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
DEVICE |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 pF 0.25V |
|
|
| 0.75V | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
UNDER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SLEW RATE= 2 V/ns | |||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
TEST ZQ |
|
|
|
|
|
| RQ = |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| 250Ω |
|
|
|
|
|
|
|
|
|
| ||
INCLUDING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
JIG AND |
|
|
|
|
|
| (b) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
SCOPE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note
20.Unless otherwise noted, test conditions are based on a signal transition time of 2V/ns, timing reference levels of 0.75V, VREF = 0.75V, RQ = 250Ω, VDDQ = 1.5V, input pulse levels of 0.25V to 1.25V, and output loading of the specified IOL/IOH and load capacitance shown in (a) of AC Test Loads and Waveforms.
Document Number: | Page 21 of 27 |
[+] Feedback