Cyclades PM IPDU manual List of Figures

Page 9

vii

LIST OF FIGURES

Figure 1.1: Standalone Configuration

3

Figure 1.2: Daisy Chained Configuration

4

Figure 1.3: The Cyclades PM IPDU with a Cyclades Management Device

5

Figure 1.4: Cyclades PM8 IPDU

7

Figure 1.5: Cyclades PM8i IPDU

8

Figure 1.6: Cyclades PM10 IPDU

8

Figure 1.7: Back of the Cyclades PM10iIPDU

9

Figure 1.8: Front of the Cyclades PM10iIPDU

9

Figure 1.9: The Cyclades PM20 IPDU

10

Figure 1.10: The Cyclades PM20i IPDU, PM20i-32A IPDU and PM20i-32AU IPDU

11

Figure 2.1: Rack Mounting a Cyclades PM10 IPDU, PM10l IPDU and PM8iIPDU

17

Figure 2.2: Rack Mounting Holes on the PM8i IPDU, PM10 IPDU and PM10i IPDU

18

Figure 2.3: PM10 IPDU with Mounting Brackets Installed

18

Figure 2.4: Rack Mount for the Cyclades PM8i IPDU, PM10 IPDU or PM10i IPDU

19

Figure 2.5: Connecting a Local Work Station to the Cyclades PM IPDU

21

Figure 3.1: Sending Firmware using HyperTerminal

28

Figure 3.2: Sending Firmware using Minicom

29

Figure C.1: PM10-L30A IPDU Circuit Breakers

80

Figure C.2: PM10i-L30A IPDU Circuit Breakers

80

Figure C.3: PM20-L30A IPDU Circuit Breakers

81

Figure C.4: PM20i-L30A IPDU, PM20i-32A IPDU and PM20i-32Au IPDU Circuit Breakers ....

82

Image 9
Contents Cyclades P M Ipdu FCC Warning Statement Canadian DOC Notice Cyclades PM Ipdu Power On Table of Contents Configuration Appendices Vi Cyclades PM Ipdu Installer/Administrator/User Guide List of Figures Viii Cyclades PM Ipdu Installer/Administrator/User Guide List of Tables Cyclades PM Ipdu Installer/Administrator/User Guide Features and Benefits Alarms and monitoringSequential power up Standalone configuration Hardware Configuration OptionsSupport for daisy chaining Creation of user accountsStandalone Configuration Daisy chained configurationUser Integrated configurationPM Ipdu #2 PM Ipdu #3 PM Ipdu #4 An integrated environment offers the following advantagesDirect console access Accessing the System ConsoleConsole access through a management device To connect a Cyclades PM Ipdu to an Avocent DSR switchCyclades PM8 Ipdu Component OverviewCyclades PM10 Ipdu Cyclades PM8i IpduCyclades PM10i Ipdu Cyclades PM10i-L30A IpduCyclades PM10i-32A Ipdu Cyclades PM10i-32Au Ipdu Cyclades PM20 IpduCyclades PM20i Ipdu Cyclades PM20i-32Au Ipdu Cyclades PM20i-32A IpduCyclades PM Ipdu Installer/Administrator/User Guide Supplied with the PM Ipdu Getting StartedConnector on Modular input power cables for the PM IpduPM8i-10A Ipdu and PM10i-10A Ipdu power cables PM10i-16A Ipdu and PM 20i-16A Ipdu power cables PM10i-15A Ipdu power cablesPM10i-20A Ipdu and PM 20i-20A Ipdu power cables Rack Mounting the Cyclades PM IpduRack Mounting a Cyclades PM10 IPDU, PM10l Ipdu and PM8iIPDU Installation environmentLocate the appropriate sets of holes on the PM Ipdu To mount the Cyclades PM8i IPDU, PM10 Ipdu or PM10i IpduTo daisy chain a PM Ipdu Daisy Chaining PM IPDUsMaking a Direct Connection for Console Access Powering Up the PM IpduTo power up the PM Ipdu Plugging Devices Into PM Ipdu OutletsConnecting a Local Work Station to the Cyclades PM Ipdu To access the consoleTo log into the PM Ipdu through the console in port Default Configuration Parameters ConfigurationTo change the default password Initial Configuration Using the Command PromptTo create users with the adduser command To assign outlets to users with the assign commandResetting the Admin Password To save the configuration with the save commandTo reset the admin password using the loopback connector Upgrading the Cyclades PM Ipdu Firmware To upgrade PM Ipdu firmwareTo use HyperTerminal in Windows PmupgradeTo use Minicom in Linux Sending Firmware using HyperTerminalSending Firmware using Minicom Cyclades PM Ipdu Installer/Administrator/User Guide PM Ipdu User Interface Daisy chained PM IPDUs in the login promptNumber of PM IPDUs Number of PM Ipdu outletsLogging in to the PM Ipdu CommandsSyntax AdduserArguments ExamplesAssign AlarmTo set the threshold, enter the following To read the threshold, enter the followingBuzzer CurrentTo turn buzzer notification on or off, enter the following Pmcurrent reset To reset maximum current drawn, enter the followingCurrentprotection Pm currentCurrseg ExampleTo view the current load of segment A, enter the following Cycle To view the current load of segment B, enter the followingTo cycle one outlet, enter the following Deluser DbsyncTo cycle multiple outlets, enter the following NoneTo delete the user rog, enter the following DisplayPmdeluser rog Pmdisplay 2Exit command exits the session FactorydefaultsExit To view the display status, enter the followingPmfactorydefaults To reset the factory defaults, enter the followingHelp Pmsyslog helpPmhelp HumidityPmhumidity reset HwocpPm humidity To set the ID of PM Ipdu 1 R&D, enter the following Pmhwocp 1 resetPmhwocp Pmid 1 R&DTo display the ID of PM Ipdu 2, enter the following IntervalTo display the interval of outlet 1, enter the following PmidList Pminterval 2,4-6Pmlist Name LockTo lock outlets 1, 2, and 6, enter the following To name outlet 4 as nowhere, enter the followingTo turn all outlets off, enter the following OffPmoff all PmoffPasswd To turn on outlets 1, 3, 4, and 5, typePmon 1 Reboot Pmpasswd alphaPmpasswd Pmreboot Pmrestore RestoreSave Arguments ExamplesStatus command displays the status of selected outlets To save the configuration to flash, enter the followingStatus To display the status of outlet 1, enter the followingTo display the status of all outlets, enter the following SyslogPmstatus all PmsyslogPm temperature TemperaturePmtemperature reset Pmsyslog onUnlock UnassignTo unlock outlets 2, 3, 4, and 8, enter the following Pmunassign 2,4 diderotUpgrade Ver To upgrade 1, typePmver VoltageWhoami To view the current username, enter the followingPmwhoami Cyclades PM Ipdu Installer/Administrator/User Guide Appendix a Specifications Cyclades PM Ipdu Installer/Administrator/User Guide Appendices Cyclades PM Ipdu Installer/Administrator/User Guide Appendices Table A.11 PM10i-32A Ipdu and PM10i-32Au Ipdu Specifications Table A.13 PM20-20A Ipdu and PM20-L20A Ipdu Specifications Cyclades PM Ipdu Installer/Administrator/User Guide Appendices Interface Pinouts Safety Instructions Appendix B Safety InstructionsSicherheitsanweisungen Istruzioni di Sicurezza Instruções de Segurança Instrucciones de seguridad Instructions de sécurités Appendix C Circuit Breakers PM Ipdu Units with One Circuit BreakerPM8i Ipdu and PM10i Ipdu PM10i-32A Ipdu and PM10i-32Au Ipdu PM10i-L30A IpduPM20i-L30A Ipdu PM20-L30A IpduPM20i-32A Ipdu and PM20i-32Au Ipdu Circuit Breaker Trip Time Cyclades PM Ipdu Installer/Administrator/User Guide Index Cyclades PM Installer/Administrator/User Guide Index Cyclades PM Installer/Administrator/User Guide Page 590-667-501A