2.1 %AANNTTCCFF
Description : Set module Configuration
Syntax : %AANNTTCCFF[CHK](cr)
%a delimiter character
AA address of setting module(00 to FF)
NNnew address for setting module(00 to FF)
TT new type for setting module (Ref Sec.1.10)
CC new baudrate for setting module (Ref Sec.1.10)
FF new data format for setting module (Ref Sec.1.10)
| When changing the baudrate or checksum, it is neces- | |
| sary to short the pin INIT* to ground. | |
Response : Valid Command : | !AA[CHK](cr) | |
| Invalid Command : | ?AA[CHK](cr) |
| Syntax error or communication error may get no re- | |
| sponse. |
|
! | delimiter for valid command |
?delimiter for invalid command. While change baudrate or checksum setting without shorting INIT* to ground, the
module will return invalid command.
AAaddress of response module(00 to FF) Example :
Command : %0102050600 Receive : !02 Change address from 01 to 02, return success.
Related Command :
Sec.2.7 $AA2
Related Topics :
Sec.1.10 Configuration Tables, Sec.3.1 INIT* pin Operation
22 | Rev:B1.0 |