INTERFACE: EIA-232C (CCITT V.24), -12v mark, +12v space. Optional EIA-422A (Option 17) and current loop (Option 12).

TRANSMISSION: Asynchronous.

FACTORY POWER-UP DEFAULT CONFIGURATIONS:

Baud rate: 9600.

Word size: 8 bits.

Parity: None.

Stop bits: 1.

XON/XOFF: Disabled.

Control character: Control-T (14 Hex).

Data block length: 32 characters.

Terminating character: Carriage Return (0D Hex).

Mode of operation: Mode 1 - Port expansion/sharing.

USER-PROGRAMMABLE CONFIGURATIONS:

Easy to configure using on-screen menus through the host port. Choices are saved in non-volatile memory to become the new power-up default configuration.

Baud rate: 110, 135, 300, 600, 1200, 2400, 4800, 9600. 19200 is available on the 525H only. Other rates optional.

Word size: 5, 6, 7 or 8 bits.

Parity: Even, odd or none.

Stop bits: 1, 1 1/2 or 2.

XON/XOFF: Enabled or disabled.

Control character: Any code from 00 Hex to 7F Hex.

Terminate character: Any code from 00 Hex to 7F Hex.

Data block length: 1 to 250 characters.

Mode of operation: 1 through 6.

4

Image 9
Contents Series Multiport Controllers Page Copyright 1993 by Bay Technical Associates, Inc Table of Contents Federal Communications Commission Radio Frequency Page Page Below shows six applications, one for each mode of operation USER-PROGRAMMABLE Configurations Factory POWER-UP Default ConfigurationsUL and CSA Listed Page Page Page DCE Port Signals 500H Series DCE to DTE Device Page Factory default is Carriage Return 0D Hex Page Page Page Page Page Page Page Page Host-to-multiport-to-peripheral communication Peripheral-to-multiport-to-host communication Host-to-multiport-to-peripheral communication Peripheral-to-multiport-to-host communication Page Operation Protocol Enter Port Number 0=Exit,Return For 110 135 300 600 1200 2400 4800 9600 Enter request 0AH Section Control Mode of Operation Main Menu SET Message Terminate Character TITC22*233343526Y130A4250*51466X Page Page Page Solutions Problem Garbage Data Symptom Missing Characters Symptom Random Garbage Characters Problem Cant Select Peripheral Port from Host Device Problem Cant Receive Data from Peripheral Ports Ccitt DOS Page Page Page Uart Other Baytech Products Page Page Series Multiport Controllers Page