NOTE: When changing the configuration of the host port, the multiport will also respond with:

Change Device to NEW Configuration

Before Answering This Request.

CAUTION: This message reminds you to change the serial port configuration of the host device to match the new configuration of the host port. If they do not match, the multiport will be unable to interpret the next command and you will be unable to access any multiport function. If this happens, cycle power on the multiport and reconfigure the unit. Make any necessary changes to host device before answering the "Save Changes Permanently?" prompt.

The multiport will now return to the main configuration menu (see Section 6.1).

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

By responding to the Enter Request: message at the end of the main configuration menu (see Section 6.1) with "3" (Set Message Terminate Character), you may set the message terminating character for Modes of Operation 2, 3, 4 and 5. The multiport will respond with:

Current Terminate Character is

0DH

Enter Terminate Character in Hex

:

Enter the terminating character that you wish in the form of a two-digit hexadecimal character (00 to 7F Hex). For example, if you enter 0A (Line Feed), the multiport will respond with:

Current Terminate Character is

0AH

Save Changes Permanently? (Y/N):

 

If you answer "Y" (yes), the new terminating character will be stored permanently in non-volatile memory and the multiport will subsequently power-up with the new terminating character in effect. If you answer "N" (no), the new terminating character will be stored in RAM and lost upon next power-up. The multiport will now return to the main configuration menu (see Section 6.1).

Image 34
Contents Series Multiport Controllers Page Copyright 1993 by Bay Technical Associates, Inc Table of Contents Federal Communications Commission Radio Frequency Page Page Below shows six applications, one for each mode of operation Factory POWER-UP Default Configurations USER-PROGRAMMABLE ConfigurationsUL and CSA Listed Page Page Page DCE Port Signals 500H Series DCE to DTE Device Page Factory default is Carriage Return 0D Hex Page Page Page Page Page Page Page Page Host-to-multiport-to-peripheral communication Peripheral-to-multiport-to-host communication Host-to-multiport-to-peripheral communication Peripheral-to-multiport-to-host communication Page Operation Protocol Enter Port Number 0=Exit,Return For 110 135 300 600 1200 2400 4800 9600 Enter request 0AH Section Control Mode of Operation Main Menu SET Message Terminate Character TITC22*233343526Y130A4250*51466X Page Page Page Solutions Problem Garbage Data Symptom Missing Characters Symptom Random Garbage Characters Problem Cant Select Peripheral Port from Host Device Problem Cant Receive Data from Peripheral Ports Ccitt DOS Page Page Page Uart Other Baytech Products Page Page Series Multiport Controllers Page