You may now reconfigure Port 3 by selecting the appropriate option (1-6) from the menu. For example, to change the baud rate to 2400 baud, send character "2" (Set baud rate). The multiport will respond with:

1

For

110

2

For

135

3

For

300

4

For

600

5

For

1200

6

For

2400

7

For

4800

8

For

9600

Enter request:

Enter "6" for 2400 baud rate, and the multiport will respond with the reconfigured status of the port and the menu of options:

•••••••••••••••••••••••••••••••••••••••••

Port •

Baud

Word

Stop

•Parity•Xon/•

Rate

Size

Bits

•Xoff•

•••••••••••••••••••••••••••••••••••••••••

• 3 • 2400 • 8 • 1 • None • Off•

•••••••••••••••••••••••••••••••••••••••••

Exit/Save

1

Set stop bits

4

Set

baud

rate

2

Set

parity

5

Set

word

size

3

Set

Xon/Xoff

6

Enter request:

If there are no other changes for this port, enter "1" (Exit/Save), and the multiport will respond with:

Save Changes Permanently? (Y/N):

If you answer "Y" (yes), the new configuration for that port will be stored permanently in non-volatile memory and the multiport will subsequently power-up at the new configuration. If you answer "N" (no), the new configuration will be stored in RAM and on the next power-up, the multiport will revert to the previous configuration.

28

Image 33
Contents Series Multiport Controllers Page Copyright 1993 by Bay Technical Associates, Inc Table of Contents Federal Communications Commission Radio Frequency Page Page Below shows six applications, one for each mode of operation USER-PROGRAMMABLE Configurations Factory POWER-UP Default ConfigurationsUL and CSA Listed Page Page Page DCE Port Signals 500H Series DCE to DTE Device Page Factory default is Carriage Return 0D Hex Page Page Page Page Page Page Page Page Host-to-multiport-to-peripheral communication Peripheral-to-multiport-to-host communication Host-to-multiport-to-peripheral communication Peripheral-to-multiport-to-host communication Page Operation Protocol Enter Port Number 0=Exit,Return For 110 135 300 600 1200 2400 4800 9600 Enter request 0AH Section Control Mode of Operation Main Menu SET Message Terminate Character TITC22*233343526Y130A4250*51466X Page Page Page Solutions Problem Garbage Data Symptom Missing Characters Symptom Random Garbage Characters Problem Cant Select Peripheral Port from Host Device Problem Cant Receive Data from Peripheral Ports Ccitt DOS Page Page Page Uart Other Baytech Products Page Page Series Multiport Controllers Page