Bay Technical Associates DS72 responds Requested Connection Made. Send the Ascii, Status

Page 15

DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

DS72 CONFIGURATION If you are using the Menu Selection Method, select C, “Configure,” followed by <cr> from the DS72 Main Menu. The following selection menu appears:

 

Configuration

 

 

Module 1

1

 

Module 2

2

 

Module 3

3

 

Select Port

S

 

Exit

X,CR

 

Enter request:

 

 

If you are using the ASCII Character String Method, exit the main menu,

 

then select the module to configure. To select Module #1, type $BT1<cr>.

 

The DS72 responds “Requested Connection Made.” Send the ASCII

 

configuration command $CONFIG. The configuration menu appears.

 

Enter the number of the module to configure, followed by <cr>. To

 

configure the host module 1, select #1. The following configuration menu

 

appears for the DS72:

 

 

Copyright(C) Bay Technical Associates 1998

 

DS-72 Data Switch Series - Telnet Host Module

 

Revision F.1.00

 

 

Module 1

 

 

Status

1

 

Serial Port Configuration

2

 

Port Device Name

3

 

Port Select Code

4

 

Attention Character

5

 

Disconnect Timeguard

6

 

Connect Port ID Echo

7

 

Login Setup

8

 

Network Port Configuration

9

 

Unit ID

10

 

Configure Another Module

11

 

Exit

X,CR

 

Enter Request:

 

STATUS

View the status of most user

programmable features by selecting #1,

 

“Status,” from the configuration menu, followed by <cr>. The following

 

menu appears:

 

 

Installed Modules :

 

 

Port Select Code is

$BT

 

Attention Character is

;

 

Disconnect Time Guard is

Enabled

 

Port ID Echo is

Device Name

 

Unit ID is

BAYTECH DS72

 

Network Setup :

 

 

Ethernet Address

00.C0.48.06.1A.81

 

IP Address

200.4.2.65

 

Subnet Mask

255.255.255.0

 

Gateway

200.4.2.1

 

Inactivity Timeout (mins)

1

 

Break Length (msecs)

350

10

Image 15
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Introduction to the DS72 Network Interface Module Programmable Features of the DS72DSU Control Port Access PowerGetting Started DS72 Quick StartEnter IP address in dotted decimal form Unpacking InstallationPreparing the Installation Site PowerRJ-45 Cables and Adapters DS72 EIA-232 RJ-45 Pin/Signal DefinitionPin EIA-232 Description Signal CablingCabling Detailed Operation and Configuration Accessing MainMenu Binary Mode $BT2,1cr$BTBcr Terminate BinaryMode DS72 responds Requested Connection Made. Send the Ascii Appears for the DS72Status For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Default Port Select Code is $BT Port SelectCode Connect Port CharacterDisconnect Time GuardLogin Setup Default Header is enabledHeader Menu PasswordAuto Connect Port If enabled, the following header and menu appearsIP Address Auto Connect Port is disabledConfiguration Network PortBefore the DS-Series can be accessed through the network Subnet MaskGateway Unit ID Logged Users Unit ResetSystem NetworkIndication Interpretation DiagnosticsAscii CharacterTechnical Support REPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Radio Frequency Interface Statement DS72 Network Interface Module SpecificationsAppendix B Fixed Serial Port Rate defaultAppendix B Break condition Index