Bay Technical Associates DS72 owner manual If enabled, the following header and menu appears

Page 22

DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

If enabled, the following header and menu appears:

Bay Technical Associates

Unit ID: BAYTECH DS72

Port Select Code: $BT

 

Attention Character: ;

 

Device A

(2,1)

1

Device B

(2,2)

2

Device C

(2,3)

3

Device D

(2,4)

4

DS-RPC

(3,1)

5

Configure

C

Status

S

I/O Modules Reset

RM

Unit Reset

RU

Exit

X

Logout

T

To toggle the menu status, select #3, “Menu,” from the selection menu, followed by <cr>. The DS72 module displays the current status and asks if you want to change:

 

Menu is

Disabled

 

Enable? (Y/N, CR for no change):

 

Type “Y” followed by <cr>

if you want to enable Menu. Type “N”

 

followed by <cr> if you want to disable Menu. Type <cr> for no change.

Auto Connect Port

If Auto Connect Port has

been enabled, establishing a communication

 

link to the DS72 module will connect the user to the designated I/O port.

 

This also happens when a connection is established via the serial port.

NOTE: The auto connect port has priority over the login setup menu. If Auto Connect Port is enabled, the main menu is automatically disabled.

Select # 4, “Auto Connect Port”, from the selection menu, followed by <cr>.

The following Auto Connect Port menu appears:

Auto Connect Port is

Module 3,Port 1

Auto Connect is

Disabled

Change Auto Connect Port

1

Enable/Disable

2

Exit

X,CR

Enter Request :

 

The DS72 module displays the current auto connect port and its current status. To change the auto connect port module number and port number, select #1, “Change Auto Connect Port,” followed by <cr>. The DS72 module responds:

Auto Connect Port is..............Module 3,Port 1

Enter Auto Connect Module (2 to 9) :3

Enter Auto Connect Port (1 to 4) :1

Auto Connect Port is

Module 3,Port 1

17

Image 22
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Programmable Features of the DS72 Introduction to the DS72 Network Interface ModuleControl Port Access Power DSUDS72 Quick Start Getting StartedEnter IP address in dotted decimal form Power InstallationPreparing the Installation Site UnpackingCabling DS72 EIA-232 RJ-45 Pin/Signal DefinitionPin EIA-232 Description Signal RJ-45 Cables and AdaptersCabling Accessing Main Detailed Operation and ConfigurationMenu $BT2,1cr$BTBcr Terminate Binary Binary ModeMode Appears for the DS72 DS72 responds Requested Connection Made. Send the AsciiStatus For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Port Select Default Port Select Code is $BTCode Guard CharacterDisconnect Time Connect PortDefault Header is enabled Login SetupHeader Password MenuIf enabled, the following header and menu appears Auto Connect PortNetwork Port Auto Connect Port is disabledConfiguration IP AddressSubnet Mask Before the DS-Series can be accessed through the networkGateway Unit ID Network Unit ResetSystem Logged UsersCharacter DiagnosticsAscii Indication InterpretationTechnical Support Call BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryFCC Radio Frequency Interface Statement Specifications DS72 Network Interface ModuleFixed Serial Port Rate default Appendix BAppendix B Index Break condition