Bay Technical Associates DS72 Ascii, Character, Diagnostics, Indication Interpretation

Page 27

 

 

 

 

DS72 HOST MODULE OWNER’S MANUAL

 

 

 

 

DETAILED OPERATION AND CONFIGURATION

 

 

 

 

 

 

 

Allow approximately 10 seconds for the unit to reset.

ASCII

To reset the DS-Series Unit using the ASCII character string method,

Character

send the following command:

String

 

 

 

 

 

 

$BTRESET<cr>

 

 

DIAGNOSTICS

To detect hardware, cabling, or configuration problems upon initialization

 

 

of power, the DS72 executes a diagnostic sequence. To help determine

 

 

the cause of the problem, the DS72 has a CX LED located on the front

 

 

panel of the unit. Upon initialization of power, refer to the following table

 

 

for interpretation.

 

 

 

 

 

 

 

 

INDICATION

 

INTERPRETATION

 

 

 

 

 

 

 

 

Not lit

 

 

Normal unconnected operation

 

 

 

 

 

 

 

Brief flash followed by a solid illumination

 

Established connection on network port or serial port

 

 

 

 

 

 

 

 

Flashes 1 time per cycle

 

 

Hardware or NIC problem

 

 

 

 

 

 

 

 

Flashes 2 times per cycle

 

 

Configuration error

 

 

 

 

 

 

 

 

Flashes 3 times per cycle

 

 

Cable or hub connection fault

 

 

 

 

 

 

 

 

Flashes 4 times per cycle

 

 

Duplicate IP address

 

 

 

 

 

 

 

Remains lit without a brief flash prior to

 

Memory error

 

 

illumination

 

 

 

 

NOTE: Diagnostic indications override a connection indication.

22

Image 27
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Introduction to the DS72 Network Interface Module Programmable Features of the DS72DSU Control Port Access PowerGetting Started DS72 Quick StartEnter IP address in dotted decimal form Unpacking InstallationPreparing the Installation Site PowerRJ-45 Cables and Adapters DS72 EIA-232 RJ-45 Pin/Signal DefinitionPin EIA-232 Description Signal CablingCabling Detailed Operation and Configuration Accessing MainMenu Binary Mode $BT2,1cr$BTBcr Terminate BinaryMode DS72 responds Requested Connection Made. Send the Ascii Appears for the DS72Status For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Default Port Select Code is $BT Port SelectCode Connect Port CharacterDisconnect Time GuardLogin Setup Default Header is enabledHeader Menu PasswordAuto Connect Port If enabled, the following header and menu appearsIP Address Auto Connect Port is disabledConfiguration Network PortBefore the DS-Series can be accessed through the network Subnet MaskGateway Unit ID Logged Users Unit ResetSystem NetworkIndication Interpretation DiagnosticsAscii CharacterTechnical Support REPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Radio Frequency Interface Statement DS72 Network Interface Module SpecificationsAppendix B Fixed Serial Port Rate defaultAppendix B Break condition Index