Bay Technical Associates DS72 owner manual Login Setup, Default Header is enabled

Page 20

DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

by <cr>. The DS72 module presents the current status of Port ID Echo and asks if you want to change:

Port ID Echo is

Disabled

Change It? (Y/N):

 

Type “Y” followed by <cr> to toggle Connect Port ID Echo or “N” for no followed by <cr>. If you answer yes, the DS72 module responds:

Port ID Echo is

Device Name

Disable Port ID Echo

1

Use Module, Port Number

2

Use Device Name

3

Exit

X,CR

Enter Request :

 

If you are enabling Port ID Echo, choose #2 to echo the module and port number, followed by <cr>. Choose #3 to echo the device name, followed by <cr>. The DS72 module stores the selected Connect Port ID Echo in non- volatile memory and returns to the configuration menu.

NOTE: If you choose #3, “Use Device Name,” the programmed Port Device Name for the selected DS74 is used.

LOGIN SETUP

This configures how

the DS72 responds upon login.

You can

 

Enable/Disable the Header and Menu and/or Enable/Disable/Program

 

Password and Auto Connect Port.

 

 

From the configuration menu, select #8, “Login Setup,” followed by <cr>.

 

The following menu appears:

 

 

Header

1

 

 

Password

2

 

 

Menu

3

 

 

Auto Connect

4

 

 

Exit

X,CR

 

 

Enter Request :

 

 

Header

If enabled, the following header appears with the main menu upon initiation

 

of power or after a modem connection to the host module has been

 

established. If disabled, the header does not appear with the main menu.

 

Default Header is enabled.

 

 

Data Switch Series – F.1.00

 

 

Bay Technical Associates

 

 

Unit ID: BAYTECH DS72

 

 

 

Port Select Code: $BT

 

 

Attention Character:

;

 

From the selection menu, select #1, “Header,” followed by <cr>. The DS72 displays the current header status and asks if you want to enable:

15

Image 20
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Programmable Features of the DS72 Introduction to the DS72 Network Interface ModuleControl Port Access Power DSUDS72 Quick Start Getting StartedEnter IP address in dotted decimal form Installation Preparing the Installation SitePower UnpackingDS72 EIA-232 RJ-45 Pin/Signal Definition Pin EIA-232 Description SignalCabling RJ-45 Cables and AdaptersCabling Menu Detailed Operation and ConfigurationAccessing Main Mode Binary Mode$BT2,1cr$BTBcr Terminate Binary Status DS72 responds Requested Connection Made. Send the AsciiAppears for the DS72 For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Code Default Port Select Code is $BTPort Select Character Disconnect TimeGuard Connect PortHeader Login SetupDefault Header is enabled Password MenuIf enabled, the following header and menu appears Auto Connect PortAuto Connect Port is disabled ConfigurationNetwork Port IP AddressGateway Before the DS-Series can be accessed through the networkSubnet Mask Unit ID Unit Reset SystemNetwork Logged UsersDiagnostics AsciiCharacter Indication InterpretationTechnical Support Call BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryFCC Radio Frequency Interface Statement Specifications DS72 Network Interface ModuleFixed Serial Port Rate default Appendix BAppendix B Index Break condition