Bay Technical Associates owner manual DS72 Quick Start, Getting Started

Page 8

DS72 HOST MODULE OWNER’S MANUAL

DS72 QUICK START

DS72 QUICK START

This section describes the basic steps required to set up and configure your DS72. If you need to acquaint yourself further with the setup, configuration, and operations, see “Detailed Operations and Configuration” beginning on page 8.

GETTING STARTED

Before the DS72 can be used within a network, there are a few parameters which must be configured.

For an initial setup, connect the serial port of your computer to the RJ-45 port labeled “EIA-232” on the DS72 module using the 9FRJ45PC-4 adapter and the RJ08X007 (8 pin crossed) cable.

With standard serial communications software or a terminal, set serial communications parameters to 9600 bps, 8 data bits, 1 stop bit, and no parity. This will allow direct communications with the DS72 module. Apply power to the DS-Series unit. The following main menu will appear:

Data Switch Series - F.1.00

Bay Technical Associates

Unit ID: BAYTECH DS72

Port Select Code: $BT

 

 

Attention Character: ;

 

 

Device A

(2,1)

1

 

Device B

(2,2)

2

 

Device C

(2,3)

3

 

Device D

(2,4)

4

 

DS-RPC

(3,1)

5

(if connected in a DS-RPC unit)

Configure

C

 

Status

S

 

I/O Modules Reset

RM

 

Unit Reset

RU

 

Exit

X

 

Logout

T

 

Enter Request :

NOTE: Depending on the DS series or DS-RPC model, the menus may vary according to the number of DS74 modules installed in the unit.

At a minimum, the IP Address, Subnet Mask and Gateway must be programmed in order to access the unit via your network. At the “Enter Request:” prompt, type “C” followed by <cr>. The following menu is displayed:

3

Image 8
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Programmable Features of the DS72 Introduction to the DS72 Network Interface ModuleControl Port Access Power DSUDS72 Quick Start Getting StartedEnter IP address in dotted decimal form Installation Preparing the Installation SitePower UnpackingDS72 EIA-232 RJ-45 Pin/Signal Definition Pin EIA-232 Description SignalCabling RJ-45 Cables and AdaptersCabling Menu Detailed Operation and ConfigurationAccessing Main Mode Binary Mode$BT2,1cr$BTBcr Terminate Binary Status DS72 responds Requested Connection Made. Send the AsciiAppears for the DS72 For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Code Default Port Select Code is $BTPort Select Character Disconnect TimeGuard Connect PortHeader Login SetupDefault Header is enabled Password MenuIf enabled, the following header and menu appears Auto Connect PortAuto Connect Port is disabled ConfigurationNetwork Port IP AddressGateway Before the DS-Series can be accessed through the networkSubnet Mask Unit ID Unit Reset SystemNetwork Logged UsersDiagnostics AsciiCharacter Indication InterpretationTechnical Support Call BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryFCC Radio Frequency Interface Statement Specifications DS72 Network Interface ModuleFixed Serial Port Rate default Appendix BAppendix B Index Break condition