Bay Technical Associates DS72 owner manual Iii

Page 3

DS72 HOST MODULE OWNER’S MANUAL

ABOUT THIS OWNER’S MANUAL

ABOUT THIS OWNER’S MANUAL

This document provides information required for installing and operating your Bay Tech equipment. It should allow the user to connect, power up, and access an applications menu where peripheral equipment can be controlled. We recommend reading this manual carefully, while placing special emphasis on correct cabling and configuration. If you have any problems with your installation, please contact a BayTech Applications Engineer at 228-467-8231, call toll free from anywhere in the United States using 1-800-523-2702or contact us at our Web Site, www.baytechdcd.com.

BayTech manufactures many remote site management products, data switches, data collection multiplexers, remote power controllers, and peripheral print sharers. If you would like information on any of these products, please contact BayTech Customer Service at the numbers previously listed.

Conventions used in this manual include:

CAUTION: This term is used to denote any condition that could possibly result in physical harm to personnel or damage to equipment.

IMPORTANT: This term is used to denote conditions that could result in the loss of communications or to highlight the proper functioning of equipment.

NOTE: This term is used to denote items of interest to the user.

<cr>: Carriage Return or ENTER

The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Bay Technical Associates, Inc.

In the interest of improving internal design, operational function, and/or reliability, Bay Technical Associates, Inc reserves the right to make changes to the products described in this document without notice.

Bay Technical Associates, Inc does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.

We welcome any comments you may have about our products, and we hope that you will continue to look to BayTech for your data communication needs.

iii

Image 3
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Introduction to the DS72 Network Interface Module Programmable Features of the DS72DSU Control Port Access PowerGetting Started DS72 Quick StartEnter IP address in dotted decimal form Unpacking InstallationPreparing the Installation Site PowerRJ-45 Cables and Adapters DS72 EIA-232 RJ-45 Pin/Signal DefinitionPin EIA-232 Description Signal CablingCabling Detailed Operation and Configuration Accessing MainMenu Binary Mode $BT2,1cr$BTBcr Terminate BinaryMode DS72 responds Requested Connection Made. Send the Ascii Appears for the DS72Status For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Default Port Select Code is $BT Port SelectCode Connect Port CharacterDisconnect Time GuardLogin Setup Default Header is enabledHeader Menu PasswordAuto Connect Port If enabled, the following header and menu appearsIP Address Auto Connect Port is disabledConfiguration Network PortBefore the DS-Series can be accessed through the network Subnet MaskGateway Unit ID Logged Users Unit ResetSystem NetworkIndication Interpretation DiagnosticsAscii CharacterTechnical Support REPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Radio Frequency Interface Statement DS72 Network Interface Module SpecificationsAppendix B Fixed Serial Port Rate defaultAppendix B Break condition Index
Related manuals
Manual 38 pages 49.39 Kb