DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

Enter the Module IP Address (Example: 200.4.3.50), followed by <cr>. The DS72 resumes the configuration menu.Default Module IP Address is 0.0.0.0.

If you fail to enter the Module IP Address in dotted decimal form, the

DS72 responds again:

Enter Module IP address in dotted decimal form:

The DS72 responds indefinitely with the same request until the Module IP

Address in entered in the correct form.

NOTE: There should be no active connections while configuring the DS72 module. The unit should be reset upon completion of configuration.

Subnet Mask

The Subnet Mask is a bit mask that identifies the network portion of the IP

 

address, allowing the DS72 to determine whether to send a packet directly

 

to the client or to a gateway. The Subnet Mask consist of four bytes, each

 

byte ranging from 0 to 255. This parameter must be programmed

 

before the DS-Series can be accessed through the network.

 

From the configuration menu, select #2, “Subnet Mask,” followed by

 

<cr>. The DS72 responds:

 

Enter Subnet Mask in dotted decimal form:

 

Enter the Subnet Mask (Example: 255.255.255.0), followed by <cr>. The

 

DS72 resumes the configuration menu. Default Subnet Mask is 0.0.0.0.

 

If you fail to enter the Subnet Mask in dotted decimal form, the DS72

 

responds again:

 

Enter Subnet Mask in dotted decimal form:

 

The DS72 responds indefinitely with the same request until the Subnet

 

Mask is entered in the correct form.

Gateway

The Gateway is the address of a router for connection to their networks.

 

The Gateway address consists of four bytes, each byte ranging from 0 to

 

255. If your network uses gateways, this parameter must be programmed

 

before the DS72 can be accessed through a network.

 

From the configuration menu, select #3, “Gateway,” followed by <cr>.

 

The DS72 responds:

 

Enter Gateway address in dotted decimal form:

Enter the Gateway address (Example: 200.4.5.50), followed by <cr>. The

DS72 resumes the configuration menu. Default Gateway address is

0.0.0.0.If you fail to enter the Gateway address in dotted decimal form, the DS72 responds again:

19

Image 24
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Programmable Features of the DS72 Introduction to the DS72 Network Interface ModuleControl Port Access Power DSUDS72 Quick Start Getting StartedEnter IP address in dotted decimal form Installation Preparing the Installation SitePower UnpackingDS72 EIA-232 RJ-45 Pin/Signal Definition Pin EIA-232 Description SignalCabling RJ-45 Cables and AdaptersCabling Detailed Operation and Configuration Accessing MainMenu Binary Mode $BT2,1cr$BTBcr Terminate BinaryMode DS72 responds Requested Connection Made. Send the Ascii Appears for the DS72Status For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Default Port Select Code is $BT Port SelectCode Character Disconnect TimeGuard Connect PortLogin Setup Default Header is enabledHeader Password MenuIf enabled, the following header and menu appears Auto Connect PortAuto Connect Port is disabled ConfigurationNetwork Port IP AddressBefore the DS-Series can be accessed through the network Subnet MaskGateway Unit ID Unit Reset SystemNetwork Logged UsersDiagnostics AsciiCharacter Indication InterpretationTechnical Support Call BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryFCC Radio Frequency Interface Statement Specifications DS72 Network Interface ModuleFixed Serial Port Rate default Appendix BAppendix B Index Break condition