DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

Enter the module to connect automatically, followed by <cr>. Enter the port to connect automatically, followed by <cr>. The DS72 module stores the new settings in non-volatile memory and returns to the Auto Connect Port menu.

Toggle Auto Connect Port feature by selecting #2, “Enable/Disable,” from the Auto Connect Port menu followed by <cr>. The DS72 module displays the current auto connect port status and asks if you want to enable. Default

Auto Connect Port is disabled.

Auto Connect is

Disabled

Type “Y” followed by <cr> if you want to enable Auto Connect Port. Type “N” followed by <cr> if you want to disable Auto Connect Port. Type <cr> for no change. The DS72 module stores Auto Connect Port configuration in non-volatile memory and returns to the Auto Connect Port menu.

NETWORK PORT

This sets up the network parameters for the DS72.

CONFIGURATION

 

 

 

 

From the configuration menu, select #9, “Network Port Configuration”,

 

followed by <cr>. The following menu appears:

 

Network Configuration

 

 

IP Address:

200.4.2.65

 

 

Subnet Mask: 255.255.255.0

 

 

Gateway:

200.4.2.1

 

 

Ethernet Address: 00.C0.48.06.1A.81

 

Connection Inactivity Timeout (mins): 1

 

Carriage Return Translation: Disabled

 

Break Length (msecs): 350

 

 

IP Address

1

 

Subnet Mask

2

 

Gateway

3

 

Activity Timeout

4

 

Carriage Return Translation

5

 

Break Length

6

 

Exit

X,CR

 

Enter Request :

 

IMPORTANT: For network access, you must configure the IP addresses, Subnet Mask, and Gateway Address. The module must be reset for network changes to take effect.

IP Address

The IP address is the network address assigned by your network manager

 

for your network.The IP Address consist of four bytes, each byte ranging

 

from 0 to 255. This parameter must be programmed before the DS72

 

may be accessed via the network.

 

From the configuration menu, select #1, “IP Address,” followed by <cr>.

 

The DS72 responds:

 

Enter Module IP address in dotted decimal form:

18

Image 23
Contents BayTech Manual Publication #U140A127 October Page Iii Table of Contents REPACKAGING, Shipping and Returning to the Factory Introduction to the DS72 Network Interface Module Programmable Features of the DS72DSU Control Port Access PowerGetting Started DS72 Quick StartEnter IP address in dotted decimal form Unpacking InstallationPreparing the Installation Site PowerRJ-45 Cables and Adapters DS72 EIA-232 RJ-45 Pin/Signal DefinitionPin EIA-232 Description Signal CablingCabling Menu Detailed Operation and ConfigurationAccessing Main Mode Binary Mode$BT2,1cr$BTBcr Terminate Binary Status DS72 responds Requested Connection Made. Send the AsciiAppears for the DS72 For For 57.6K a for 76.8K B for 115.2K Enter Request Name is EIA-232 Code Default Port Select Code is $BTPort Select Connect Port CharacterDisconnect Time GuardHeader Login SetupDefault Header is enabled Menu PasswordAuto Connect Port If enabled, the following header and menu appearsIP Address Auto Connect Port is disabledConfiguration Network PortGateway Before the DS-Series can be accessed through the networkSubnet Mask Unit ID Logged Users Unit ResetSystem NetworkIndication Interpretation DiagnosticsAscii CharacterTechnical Support REPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberFCC Radio Frequency Interface Statement DS72 Network Interface Module SpecificationsAppendix B Fixed Serial Port Rate defaultAppendix B Break condition Index