AVE VSI-PRO operation manual Connections, VSI-Pro Rear Panel

Page 10

CONNECTIONS

3. CONNECTIONS

The VSI-Pro will overlay the characters on any input video source. The video input can be virtually any baseband or composite video source. The VSI-Pro will accept NTSC, RS-170, RS-330, CCIR, PAL or SECAM video formats.

The Video input to the VSI-Pro is a standard BNC connector, terminated at 75 [ohms].

NOTE ?

The input video level must be 1[V] Peak to Peak. If this level is not maintained within +/- 20%, the VSI-Pro will have difficulty locking the character display over the input video source.

After completing the interface installation as described in the separate Installation Guide for your specific cash register,computer, radar gun or other serial device, connect the video input source to the video input BNC on the rear of the VSI-Pro. The BNC video output goes out to the video system (VCR, DVR, quad, switcher, multiplexer, or monitor). This connection is shown in Figure 3. The video output from the VSI-Pro is 1[V] Peak to Peak into a 75 [ohm] load. Most monitors or televisions with direct video inputs are terminated with a 75 ohm load. If the monitor is not terminated, the VSI-Pro will still output 1[V] Peak to Peak. The VSI-Pro will be able to drive two terminated loads without loss of video level.

NOTE ?

The VSI-Pro will not enter the programming mode unless it is connected to a video source.

Included with the VSI-Pro is a 9 VDC @300 [mA] UL/CSA power supply which must be plugged into the Power input on the VSI-Pro’s Real Panel.

Figure 2: VSI-Pro Rear Panel

Serial Input Power Video Input Video Output

Figure 3: VSI-Pro Cable Connections

VSI-Pro VIDEO SERIAL INTERFACE

10

Image 10
Contents VSI-PRO JuneVSI-Pro Contents Contents Gasboy Sub-Menu Download/Upload Sub-Menu Introduction VSI / VSI+ / VSI-Pro Backward CompatibilityFeatures & Specifications FeaturesFeatures & Specifications SpecificationsConnections VSI-Pro Rear PanelDTR PIN # Signal Name RS232PIN # Function Direction DSRVSI-PRO VSI-Pro ConnectionsUser Front Panel Controls Front Panel ControlsChanging the Horizontal Position Main Programming Menu ProgrammingGetting Started Register SelectNext page Exit TCP/IP LimitationsDisplay Receipt Exit SET Address ANY ExitSET Address DisplayDevice CON Sole Device Address Exit ModelDisplay Journal Exit DeviceLocal VSS Micros IDN Network Micros ISN Network Exit Operator Customer Combined ExitJournal Receipt Check Credit Exit Device Printer Device Address ANY Modetap ExitWoking Mode Title Display on Console ID ANY Working Mode ExitModel Working Mode Exit NCR Jrnl Printer NCR Rcpt Printer NCR Slip PrinterDevice Address ANY Address Exit Model TK-T500 Mode Emulating ExitDevice Address Exit Next page ExitJournal Printer Receipt Printer SET Term noChoices ALL, 1, 2, 3,..., 253, 254 Choices RECEIPT, CDU 2L , C.D.UText Grayscale Screen SetupBackground Grayscale Clock Sub-Menu Title Text DisplayTitler OFF Exit Screen Blank Display Lines Display FormatScreen Blank Choices NONE, 6, 12, 20, 30, 60, 120, 180Line Compress Left JustificationRS-232 CommunicationInterface Type Choices RS-232, Passive TAP, RS-485Choices 7 or Exception ReportsChoices NONE, ODD, Even Exception Report OverviewON-SCREEN Flags Hard Alarm OutputPrinter or DVR Output Total Exception Exception History SET Exception Output Time Stamp ExitException History Total ExceptionsDest ID SCR ID Exit Time Search Time Search SettingDMS-3001 DVR-3011.3021 Choices 1 throughExample Operator None Exit 0000.00Exception no History Buffer ON/OFF Scroll Matching Exception Strings ON/OFFProgramming Note Negative ExceptionPage Greater than OUT RangeLess than Exception Report Menu Output Alarm OutputsAlarm no Triggered Text ExitNormal State RTSChoices no Normally open, NC Normal closed Display Text OFF Output Text SET Triggered Exit Choices 6, 12, 30, 60, 120, 180Triggered Text Display TextDisplay Text OFF Output Text SET Triggered Text Exit TEST/DEMO ModeSET Triggered Text Port 1 Test Data Capture Register Demo Version ID ExitPort 1 Test Receive RX TestRX / TX Test RX /TX Test DisplayRX Baudrate Auto TX Baudrate Capture to Port Capture to Memory Dump Memory ExitCapture to Port 2400VSI-PRO Version 13.00R19 03/25/2008 DOWNLOAD/UPLOAD SetupDemo Demo on Power UP OFF Exit DOWNLOAD/UPLOAD Data CableDOWNLOAD/UPLOAD Setup Using VSI-PRO to VSI-PRO DOWNLOAD/UPLOAD Setup Using VSI-Pro to VSI-ProDownload Setup Upload Setup Update Firmware Exit Download Setup Upload Setup ExitSoftware Installation DOWNLOAD/UPLOAD Setup Using a PCVSI-Pro Remote Program Downloading Ver Click the Tab Remote and you will see the following Menu Figure P2 Remote MenuCommunication Cable Pin Out File MenuAbout Menu PC / Laptop VSI-ProVSI-Pro Firmware Download Menu VSI-Pro Firmware Download UtilityFigure P6 Connect To Menu Figure P8 In-System Programming Display Problem Solving Guide Appendix aAppendix a Problem Solving GuideHOW to do a Master Reset on VSI-PRO Characters JITTER, JUMP, or SkewFront Panel PC-BASED Cash RegisterAppendix B TXD RXD GNDDVR Appendix COther RS-485 Network Appendix CDB-9 Pin-Out RJ-45 Pin-Out Physical Characteristics RS-485 Network Data Cable WiringElectrical Characteristics RS-232 ParametersHydra / Regcom Front Panel Hydra / Regcom Rear PanelAppendix D RS-485 NetworkerAppendix E Appendix FRS-485 Vnetworker RS-485 VnetworkerFigure Vnetworker Connection Diagram Vnetworker Software Figure Time / Date Set up Menu Remote Keyboard Vsib DB-9M VSI-Pro DB-9M Vsib InstallationAppendix G TXD RXD RTS CTS GNDECR Interface Cards Appendix HTcpip 232 Adapter AppendixTcpip 232 Adapter Tcpip DB-9MHard Alarm Output Appendix JAppendix K VSI-Pro Version 13.00 Register Select MenuRegister Select Appendix KVSI-Pro Version 13.24 Register Select Menu Master Reset Appendix LLimited Warranty Appendix MLimited Warranty Appendix NNorth America