AVE Comprehensive Guide to VSI Pro Cash Register and Networker Software

Page 63

PC SOFTWARE with CASH REGISTER

APPENDIX E

The simple to install and use the Networker PC Software allows up to 64 VSI-Pros and Cash Registers to be config- ured on an RS-485 network and report all the transaction data back to a single monitoring computer. This Windows- based software can be configured to display in a windowing horizontal format below or tiling in a vertical format. All data files are stored separately as independent files on the PC and can be downloaded or searched locally or remotely to find specific transaction data or information. This can be used in conjuction with Windows-based DVR or Cash Register software and eliminates the use of an additional PC for the collection, search, or transmission.

WINDOWS TILE HORIZONTAL

Figure1E : Windows Tile Horizontal

APPENDIX F

RS-485 VNETWORKER

RS-485 VNETWORKER

The Vnetworker is an enhancement to the Networker product and software to allow a PC to remotely control, program and upload register data from up to 16 VSI-Pros on a single RS-485 network. The Vnetworker products connects to the cash register, the VSI-Pro and the RS-485 networker and controls the flow of data from all de- vices. This device utilitzes the “Hardware” handshaking RTS line of the VSI-Pro to control reading register data and signally the VSI-Pro that the user requires programming upload. The programming upload is user interactive remotely similar to pressing the front panel controls of the VSI-Pro and changing the on-screen menus. However most functions can be done remotely on the PC without looking at the monitor view of the menus and camera view. This feature is only available on VSI-Pro Ver. 13.XX Release 12 or higher. All Version 13.XX can be factory upgraded to support this feature.

Figure : Vnetworker Front Panel

Figure : Vnetworker Rear Panel

 

 

VSI-Pro VIDEO SERIAL INTERFACE

63

Image 63
Contents June VSI-PROVSI-Pro Contents Contents Gasboy Sub-Menu Download/Upload Sub-Menu VSI / VSI+ / VSI-Pro Backward Compatibility IntroductionFeatures Features & SpecificationsSpecifications Features & SpecificationsVSI-Pro Rear Panel ConnectionsDSR PIN # Signal Name RS232PIN # Function Direction DTRVSI-Pro Connections VSI-PROFront Panel Controls User Front Panel ControlsChanging the Horizontal Position Register Select ProgrammingGetting Started Main Programming MenuTCP/IP Limitations Next page ExitDisplay SET Address ANY ExitSET Address Display Receipt ExitDevice ModelDisplay Journal Exit Device CON Sole Device Address ExitDevice Printer Device Address ANY Modetap Exit Operator Customer Combined ExitJournal Receipt Check Credit Exit Local VSS Micros IDN Network Micros ISN Network ExitNCR Jrnl Printer NCR Rcpt Printer NCR Slip Printer Title Display on Console ID ANY Working Mode ExitModel Working Mode Exit Woking ModeNext page Exit Model TK-T500 Mode Emulating ExitDevice Address Exit Device Address ANY Address ExitChoices RECEIPT, CDU 2L , C.D.U SET Term noChoices ALL, 1, 2, 3,..., 253, 254 Journal Printer Receipt PrinterScreen Setup Text GrayscaleBackground Grayscale Clock Sub-Menu Screen Blank Display Lines Display Format Text DisplayTitler OFF Exit TitleChoices NONE, 6, 12, 20, 30, 60, 120, 180 Screen BlankLeft Justification Line CompressChoices RS-232, Passive TAP, RS-485 CommunicationInterface Type RS-232Exception Report Overview Exception ReportsChoices NONE, ODD, Even Choices 7 orHard Alarm Output ON-SCREEN FlagsPrinter or DVR Output Total Exceptions Exception History SET Exception Output Time Stamp ExitException History Total ExceptionChoices 1 through Time Search Time Search SettingDMS-3001 DVR-3011.3021 Dest ID SCR ID ExitExample 0000.00 Operator None ExitException no Scroll Matching Exception Strings ON/OFF History Buffer ON/OFFNegative Exception Programming NotePage OUT Range Greater thanLess than Triggered Text Exit Alarm OutputsAlarm no Exception Report Menu OutputRTS Normal StateChoices no Normally open, NC Normal closed Display Text Choices 6, 12, 30, 60, 120, 180Triggered Text Display Text OFF Output Text SET Triggered ExitPort 1 Test Data Capture Register Demo Version ID Exit TEST/DEMO ModeSET Triggered Text Display Text OFF Output Text SET Triggered Text ExitReceive RX Test Port 1 TestRX /TX Test Display RX / TX Test2400 Capture to Port Capture to Memory Dump Memory ExitCapture to Port RX Baudrate Auto TX BaudrateDOWNLOAD/UPLOAD Data Cable DOWNLOAD/UPLOAD SetupDemo Demo on Power UP OFF Exit VSI-PRO Version 13.00R19 03/25/2008DOWNLOAD/UPLOAD Setup Using VSI-Pro to VSI-Pro DOWNLOAD/UPLOAD Setup Using VSI-PRO to VSI-PRODownload Setup Upload Setup Exit Download Setup Upload Setup Update Firmware ExitDOWNLOAD/UPLOAD Setup Using a PC Software InstallationVSI-Pro Remote Program Downloading Ver Figure P2 Remote Menu Click the Tab Remote and you will see the following MenuPC / Laptop VSI-Pro File MenuAbout Menu Communication Cable Pin OutVSI-Pro Firmware Download Utility VSI-Pro Firmware Download MenuFigure P6 Connect To Menu Figure P8 In-System Programming Display Appendix a Problem Solving GuideCharacters JITTER, JUMP, or Skew Problem Solving GuideHOW to do a Master Reset on VSI-PRO Appendix aTXD RXD GND PC-BASED Cash RegisterAppendix B Front PanelAppendix C DVROther Appendix C RS-485 NetworkDB-9 Pin-Out RJ-45 Pin-Out RS-232 Parameters RS-485 Network Data Cable WiringElectrical Characteristics Physical CharacteristicsHydra / Regcom Rear Panel Hydra / Regcom Front PanelRS-485 Networker Appendix DRS-485 Vnetworker Appendix FRS-485 Vnetworker Appendix EFigure Vnetworker Connection Diagram Vnetworker Software Figure Time / Date Set up Menu Remote Keyboard TXD RXD RTS CTS GND Vsib InstallationAppendix G Vsib DB-9M VSI-Pro DB-9MAppendix H ECR Interface CardsTcpip DB-9M AppendixTcpip 232 Adapter Tcpip 232 AdapterAppendix J Hard Alarm OutputVSI-Pro Version 13.00 Register Select Menu Appendix KAppendix K Register SelectVSI-Pro Version 13.24 Register Select Menu Appendix L Master ResetAppendix M Limited WarrantyAppendix N Limited WarrantyNorth America