AVE VSI-PRO operation manual Problem Solving Guide, Appendix a

Page 55

PROGRAMMING

5.11 HELP

“HELP” on the main-menu provides a quick reference guide of the functions of the “Up” and “Down” and “Set” buttons.

Key Definitions :

 

UP/DOWN

_ _ Change value

SET

_ _ Enter change mode

 

_ _ Save change

 

_ _ Go to position

UP AND DOWN

_ _ Save string

input

 

UP AND SET

_ _ Erase character

 

 

Figure 83: HELP Sub-Menu

PROBLEM SOLVING GUIDE

APPENDIX A

NO DATA ON-SREEN

1.Press the “Reset” button on the VSI-Pro front panel.

2.Incorrect register selected in the REGISTER SELECT menu.

3.Data cable is miswired.

4.Data cable is too long or did not use shielded cable.

5.May be connected to the wrong port.

PROBLEMS WITH CR BOARDS

1.Check that the board is seated properly in the register.

2.Check jumper settings on the CR board if applicable.

3.On CR-700, 800 and 900 series boards, make sure the 2 pin data cable is plugged in correctly.

4.On CR-220 series board, make sure the 2 pin data cable is plugged in correctly.

PROBLEMS WITH N2RS, NCR2RS, DTS2RS, B2RS ETC.

1.Check the cable to the register.

2.If VSI-Pro was working and stopped, power cycle the system. Turn off the register, unplug the power to the N2RS, and unplug the power to the VSI-Pro. Now power up the system, plug in the VSI-Pro and the N2RS. Turn on the register and do a transaction. The data should re-appear.

3.Check the cable between the VSI-Pro and the N2RS.

NO VIDEO ON MONITOR

1.VSI-Pro transformer not plugged in, or is malfunctioning.

2.Video In/Out connectors reversed, or BNC connector is not correctly wired.

3.No video input signal.

4.Bad video cable or connector.

5.Camera Iris is closed.

6.Other video device in system is off or malfunctioning.

VSI-Pro VIDEO SERIAL INTERFACE

55

Image 55
Contents June VSI-PROVSI-Pro Contents Contents Gasboy Sub-Menu Download/Upload Sub-Menu VSI / VSI+ / VSI-Pro Backward Compatibility IntroductionFeatures Features & SpecificationsSpecifications Features & SpecificationsVSI-Pro Rear Panel ConnectionsDSR PIN # Signal Name RS232PIN # Function Direction DTRVSI-Pro Connections VSI-PROFront Panel Controls User Front Panel ControlsChanging the Horizontal Position Register Select ProgrammingGetting Started Main Programming MenuTCP/IP Limitations Next page ExitDisplay SET Address ANY ExitSET Address Display Receipt ExitDevice ModelDisplay Journal Exit Device CON Sole Device Address ExitDevice Printer Device Address ANY Modetap Exit Operator Customer Combined ExitJournal Receipt Check Credit Exit Local VSS Micros IDN Network Micros ISN Network ExitNCR Jrnl Printer NCR Rcpt Printer NCR Slip Printer Title Display on Console ID ANY Working Mode ExitModel Working Mode Exit Woking ModeNext page Exit Model TK-T500 Mode Emulating ExitDevice Address Exit Device Address ANY Address ExitChoices RECEIPT, CDU 2L , C.D.U SET Term noChoices ALL, 1, 2, 3,..., 253, 254 Journal Printer Receipt PrinterText Grayscale Screen SetupBackground Grayscale Clock Sub-Menu Screen Blank Display Lines Display Format Text DisplayTitler OFF Exit TitleChoices NONE, 6, 12, 20, 30, 60, 120, 180 Screen BlankLeft Justification Line CompressChoices RS-232, Passive TAP, RS-485 CommunicationInterface Type RS-232Exception Report Overview Exception ReportsChoices NONE, ODD, Even Choices 7 orON-SCREEN Flags Hard Alarm OutputPrinter or DVR Output Total Exceptions Exception History SET Exception Output Time Stamp ExitException History Total ExceptionChoices 1 through Time Search Time Search SettingDMS-3001 DVR-3011.3021 Dest ID SCR ID ExitExample Operator None Exit 0000.00Exception no Scroll Matching Exception Strings ON/OFF History Buffer ON/OFFNegative Exception Programming NotePage Greater than OUT RangeLess than Triggered Text Exit Alarm OutputsAlarm no Exception Report Menu OutputNormal State RTSChoices no Normally open, NC Normal closed Display Text Choices 6, 12, 30, 60, 120, 180Triggered Text Display Text OFF Output Text SET Triggered ExitPort 1 Test Data Capture Register Demo Version ID Exit TEST/DEMO ModeSET Triggered Text Display Text OFF Output Text SET Triggered Text ExitReceive RX Test Port 1 TestRX /TX Test Display RX / TX Test2400 Capture to Port Capture to Memory Dump Memory ExitCapture to Port RX Baudrate Auto TX BaudrateDOWNLOAD/UPLOAD Data Cable DOWNLOAD/UPLOAD SetupDemo Demo on Power UP OFF Exit VSI-PRO Version 13.00R19 03/25/2008DOWNLOAD/UPLOAD Setup Using VSI-Pro to VSI-Pro DOWNLOAD/UPLOAD Setup Using VSI-PRO to VSI-PRODownload Setup Upload Setup Exit Download Setup Upload Setup Update Firmware ExitSoftware Installation DOWNLOAD/UPLOAD Setup Using a PCVSI-Pro Remote Program Downloading Ver Figure P2 Remote Menu Click the Tab Remote and you will see the following MenuPC / Laptop VSI-Pro File MenuAbout Menu Communication Cable Pin OutVSI-Pro Firmware Download Utility VSI-Pro Firmware Download MenuFigure P6 Connect To Menu Figure P8 In-System Programming Display Appendix a Problem Solving GuideCharacters JITTER, JUMP, or Skew Problem Solving GuideHOW to do a Master Reset on VSI-PRO Appendix aTXD RXD GND PC-BASED Cash RegisterAppendix B Front PanelDVR Appendix COther RS-485 Network Appendix CDB-9 Pin-Out RJ-45 Pin-Out RS-232 Parameters RS-485 Network Data Cable WiringElectrical Characteristics Physical CharacteristicsHydra / Regcom Rear Panel Hydra / Regcom Front PanelRS-485 Networker Appendix DRS-485 Vnetworker Appendix FRS-485 Vnetworker Appendix EFigure Vnetworker Connection Diagram Vnetworker Software Figure Time / Date Set up Menu Remote Keyboard TXD RXD RTS CTS GND Vsib InstallationAppendix G Vsib DB-9M VSI-Pro DB-9MAppendix H ECR Interface CardsTcpip DB-9M AppendixTcpip 232 Adapter Tcpip 232 AdapterAppendix J Hard Alarm OutputVSI-Pro Version 13.00 Register Select Menu Appendix KAppendix K Register SelectVSI-Pro Version 13.24 Register Select Menu Appendix L Master ResetAppendix M Limited WarrantyAppendix N Limited WarrantyNorth America