AVE VSI-PRO operation manual Clock Sub-Menu

Page 24

PROGRAMMING

T/D DISPLAY

ON

TIME FORMAT

12 HOUR

DATE FORMAT

MM/DD/YY

DAYLIGHT SAVING

DISABLED

SET TIME / DATE

 

RESET TIME / DATE

 

T/D LOCKING

ON

EXIT

 

Figure 54: CLOCK Sub-Menu

T/D DISPLAY turns the time/date display on or off. Press the “Up” or “Down” button to move the cursor to “T/D DISPLAY” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to toggle between “ON” or “OFF” and press “Set” when the desired value is displayed.

TIME DISPLAY selects either 12-hour AM/PM or 24-hour Military Time format with AM/PM. Press the “Up” or “Down” button to move the cursor to “TIME DISPLAY” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to toggle between time formats and press “Set” when the desired format is displayed.

DATE FORMAT chooses one of the three available formats. Press the “Up” or “Down” button to move the cursor to “DATE FORMAT” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to toggle between date formats and press “Set” when the desired format is displayed.

DAYLIGHT SAVING selects, for example, USA, Canada, Australia or is disabled. Press the “Up” or “Down” button to move the cursor to “DAYLIGHT SAVING” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is displayed.

SET TIME/DATE sets the clock manually. Press the “Up” or “Down” button to move the cursor to “SET TIME/ DATE” and press “Set”. The time/date will appear and the cursor will start flashing. Press the “Up” and “Down” button to change the value and press “Set” when the desired value is displayed. The value is selected and the cursor will advance to the next position. When the desired time/date is displayed, press the “Up” and “Down” buttons simultaneously to enter the time/date into memory and return to the previous menu.

RESET TIME/DATE resets the clock to the default value. Press the “Up” or “Down” button to move the cursor to “RESET TIME/DATE” and press “Set” to reset the time/date.

T/D LOCKING turns the time/date locking on or off. If the time/date locking is turned on, make sure that the time and date format selected is the same as the ATM time and date format. Press the “Up” or “Down” button to move the cursor to “T/D LOCKING” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to toggle between “ON” or “OFF” and press “Set” when the desired value is displayed.

If the T/D LOCKING is turned on, make sure that the time format selected is the same as the register’s time/date format. If the T/D LOCKING is turned on, the VSI-Pro will monitor the incoming data string. If it finds a valid time and date in one or two consecutive lines, it will set the clock to whatever time/date it finds. A valid time has the following formats:

HH:MM, HH:MM:ss HH:MM AM, HH:mm:ss AM HH:MM PM, HH:MM:ss PM

where hh is a number between 0 and 12 ( 24 if either AM or PM not present )

A valid date has the same format as for date display and has either “/” or “-" as a separator.

ON-SCREEN TITLER

Press the “Up” or “Down” button to move the cursor to “ON-SCREEN TITLER” and press “Set”. The following menu will appear:

VSI-Pro VIDEO SERIAL INTERFACE

24

Image 24
Contents VSI-PRO JuneVSI-Pro Contents Contents Gasboy Sub-Menu Download/Upload Sub-Menu Introduction VSI / VSI+ / VSI-Pro Backward CompatibilityFeatures & Specifications FeaturesFeatures & Specifications SpecificationsConnections VSI-Pro Rear PanelPIN # Signal Name RS232 PIN # Function DirectionDTR DSRVSI-PRO VSI-Pro ConnectionsUser Front Panel Controls Front Panel ControlsChanging the Horizontal Position Programming Getting StartedMain Programming Menu Register SelectNext page Exit TCP/IP LimitationsSET Address ANY Exit SET AddressDisplay Receipt Exit DisplayModel Display Journal ExitDevice CON Sole Device Address Exit DeviceOperator Customer Combined Exit Journal Receipt Check Credit ExitLocal VSS Micros IDN Network Micros ISN Network Exit Device Printer Device Address ANY Modetap ExitTitle Display on Console ID ANY Working Mode Exit Model Working Mode ExitWoking Mode NCR Jrnl Printer NCR Rcpt Printer NCR Slip Printer Model TK-T500 Mode Emulating Exit Device Address Exit Device Address ANY Address Exit Next page ExitSET Term no Choices ALL, 1, 2, 3,..., 253, 254Journal Printer Receipt Printer Choices RECEIPT, CDU 2L , C.D.UScreen Setup Text GrayscaleBackground Grayscale Clock Sub-Menu Text Display Titler OFF ExitTitle Screen Blank Display Lines Display FormatScreen Blank Choices NONE, 6, 12, 20, 30, 60, 120, 180Line Compress Left JustificationCommunication Interface TypeRS-232 Choices RS-232, Passive TAP, RS-485Exception Reports Choices NONE, ODD, EvenChoices 7 or Exception Report OverviewHard Alarm Output ON-SCREEN FlagsPrinter or DVR Output Exception History SET Exception Output Time Stamp Exit Exception HistoryTotal Exception Total ExceptionsTime Search Time Search Setting DMS-3001 DVR-3011.3021Dest ID SCR ID Exit Choices 1 throughExample 0000.00 Operator None ExitException no History Buffer ON/OFF Scroll Matching Exception Strings ON/OFFProgramming Note Negative ExceptionPage OUT Range Greater thanLess than Alarm Outputs Alarm noException Report Menu Output Triggered Text ExitRTS Normal StateChoices no Normally open, NC Normal closed Choices 6, 12, 30, 60, 120, 180 Triggered TextDisplay Text OFF Output Text SET Triggered Exit Display TextTEST/DEMO Mode SET Triggered TextDisplay Text OFF Output Text SET Triggered Text Exit Port 1 Test Data Capture Register Demo Version ID ExitPort 1 Test Receive RX TestRX / TX Test RX /TX Test DisplayCapture to Port Capture to Memory Dump Memory Exit Capture to PortRX Baudrate Auto TX Baudrate 2400DOWNLOAD/UPLOAD Setup Demo Demo on Power UP OFF ExitVSI-PRO Version 13.00R19 03/25/2008 DOWNLOAD/UPLOAD Data CableDOWNLOAD/UPLOAD Setup Using VSI-PRO to VSI-PRO DOWNLOAD/UPLOAD Setup Using VSI-Pro to VSI-ProDownload Setup Upload Setup Update Firmware Exit Download Setup Upload Setup ExitDOWNLOAD/UPLOAD Setup Using a PC Software InstallationVSI-Pro Remote Program Downloading Ver Click the Tab Remote and you will see the following Menu Figure P2 Remote MenuFile Menu About MenuCommunication Cable Pin Out PC / Laptop VSI-ProVSI-Pro Firmware Download Menu VSI-Pro Firmware Download UtilityFigure P6 Connect To Menu Figure P8 In-System Programming Display Problem Solving Guide Appendix aProblem Solving Guide HOW to do a Master Reset on VSI-PROAppendix a Characters JITTER, JUMP, or SkewPC-BASED Cash Register Appendix BFront Panel TXD RXD GNDAppendix C DVROther Appendix C RS-485 NetworkDB-9 Pin-Out RJ-45 Pin-Out RS-485 Network Data Cable Wiring Electrical CharacteristicsPhysical Characteristics RS-232 ParametersHydra / Regcom Front Panel Hydra / Regcom Rear PanelAppendix D RS-485 NetworkerAppendix F RS-485 VnetworkerAppendix E RS-485 VnetworkerFigure Vnetworker Connection Diagram Vnetworker Software Figure Time / Date Set up Menu Remote Keyboard Vsib Installation Appendix GVsib DB-9M VSI-Pro DB-9M TXD RXD RTS CTS GNDECR Interface Cards Appendix HAppendix Tcpip 232 AdapterTcpip 232 Adapter Tcpip DB-9MHard Alarm Output Appendix JAppendix K VSI-Pro Version 13.00 Register Select MenuRegister Select Appendix KVSI-Pro Version 13.24 Register Select Menu Master Reset Appendix LLimited Warranty Appendix MLimited Warranty Appendix NNorth America