AVE VSI-PRO Capture to Port Capture to Memory Dump Memory Exit, RX Baudrate Auto TX Baudrate

Page 45

PROGRAMMING

DATA CAPTURE

This feature allow user to store the data either internal memory of VSI-Pro or some external data storing device. Press the “Up” or “Down” button to move the cursor to “DATA CAPTURE” and press “Set”. The following sub-menu will appear:

CAPTURE TO PORT 1

CAPTURE TO MEMORY

DUMP MEMORY

EXIT

Figure 75: DATA CAPTURE Sub-Menu

Press “Set” to return to the previous menu.

CAPTURE TO PORT 1

This feature redirect the incoming data to VSI-Pro to its output ( Pin 3 of AT type RS-232 female connector ) where that data can be stored to data storing devices (e.g. PC). This feature is useful to store non-RS 232 format data. Press the “Up” or “Down” button to move the cursor to “CAPTURE TO PORT 1 and press “Set”. The following display will appear (example only):

RX BAUDRATE :

AUTO

TX BAUDRATE :

2400

PARITY :

 

 

 

NONE

DATA BIT :

 

 

 

 

8

 

 

 

 

 

 

HANDSHAKING :

 

 

OFF

 

 

 

 

 

 

 

 

BAUDRATE DETECTION..

Figure 76: CAPTURE TO PORT 1 Display

Press “Set” to return to the previous menu.

CAPTURE TO MEMORY

This feature allow you to store the data in the internal memory of VSI-Pro. You can store up to 20 kilobytes of data in the internal memory of VSI-Pro. Power up the VSI-Pro for 24 hours prior to download of data. This will provide VSI- Pro’s internal battery a full charge to hold data in its memory. Press the “Up” or “Down” button to move the cursor to “CAPTURE TO MEMORY” and press “Set”. The following display will appear (example only):

RX BAUDRATE :

TX BAUDRATE :

PARITY :

DATA BIT :

HANDSHAKING :

BAUDRATE DETECTION..

AUTO 2400 NONE

8

OFF

Figure 77: CAPTURE TO MEMORY Display

Press “Set” to return to the previous menu.

NOTE ?

VSI-Pro can only hold up to 20 kilobytes of data to make sure that you only transfer the data which is in correct format.

VSI-Pro VIDEO SERIAL INTERFACE

45

Image 45
Contents June VSI-PROVSI-Pro Contents Contents Gasboy Sub-Menu Download/Upload Sub-Menu VSI / VSI+ / VSI-Pro Backward Compatibility IntroductionFeatures Features & SpecificationsSpecifications Features & SpecificationsVSI-Pro Rear Panel ConnectionsPIN # Function Direction PIN # Signal Name RS232DTR DSRVSI-Pro Connections VSI-PROFront Panel Controls User Front Panel ControlsChanging the Horizontal Position Getting Started ProgrammingMain Programming Menu Register SelectTCP/IP Limitations Next page ExitSET Address SET Address ANY ExitDisplay Receipt Exit DisplayDisplay Journal Exit ModelDevice CON Sole Device Address Exit DeviceJournal Receipt Check Credit Exit Operator Customer Combined ExitLocal VSS Micros IDN Network Micros ISN Network Exit Device Printer Device Address ANY Modetap ExitModel Working Mode Exit Title Display on Console ID ANY Working Mode ExitWoking Mode NCR Jrnl Printer NCR Rcpt Printer NCR Slip PrinterDevice Address Exit Model TK-T500 Mode Emulating ExitDevice Address ANY Address Exit Next page ExitChoices ALL, 1, 2, 3,..., 253, 254 SET Term noJournal Printer Receipt Printer Choices RECEIPT, CDU 2L , C.D.UScreen Setup Text GrayscaleBackground Grayscale Clock Sub-Menu Titler OFF Exit Text DisplayTitle Screen Blank Display Lines Display FormatChoices NONE, 6, 12, 20, 30, 60, 120, 180 Screen BlankLeft Justification Line CompressInterface Type CommunicationRS-232 Choices RS-232, Passive TAP, RS-485Choices NONE, ODD, Even Exception ReportsChoices 7 or Exception Report OverviewHard Alarm Output ON-SCREEN FlagsPrinter or DVR Output Exception History Exception History SET Exception Output Time Stamp ExitTotal Exception Total ExceptionsDMS-3001 DVR-3011.3021 Time Search Time Search SettingDest ID SCR ID Exit Choices 1 throughExample 0000.00 Operator None ExitException no Scroll Matching Exception Strings ON/OFF History Buffer ON/OFFNegative Exception Programming NotePage OUT Range Greater thanLess than Alarm no Alarm OutputsException Report Menu Output Triggered Text ExitRTS Normal StateChoices no Normally open, NC Normal closed Triggered Text Choices 6, 12, 30, 60, 120, 180Display Text OFF Output Text SET Triggered Exit Display TextSET Triggered Text TEST/DEMO ModeDisplay Text OFF Output Text SET Triggered Text Exit Port 1 Test Data Capture Register Demo Version ID ExitReceive RX Test Port 1 TestRX /TX Test Display RX / TX TestCapture to Port Capture to Port Capture to Memory Dump Memory ExitRX Baudrate Auto TX Baudrate 2400Demo Demo on Power UP OFF Exit DOWNLOAD/UPLOAD SetupVSI-PRO Version 13.00R19 03/25/2008 DOWNLOAD/UPLOAD Data CableDOWNLOAD/UPLOAD Setup Using VSI-Pro to VSI-Pro DOWNLOAD/UPLOAD Setup Using VSI-PRO to VSI-PRODownload Setup Upload Setup Exit Download Setup Upload Setup Update Firmware ExitDOWNLOAD/UPLOAD Setup Using a PC Software InstallationVSI-Pro Remote Program Downloading Ver Figure P2 Remote Menu Click the Tab Remote and you will see the following MenuAbout Menu File MenuCommunication Cable Pin Out PC / Laptop VSI-ProVSI-Pro Firmware Download Utility VSI-Pro Firmware Download MenuFigure P6 Connect To Menu Figure P8 In-System Programming Display Appendix a Problem Solving GuideHOW to do a Master Reset on VSI-PRO Problem Solving GuideAppendix a Characters JITTER, JUMP, or SkewAppendix B PC-BASED Cash RegisterFront Panel TXD RXD GNDAppendix C DVROther Appendix C RS-485 NetworkDB-9 Pin-Out RJ-45 Pin-Out Electrical Characteristics RS-485 Network Data Cable WiringPhysical Characteristics RS-232 ParametersHydra / Regcom Rear Panel Hydra / Regcom Front PanelRS-485 Networker Appendix DRS-485 Vnetworker Appendix FAppendix E RS-485 VnetworkerFigure Vnetworker Connection Diagram Vnetworker Software Figure Time / Date Set up Menu Remote Keyboard Appendix G Vsib InstallationVsib DB-9M VSI-Pro DB-9M TXD RXD RTS CTS GNDAppendix H ECR Interface CardsTcpip 232 Adapter AppendixTcpip 232 Adapter Tcpip DB-9MAppendix J Hard Alarm OutputVSI-Pro Version 13.00 Register Select Menu Appendix KAppendix K Register SelectVSI-Pro Version 13.24 Register Select Menu Appendix L Master ResetAppendix M Limited WarrantyAppendix N Limited WarrantyNorth America