DISK/TAPE CONTROLLER DATA
B
Disk/Tape Controller Modules Supported
The following VMEbus disk/tape controller modules are supported by the 197Bug. The default address for each type of controller is the First Address and the controller can be addressed by the First CLUN during commands BH, BO, or IOP, or during TRAP #496 calls .DSKRD or .DSKWR. Note that if another one of the same type of controller is used, the second one must have its address changed by its onboard jumpers and/or switches, so that it matches the Second Address and can be called up by the Second CLUN.
Controller Type | First | First | Second | Second | |
CLUN | Address | CLUN | Address | ||
| |||||
|
|
|
|
| |
|
|
|
|
| |
MVME197LE - Single Board Computer | $00 | ||||
|
|
|
|
| |
MVME320 - Winchester/Floppy | $11 | $FFFFB000 | $12 | $FFFFAC00 | |
Controller |
|
|
|
| |
|
|
|
|
| |
MVME323 - ESDI Winchester | $08 | $FFFFA000 | $09 | $FFFFA200 | |
Controller |
|
|
|
| |
|
|
|
|
| |
MVME327A - SCSI Controller | $02 | $FFFFA600 | $03 | $FFFFA700 | |
|
|
|
|
| |
MVME328 - SCSI Controller | $06 | $FFFF9000 | $07 | $FFFF9800 | |
|
|
|
|
| |
MVME350 - Streaming Tape Controller | $04 | $FFFF5000 | $05 | $FFFF5100 | |
|
|
|
|
|