Installation
Connecting a DC Power Supply
Warning
Warning
Warning
Warning
Warning
Warning
A readily accessible
Use copper conductors only. Statement 1025
This product requires
When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Hazardous voltage or energy may be present on DC power terminals. Always replace cover when terminals are not in service. Be sure uninsulated conductors are not accessible when cover is in place. Statement 1075
Procedure
Step 1 Install the DC power supply in the chassis, making note of the bay number, so you are sure to connect the wiring to the appropriate terminals on the DC PDU at the chassis rear.
Step 2 Verify that power is off to the DC circuit or circuits on the power supply that you are installing. Step 3 Ensure that all site power and grounding requirements have been met.
Step 4 Remove the plastic cover from the DC terminals by squeezing the flanges at the top and bottom of the cover.
Step 5 Connect the ground wires to the power supply terminal block, shown as a green wire below. Only one ground connection is required, though there may be up to four DC connections.
Step 6 Connect the
Cisco UCS 5108 Server Chassis Installation Guide