Technical Specifications
Specifications for the Cisco UCS 5108 Blade Server Chassis Power Supply Units
Specifications for the Cisco UCS 5108 Blade Server Chassis Power Supply Units
Table 12: |
|
| ||
Description | Specification |
|
| |
Minimum Software requirement | UCS Software Release 1.0(1) | |||
200 to 240 VAC nominal (Range: 180 to 264 VAC) | ||||
50 to 60 Hz nominal (Range: 47 to 63 Hz) | ||||
15.5 A @ 200 VAC |
| |||
Maximum Input VA | 2790 VA @ 200 VAC |
| ||
Maximum output power per power supply | 2500 W @ 200 to 240 VAC (up to four power supplies) | |||
Maximum inrush current | 35 A < sub cycle duration |
| ||
Maximum Heat Output | 8525 BTU |
|
|
|
Maximum hold up time | 12 ms |
|
|
|
Power supply output voltage | 12 VDC |
|
|
|
Efficiency Rating | Climate Savers Gold |
| ||
Efficiency (80Plus Gold Certified) | 10% | 20% | 50% | 100% |
| 88.61% 91.64% | 92.21% | 90.97% | |
Input connector | IEC320 C20 |
|
| |
Table 13: |
| |||
Description | Specification |
|
| |
Minimum Software requirement | UCS Software Release 2.0(2) | |||
200 to 240 VAC nominal (Range: 180 to 264 VAC) | ||||
50 and 60 Hz nominal (Range: 47 to 63 Hz) | ||||
< 16 Amps @ 200 VAC |
|
Cisco UCS 5108 Server Chassis Installation Guide
72 |
|