Dell M905 manual Blade Features

Page 8

Blade Features

Performance Features

PowerEdge M905

Four AMDOpteron8000 Series dual-core or quad-core processors.

A minimum of 8 GB of 677 MHz DDR2 memory modules, upgradable to a maximum of 192 GB by installing pairs of 1-GB, 2-GB, 4-GB, or 8-GB modules in the 24 memory module sockets on the blade system board. The blade also supports memory sparing if eight or sixteen memory module sockets are populated with identical memory modules.

An SD (Secure Digital) card slot for embedded Hyperviser support.

PowerEdge M805

Two AMD Opteron 2000 Series dual-core or quad-core processors.

A minimum of 4 GB of 677 MHz DDR2 memory modules, upgradable to a maximum of 128 GB by installing pairs of 1-GB, 2-GB, 4-GB, or 8-GB modules in the 16 memory module sockets on the blade system board. The blade also supports memory sparing if eight or sixteen memory module sockets are populated with identical memory modules.

An SD card slot for embedded Hyperviser support.

PowerEdge M600

One or two Intel® Xeon® dual-core or quad-core processors

A minimum of 1 GB of 677-MHz FBD memory modules, upgradable to a maximum of 64 GB by installing pairs of 512-MB, 1-GB, 2-GB, 4-GB, or 8-GB modules in the eight memory module sockets on the blade system board. The blade also supports memory sparing or memory mirroring if all eight memory module sockets are populated with identical memory modules.

6

Getting Started With Your System

Image 8
Contents Getting Started With Your System Page Getting Started With Your System May W001C System Features System Enclosure FeaturesPage Getting Started With Your System Blade Features PowerEdge M605 Supported Operating Systems Other Information You May Need Unpack the System Install the System in a Rack Install the BladesConnect the System to Power Connect the CMC and KVM ModulesTurn on the System Complete the 0perating System Setup Turn on the BladesTechnical Specifications Blade SpecificationsUSB System Enclosure Specifications Inrush current may reach 55 a per Module Specifications Above 900 m 2955 ft Environmental Maximum shock Operating Getting Started With Your System Guide de mise en route Remarques, avis et précautions Caractéristiques du système Caractéristiques du châssisSécurité des accès utilisateur Guide de mise en route Caractéristiques des lames PowerEdge M600 Guide de mise en route Systèmes dexploitation pris en charge Autres informations utiles Installation du système dans un rack Déballage du systèmeInstallation des lames Connexion du contrôleur CMC et des modules KVM Branchement du système sur le secteurMise sous tension du système Finalisation de linstallation du système dexploitation Mise sous tension des lamesSpécifications techniques Spécifications des lamesChaud de 2,5 pouces 5709S à double port Spécifications du châssis Souris Spécifications des modules dE/S Pieds Primeiros passos com o sistema Notas, avisos e advertências Recursos do sistema Recursos da caixa do sistemaPrimeiros passos com o sistema Page Recursos da lâmina Recursos comuns Primeiros passos com o sistema Sistemas operacionais admitidos Outras informações úteisComo obter assistência técnica Instalação do sistema no rack Instalação e configuraçãoRemoção do sistema da embalagem Instale as lâminas Conecte os módulos CMC e KVMConecte o sistema à energia Ligue o sistema Ligue as lâminasEspecificações da lâmina Conclua a configuração do sistema operacionalEspecificações técnicas Memória continuação Conectores Externos Especificações da caixa do sistema Com USB 2.0 para teclado e mouse Especificações do módulo de E/S De 31 G por até 2,6 ms Primeiros passos com o sistema Procedimientos iniciales con el sistema Notas, avisos y precauciones Características del sistema Características del alojamiento del sistemaCaracterísticas de administración de sistemas Page Características del módulo de alta densidad Uno o dos procesadores Intel Xeon de dos o cuatro núcleos Procedimientos iniciales con el sistema Sistemas operativos admitidos Otra información útil Desembalaje del sistema Instalación y configuraciónObtención de asistencia técnica Instalación del sistema en un rack Instalación de los módulos de alta densidadConexión de los módulos CMC y KVM Conexión del sistema a la alimentación Encendido del sistemaEncendido de los módulos de alta densidad Especificaciones del módulo de alta densidad Finalización de la configuración del sistema operativoEspecificaciones técnicas De 2,5 pulgadas 5709S integradas de dos puertos Especificaciones del alojamiento del sistema Con USB 2.0 para el teclado y el ratón Especificaciones del módulo de E/S Módulos opcionalesPor cada 300 m