Page 20

ping ipaddress

Where ipaddress is the desired IP address of the Serial Device Server and macaddress is the MAC address of the Serial Device Server (found on the label affixed to the Serial Device Server). For example:

arp –s 192.168.5.53 00:40:17:00:00:01 ping 192.168.5.53

Note that Windows systems use the format xx-xx-xx-xx-xx-xx for the MAC address (for example, 00-0017-00-00-01).

You will see a reply from the Serial Device Server with the number of bytes and other information if the address was successfully set.

If you get an error message or no response, then the IP address was not set. If this is the case, the Serial Device Server may not be at its default configuration. To reset the Serial Device Server to its default settings, hold down the reset pushbutton for more than five seconds.

d.You are now ready to configure the Serial Device Server (skip the remainder of this section).

NOTE: Skip the following step if you have configured IP address of the Serial Device Server using an Ethernet cable.

3.If you are using a wireless connection for the first-time configuration of the Serial Device Server, you must set up a temporary ad hoc wireless connection as described in the following steps. Please note that because this is a fairly complex process, we do not recommend it unless it is not possible to use a wired connection.

a.Disconnect your PC and the Serial Device Server from your network, and temporarily set the PC settings as follows:

IP address: 192.0.0.191

Wireless Mode: Ad Hoc (sometimes referred to as Peer-to-Peer)

Channel: 11

SSID (or wireless network name): serserv

b.Power on the PC and the Serial Device Server. You can connect to the Serial Device Server by specifying its default IP address of 192.0.0.192 using a web browser as described in the next section. When you have connected to the Serial Device Server, you must then change the IP address and enter the required wireless networking parameters using either the web browser interface or the internal command console (see next two sections) for operation on your wireless network.

c.After you complete the entire Serial Device Server configuration process, you must set your PC back to its original network settings.

Page 14

Silex

Configuring the Serial Device Server

 

Part Number 140-00188-210A

 

Image 20
Contents SX-500-1402 Serial Device Server Trademarks Page Contents Figures Contents Silex Part Number 140-00188-210A Emissions Disclaimer Safety PrecautionsAbout This Reference Guide Revision History 2009.08.13 Lee Aydelotte Initial ReleaseIntroduction SX-500Logical Ports Port Name DescriptionLED FIPS-140-2 Interface Physical Logical InterfaceWPA2 AES-CCMP ConfigurationRequired Setting Https Physical Protection Secure OperationInstalling the Serial Device Server Installing the Serial Device Server HardwareVerify Package Contents RS-232 connector pinouts and cabling Monitoring Serial Device Server Status Status Monitors Function StateChapter Configuring the Serial Device Server Basic Configuration RequirementsTCP/IP Settings Wireless Configuration SettingsConfiguration Methods First-Time IP Address Configuration Ping ipaddress Using a Web Browser to Configure the Serial Device Server Silex Authentication Server Certificate You can skip the remainder of this chapter AD-HOC Disabled Init ExitChapter Using the Serial Device Server with Your Application Serial Port EmulatorRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportPrint Server Mode Console Mode SwitchingAT Commands SET Port S1 Filter ATChapter Advanced Configuration Factory Default SettingsFactory Default Settings Parameter Description CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingDNS Using AT Modem CommandsTCP/IP Settings Parameter Standard AT Commands Supported AT Commands Parameter DescriptionAT#Cset nw ssid silex#Csave Parameter Command DescriptionExtended AT Commands Parameter Description Response Codes Response Codes Numeric Code DescriptionChapter Troubleshooting Email Tech support support@silexamerica.com Radio Performance Specifications Parameter Chapter Product SpecificationsProduct Specifications Component Parameter Specifications TCP Port ConnectionsTCP Port Connections Port Destination DeviceAppendix a Advanced Security Configuration PSKEAP Ttls LeapEncryption Mode Wireless Security Only Key Selection Wireless Security OnlyWEP Key Value Wireless Security Only Pre-Shared Key Wireless Security OnlyWireless Authentication Type Wireless Security Only Wired Authentication Type Wired Ethernet Networks OnlyAuthentication Attempts PasswordProduct Specifications Silex Part Number 140-00188-210A Appendix B Console Commands Wireless and Network Security CommandsNetwork Commands Description Signal Quality Signal Strength = Noise LevelSET NW Ethauth Ttls TLS Peap Command DescriptionTLS PSK SET NW KEY# Wifi RTS Threshold = CL NW BSsidSET NW RTS SET NW CertcnSET NW CERTCN2 SET NW CertexpSET NW Certkey SET NW IDSET NW Realm SET NW Wpagroup Enable DisableSET NW Inap PAPMSCHAPV2 Port Commands SET NW ResetPort Commands Description XON/XOFFServer Information Commands Server Information Commands DescriptionCL Port S1 JOB SET Port S1 Size 7SET SERVEr NAme Name SET Snmp CONtact StringSET Snmp LOCation string SH SerialService Commands Service Commands DescriptionTwcffffff BINARYP1TEXTP1 TWCFFFFFFP14String Commands String CommandsTCP/IP Commands TCP/IP Commands DescriptionEnter LANGUAGE= POSTSCRIPT\0AAll hosts permitted access SET ARP ENable DIsableSET IP BAnner ENable DIsable SET IP Chksum ENable DIsableAuto Bootp Rarp Dhcp Static SET IP FTPSET IP Http SET IP LPDSET IP TCP SET IP TftpXxxxxxS1A 9100 XxxxxxS1B 3001 SH IPAuto Firmware Update Firmware Update Command DescriptionMiscellaneous Commands Description Miscellaneous CommandsHelp Commands Console Commands Silex Part Number 140-00188-210A Appendix C Firmware Update Procedures Firmware Update Procedures Silex Part Number 140-00188-210A Appendix D Safety and Regulatory Notices Information for United States UsersInformation for Canadian Users IC notice SX-500  FCC ID N6C-SX10WGInformation for European Users SX-500 Declaration of Conformity CE SX-500Appendix E Silex Contact Information Silex Technology America, IncSilex Technology Europe GmbH Silex Technology Beijing, IncSilex Technology America, Inc

SX-500-1402 specifications

The Silex Technology SX-500-1402 is an advanced industrial wireless module designed for seamless integration into various applications requiring high-performance wireless connectivity. This module is particularly renowned for its robust features, making it ideal for use in automation, healthcare, and smart city applications.

One of the main features of the SX-500-1402 is its dual-band Wi-Fi capability, which operates on both 2.4 GHz and 5 GHz frequencies. This not only provides flexibility for different environments but also enhances the overall performance by reducing interference and optimizing data throughput. The module supports Wi-Fi 5 (802.11ac), enabling high-speed data transmission and ensuring reliable connectivity even in crowded environments.

Another key aspect of the SX-500-1402 is its compact size and lightweight design, offering an excellent solution for space-constrained applications. The module features a PCB form factor that facilitates easy integration into diverse devices while minimizing additional footprint.

The SX-500-1402 boasts advanced security features, including WPA3 support, ensuring encryption and secure data transmission across networks. This is a critical requirement for applications in healthcare and finance, where safeguarding sensitive information is paramount. Furthermore, the module supports secure boot and firmware updates, further enhancing its security posture.

In terms of power management, the Silex module is designed for energy efficiency, making it suitable for battery-powered applications. It features various power-saving modes that help to extend battery life without compromising performance, enabling devices to operate for longer periods without frequent recharging.

The SX-500-1402 also integrates seamlessly with diverse host interfaces, such as UART, SPI, and I2C, facilitating easy connectivity to microcontrollers and other devices. This versatility makes it an ideal choice for developers looking to prototype and bring their IoT solutions to market swiftly.

Key specifications of the SX-500-1402 include a maximum data rate of 867 Mbps in the 5 GHz band, operating temperature range from -20 to 70 degrees Celsius, and an extended range due to its MIMO (Multiple Input, Multiple Output) technology, which further enhances performance in environments with obstacles.

In summary, the Silex Technology SX-500-1402 is an exceptional choice for applications requiring reliable, high-speed wireless communication. With its advanced features, robust security measures, and versatile integration options, it stands out as a premier solution in the industrial wireless module landscape.