Silex technology SX-500-1402 manual Silex

Page 22

If you used DHCP, verify that the IP address is correctly set. If you used the default 192.0.0.192 IP address, you MUST change it to a new valid IP address. If necessary, change the Subnet Mask and Gateway. It is generally not necessary to change the other parameters on this page (refer to Chapter 5 for advanced configuration information.

Note that on-line help information is available on every configuration page.

Click the Submit button at the bottom of the window (you may need to scroll) to save your changes.

NOTE: If you are using DHCP on your network, the SX- 500 should have acquired valid IP settings at this point and no further configuration is necessary. However, for some installations, a static IP address is preferred. If your DHCP server does not allow the SX-500 to keep its assigned IP address permanently, then you must manually assign an IP address. In this case, use a static IP address outside the range reserved for DHCP (see your DHCP server documentation for details). To assign a static IP address, select Set Permanent as the IP Address Resolution, and assign a valid static IP address for your network. Click on OK to save the new settings.

4. Click Wireless on the left side of the screen to configure the 802.11a/b/g wireless settings (for WLAN models only; skip to the next section if you have an Ethernet model). To operate on an 802.11a/b/g network, the Serial Device Server configuration must be configured with the wireless configuration and security parameters required to allow the Serial Device Server to communicate over your wireless network (check with your network administrator if you do not know these parameters).

Select either Infrastructure (if you are using an access point) or Ad Hoc (point-to-point) as the wireless mode

Enter the SSID for your network

If you are using Ad Hoc, select the RF channel (not required for infrastructure)

The other parameters on this page do not normally need to be changed (refer to Chapter 5 for information on advanced configuration).

Click the Submit button at the bottom of the window (you may need to scroll) to save your changes.

Now click Configure Network Security to configure the wireless security parameters.

Page 16

Silex

Configuring the Serial Device Server

 

Part Number 140-00188-210A

 

Image 22
Contents SX-500-1402 Serial Device Server Trademarks Page Contents Figures Contents Silex Part Number 140-00188-210A About This Reference Guide Safety PrecautionsEmissions Disclaimer Revision History 2009.08.13 Lee Aydelotte Initial ReleaseIntroduction SX-500LED Logical PortsPort Name Description FIPS-140-2 Interface Physical Logical InterfaceRequired Setting ConfigurationWPA2 AES-CCMP Https Physical Protection Secure OperationVerify Package Contents Installing the Serial Device Server HardwareInstalling the Serial Device Server RS-232 connector pinouts and cabling Monitoring Serial Device Server Status Status Monitors Function StateTCP/IP Settings Chapter Configuring the Serial Device ServerBasic Configuration Requirements Wireless Configuration SettingsConfiguration Methods First-Time IP Address Configuration Ping ipaddress Using a Web Browser to Configure the Serial Device Server Silex Authentication Server Certificate You can skip the remainder of this chapter AD-HOC Disabled Init ExitChapter Using the Serial Device Server with Your Application Serial Port EmulatorRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportPrint Server Mode Console Mode SwitchingAT Commands SET Port S1 Filter ATFactory Default Settings Parameter Description Chapter Advanced ConfigurationFactory Default Settings CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingTCP/IP Settings Parameter Using AT Modem CommandsDNS Standard AT Commands Supported AT Commands Parameter DescriptionExtended AT Commands Parameter Description Parameter Command DescriptionAT#Cset nw ssid silex#Csave Response Codes Response Codes Numeric Code DescriptionChapter Troubleshooting Email Tech support support@silexamerica.com Product Specifications Component Chapter Product SpecificationsRadio Performance Specifications Parameter TCP Port Connections Parameter SpecificationsTCP Port Connections Port Destination DeviceEAP Appendix a Advanced Security ConfigurationPSK Ttls LeapWEP Key Value Wireless Security Only Encryption Mode Wireless Security OnlyKey Selection Wireless Security Only Pre-Shared Key Wireless Security OnlyAuthentication Attempts Wireless Authentication Type Wireless Security OnlyWired Authentication Type Wired Ethernet Networks Only PasswordProduct Specifications Silex Part Number 140-00188-210A Network Commands Description Appendix B Console CommandsWireless and Network Security Commands Signal Quality Signal Strength = Noise LevelTLS PSK Command DescriptionSET NW Ethauth Ttls TLS Peap SET NW KEY# SET NW RTS Wifi RTS Threshold =CL NW BSsid SET NW CertcnSET NW Certkey SET NW CERTCN2SET NW Certexp SET NW IDSET NW Inap PAPMSCHAPV2 SET NW Wpagroup Enable DisableSET NW Realm Port Commands Description Port CommandsSET NW Reset XON/XOFFCL Port S1 JOB Server Information CommandsServer Information Commands Description SET Port S1 Size 7SET Snmp LOCation string SET SERVEr NAme NameSET Snmp CONtact String SH SerialService Commands Service Commands DescriptionTEXTP1 TwcffffffBINARYP1 TWCFFFFFFP14String Commands String CommandsEnter LANGUAGE= TCP/IP CommandsTCP/IP Commands Description POSTSCRIPT\0ASET IP BAnner ENable DIsable All hosts permitted accessSET ARP ENable DIsable SET IP Chksum ENable DIsableSET IP Http Auto Bootp Rarp Dhcp StaticSET IP FTP SET IP LPDSET IP TCP SET IP TftpAuto SH IPXxxxxxS1A 9100 XxxxxxS1B 3001 Firmware Update Firmware Update Command DescriptionHelp Commands Miscellaneous CommandsMiscellaneous Commands Description Console Commands Silex Part Number 140-00188-210A Appendix C Firmware Update Procedures Firmware Update Procedures Silex Part Number 140-00188-210A Appendix D Safety and Regulatory Notices Information for United States UsersInformation for Canadian Users IC notice SX-500  FCC ID N6C-SX10WGInformation for European Users SX-500 Declaration of Conformity CE SX-500Silex Technology Europe GmbH Appendix E Silex Contact InformationSilex Technology America, Inc Silex Technology Beijing, IncSilex Technology America, Inc

SX-500-1402 specifications

The Silex Technology SX-500-1402 is an advanced industrial wireless module designed for seamless integration into various applications requiring high-performance wireless connectivity. This module is particularly renowned for its robust features, making it ideal for use in automation, healthcare, and smart city applications.

One of the main features of the SX-500-1402 is its dual-band Wi-Fi capability, which operates on both 2.4 GHz and 5 GHz frequencies. This not only provides flexibility for different environments but also enhances the overall performance by reducing interference and optimizing data throughput. The module supports Wi-Fi 5 (802.11ac), enabling high-speed data transmission and ensuring reliable connectivity even in crowded environments.

Another key aspect of the SX-500-1402 is its compact size and lightweight design, offering an excellent solution for space-constrained applications. The module features a PCB form factor that facilitates easy integration into diverse devices while minimizing additional footprint.

The SX-500-1402 boasts advanced security features, including WPA3 support, ensuring encryption and secure data transmission across networks. This is a critical requirement for applications in healthcare and finance, where safeguarding sensitive information is paramount. Furthermore, the module supports secure boot and firmware updates, further enhancing its security posture.

In terms of power management, the Silex module is designed for energy efficiency, making it suitable for battery-powered applications. It features various power-saving modes that help to extend battery life without compromising performance, enabling devices to operate for longer periods without frequent recharging.

The SX-500-1402 also integrates seamlessly with diverse host interfaces, such as UART, SPI, and I2C, facilitating easy connectivity to microcontrollers and other devices. This versatility makes it an ideal choice for developers looking to prototype and bring their IoT solutions to market swiftly.

Key specifications of the SX-500-1402 include a maximum data rate of 867 Mbps in the 5 GHz band, operating temperature range from -20 to 70 degrees Celsius, and an extended range due to its MIMO (Multiple Input, Multiple Output) technology, which further enhances performance in environments with obstacles.

In summary, the Silex Technology SX-500-1402 is an exceptional choice for applications requiring reliable, high-speed wireless communication. With its advanced features, robust security measures, and versatile integration options, it stands out as a premier solution in the industrial wireless module landscape.