Silex technology SX-500-1402 manual Raw TCP connection, Telnet ipaddress portnumber

Page 28

After the Serial Port Emulator software has started, you will see a list of all the configured Serial Device Servers on the network. Right click on the name of the Serial Device Server that you want the virtual COM port to connect to (the default name is SLXxxxxxx, where xxxxxx is the last six digits of the Serial Device Server MAC address), and then click Virtual Port. You will be asked to select the name of the virtual COM port (for example, COM3).

Click OK after you have selected the name, and you now ready to use the virtual COM port.

Using virtual COM port is identical to using a normal COM port. For example, if you configure a virtual COM port called COM3, this port will show up as one of the available serial ports when you use the Windows HyperTerminal Accessory program.

Raw TCP connection

You can communicate directly from your application program to the Serial Device Server using a raw TCP connection. This is done by opening a TCP port on the Serial Device Server and then sending and receiving data to this port via a socket or equivalent API. This method is more efficient than using the Serial Port Emulator, and does not require any additional software to be installed on your computer.

If you are using a raw TCP connection, the default TCP port number (you can use any or all of these port numbers) for normal connections. If you want to be able to access your device’s modem control signals from your computer system, then the TCP port number is 9200 (this enables RFC 2217 support). You can change the port number, if desired, by modifying one of the Serial Device Server services. To change the TCP port number:

1.Connect to the Serial Device Server with a web browser (see chapter 3 for instructions on doing this);

2.After you have logged in, click I/O Services on the left side of the page.

3.Click on the service name that you want to change (any one of the services is OK, provided that you are not using the existing TCP port number of that service for a different application).

4.Change the Raw TCP Port to the desired number (must be greater than 1023).

5.Click Submit to save your change.

You can test this connection by using the TELNET utility from the Windows Command Prompt (MS-DOS prompt), Mac OS X Terminal Utility, or UNIX/Linux command line as follows:

telnet ipaddress portnumber

Page 22

Silex

Configuring the Serial Device Server

 

Part Number 140-00188-210A

 

Image 28
Contents SX-500-1402 Serial Device Server Trademarks Page Contents Figures Contents Silex Part Number 140-00188-210A About This Reference Guide Safety PrecautionsEmissions Disclaimer Revision History 2009.08.13 Lee Aydelotte Initial ReleaseIntroduction SX-500Logical Ports Port Name DescriptionLED FIPS-140-2 Interface Physical Logical InterfaceRequired Setting ConfigurationWPA2 AES-CCMP Https Physical Protection Secure OperationVerify Package Contents Installing the Serial Device Server HardwareInstalling the Serial Device Server RS-232 connector pinouts and cabling Monitoring Serial Device Server Status Status Monitors Function StateChapter Configuring the Serial Device Server Basic Configuration RequirementsTCP/IP Settings Wireless Configuration SettingsConfiguration Methods First-Time IP Address Configuration Ping ipaddress Using a Web Browser to Configure the Serial Device Server Silex Authentication Server Certificate You can skip the remainder of this chapter AD-HOC Disabled Init ExitChapter Using the Serial Device Server with Your Application Serial Port EmulatorRaw TCP connection Telnet ipaddress portnumberECable Mode RFC 2217 Remote Modem Control SupportPrint Server Mode Console Mode SwitchingAT Commands SET Port S1 Filter ATChapter Advanced Configuration Factory Default SettingsFactory Default Settings Parameter Description CTS/RTSModifying TCP/IP Settings Parameter Description Settings Default SettingTCP/IP Settings Parameter Using AT Modem CommandsDNS Standard AT Commands Supported AT Commands Parameter DescriptionExtended AT Commands Parameter Description Parameter Command DescriptionAT#Cset nw ssid silex#Csave Response Codes Response Codes Numeric Code DescriptionChapter Troubleshooting Email Tech support support@silexamerica.com Product Specifications Component Chapter Product SpecificationsRadio Performance Specifications Parameter Parameter Specifications TCP Port ConnectionsTCP Port Connections Port Destination DeviceAppendix a Advanced Security Configuration PSKEAP Ttls LeapEncryption Mode Wireless Security Only Key Selection Wireless Security OnlyWEP Key Value Wireless Security Only Pre-Shared Key Wireless Security OnlyWireless Authentication Type Wireless Security Only Wired Authentication Type Wired Ethernet Networks OnlyAuthentication Attempts PasswordProduct Specifications Silex Part Number 140-00188-210A Appendix B Console Commands Wireless and Network Security CommandsNetwork Commands Description Signal Quality Signal Strength = Noise LevelTLS PSK Command DescriptionSET NW Ethauth Ttls TLS Peap SET NW KEY# Wifi RTS Threshold = CL NW BSsidSET NW RTS SET NW CertcnSET NW CERTCN2 SET NW CertexpSET NW Certkey SET NW IDSET NW Inap PAPMSCHAPV2 SET NW Wpagroup Enable DisableSET NW Realm Port Commands SET NW ResetPort Commands Description XON/XOFFServer Information Commands Server Information Commands DescriptionCL Port S1 JOB SET Port S1 Size 7SET SERVEr NAme Name SET Snmp CONtact StringSET Snmp LOCation string SH SerialService Commands Service Commands DescriptionTwcffffff BINARYP1TEXTP1 TWCFFFFFFP14String Commands String CommandsTCP/IP Commands TCP/IP Commands DescriptionEnter LANGUAGE= POSTSCRIPT\0AAll hosts permitted access SET ARP ENable DIsableSET IP BAnner ENable DIsable SET IP Chksum ENable DIsableAuto Bootp Rarp Dhcp Static SET IP FTPSET IP Http SET IP LPDSET IP TCP SET IP TftpAuto SH IPXxxxxxS1A 9100 XxxxxxS1B 3001 Firmware Update Firmware Update Command DescriptionHelp Commands Miscellaneous CommandsMiscellaneous Commands Description Console Commands Silex Part Number 140-00188-210A Appendix C Firmware Update Procedures Firmware Update Procedures Silex Part Number 140-00188-210A Appendix D Safety and Regulatory Notices Information for United States UsersInformation for Canadian Users IC notice SX-500  FCC ID N6C-SX10WGInformation for European Users SX-500 Declaration of Conformity CE SX-500Appendix E Silex Contact Information Silex Technology America, IncSilex Technology Europe GmbH Silex Technology Beijing, IncSilex Technology America, Inc

SX-500-1402 specifications

The Silex Technology SX-500-1402 is an advanced industrial wireless module designed for seamless integration into various applications requiring high-performance wireless connectivity. This module is particularly renowned for its robust features, making it ideal for use in automation, healthcare, and smart city applications.

One of the main features of the SX-500-1402 is its dual-band Wi-Fi capability, which operates on both 2.4 GHz and 5 GHz frequencies. This not only provides flexibility for different environments but also enhances the overall performance by reducing interference and optimizing data throughput. The module supports Wi-Fi 5 (802.11ac), enabling high-speed data transmission and ensuring reliable connectivity even in crowded environments.

Another key aspect of the SX-500-1402 is its compact size and lightweight design, offering an excellent solution for space-constrained applications. The module features a PCB form factor that facilitates easy integration into diverse devices while minimizing additional footprint.

The SX-500-1402 boasts advanced security features, including WPA3 support, ensuring encryption and secure data transmission across networks. This is a critical requirement for applications in healthcare and finance, where safeguarding sensitive information is paramount. Furthermore, the module supports secure boot and firmware updates, further enhancing its security posture.

In terms of power management, the Silex module is designed for energy efficiency, making it suitable for battery-powered applications. It features various power-saving modes that help to extend battery life without compromising performance, enabling devices to operate for longer periods without frequent recharging.

The SX-500-1402 also integrates seamlessly with diverse host interfaces, such as UART, SPI, and I2C, facilitating easy connectivity to microcontrollers and other devices. This versatility makes it an ideal choice for developers looking to prototype and bring their IoT solutions to market swiftly.

Key specifications of the SX-500-1402 include a maximum data rate of 867 Mbps in the 5 GHz band, operating temperature range from -20 to 70 degrees Celsius, and an extended range due to its MIMO (Multiple Input, Multiple Output) technology, which further enhances performance in environments with obstacles.

In summary, the Silex Technology SX-500-1402 is an exceptional choice for applications requiring reliable, high-speed wireless communication. With its advanced features, robust security measures, and versatile integration options, it stands out as a premier solution in the industrial wireless module landscape.