Chapter 5: RAID Monitoring and Maintenance
Rebuild Settings
Beeper –
Figure 80. Rebuild Settings in Information View.
Enable Hot Spare Disk – Enables a spare drive not assigned to the array to automatically replace a failed drive in the array. You must also enable Auto Rebuild for this feature to be effective.
Enable Auto Rebuild – Enables automatic rebuilding of a
Enable Hot Swap Disk – Allows you to replace a faulty disk drive without shutting down the system. This feature works with an externally replaceable disk drive enclosure such as the Promise SuperSwap.
Rebuild Setting – Allocates system resources between rebuilding the array and responding to read/write commands from the computer system.
A High setting assigns most of the system resources to rebuilding. Rebuilding goes faster, restoring redundancy sooner but read/write requests are handled slower.
A Low setting assigns most of the system resources to handling read/write requests. Read/write requests are handled at nearly normal speed while the rebuild takes longer.
79