NCR 7883 Special Installations, RS-232 Peripherals, RealScan 7892 Bi-Modal Presentation Scanner

Page 12

NCR RealScan 7883 Installation and Owner Guide

Special Installations

RS-232 Peripherals

The RealScan 7883 includes two auxiliary RS-232 ports. This permits other peripheral devices to connect to the host terminal through the RealScan 7883, eliminating the need of the host terminal having additional RS-232 ports. Programming of the ports is required. The various sequences and the action taken is given below for handheld scanners. All options should be programmed because the scanner could have been previously programmed for a different option.

Programming the RealScan 7883

Program Mode

4 0 1

Enables Hand Held port

** Port Selection **

4

0

2

Enables right hand port (Sensormatic)

4

0

3

Enables left hand port (Scale, closest to arrow/PS connection)

** 7883 Good Tone with auxiliary input **

4 0 4

Disables 7883 Tone with each scanned input

4 0 5

Enables 7883 Tone with each scanned input

** Scanner selection **

 

4 0 6

7835/7836/7837, programming information provided

4 0 7

Symbol LS4000, must be programmed properly

5 5 1

Enables port for 7832 format, programming information provided

Save & Reset

 

A typical use of this feature is to connect a hand-held scanner for scanning items too large to place on the checkstand. The 7892 may be programmed for compatibility with either the 7837 or 7832.

Additional Information

NCR RealScan 7892 Bi-Modal Presentation Scanner User Guide, 5005-0000-1182

NCR RealScan 7832 Operator’s Guide, 497-0434255

NCR RealScan 7837 Imaging Scanner User’s Guide, 497-0427357

RealScan 7892 Bi-Modal Presentation Scanner

You can connect a RealScan 7892 Bi-Modal Presentation Scanner to either Auxiliary RS-232 Port on

12 of 75

04/04

497-0424789 Release F

Image 12
Contents RealScan Installation and Owner Guide Information Products RSD-AtlantaContents Laser Safety Label Laser Module Label Laser Power Revision Record Obtaining Additional Information Obtaining Technical AssistanceNCR RealScan 7883 Mountings Installation Instructions StepInstalling Power Supply and Interface Cables Connecting the Cables to an NCR RealScanStandard Interface Connection USB Interface Connection IBM HID Auxiliary RS-232 Port NCR RealScan 7835/7836Special Installations RS-232 PeripheralsRealScan 7892 Bi-Modal Presentation Scanner Programming the RealScan RealScan 7832 ProgrammingRealScan 7837 Programming Factory Default RS232, 7 DATA, 1 STOP, Space Parity Setting Program Parameters and Verifying Host Connection Turning on the RealScanFlash Latest Firmware Programming the RealScan Programming Defaults UPC/EANBaud Rate Programming for USB Connection RS-232 CommunicationsIBM Communications Reduced Space Symbology RSS-14 StackedRSS Expanded RSS Expanded StackedMaking Other Program Changes Enabling RSSDisabling RSS Scan Sample Tags UPC-ADetermining Label Quality 01234 5 678 9Setting RealScan 7883 Scan Zone Scan Zone Adjusting ScrewHorizontal Pass-by Scanning Vertical Pass-by ScanningVertical Presentation Scanning from Top Vertical Presentation Scanning from BottomMounting the RealScan Rubber FeetPlastic Top Plate Plastic Top Plate ScannerC Latch Clip Mounting Screw Vertical Mounting Bracket Checkstand Cutout Checkpoint CableCable Clamps Operating the Scanner Cleaning the Scanner Correcting Scanner Problems Green Status Tones Problem IndicatorThen supply again Interface Connector Interface InformationMost Common Interface Cables Communications Protocol Programming WorksheetCommunications Protocol Options 4 and B not supported yet Features Checkstand Hole RealScan 7883 Horizontal MountCheckstand Hole RealScan 7883 Flat Mount Ventilation RequirementsElectrical Wiring Installation Type Input Voltage L1, L2 Circuit BreakersNCR RealScan Mettler Toledo Scale, & Sensormatic ScanMaxTMHS NCR ComponentsMettler Toledo Components Sensormatic ComponentsSystem Construction Right-TO-Left ScanningLeft-To-Right Scanning Configuring the Scale Installing the Scanner Connecting Sensormatic Components Routing the Cables Completing the Installation Calibrating the Mettler Toledo Scale NCR RealScan 7883 Installation and Owner Guide Sensormatic Deactivation Indicators Sensormatic Programmable FunctionsTroubleshooting Scanner ProblemsScale Problems Sensormatic Deactivation Programming Worksheets Communications ProtocolGood Read Tone Timers Bar CodesCode Bar Codes Label Identifiers Unique Identifier20 RS-232 Parameters 21 RS-232 Parameters22 RS-232 Prefix Byte 23 RS-232 Terminator Byte24 RS-232 Communications Options Miscellaneous Parameters RealScan Ascii Code Chart Regulatory Information Identification LabelsCE Mark Applicability NCR Corporation Duluth, GaDeclaration of Conformity Laser Safety Laser Safety LabelLaser Module Label Laser Power Volume Adjustment ResetDefault Programming TagsProgramming Mode Save and ResetEnd Diagnostic Mode RS-232 Temporary Service ModeAbort Reset Tallies ModeFirmware Flashing HexR0050 R0053 Hex a Hex B Hex CHex D Hex E Hex F