Hand Held Products 3060 Code 39/Code 32 Settings, Code 39 Family Settings, Code 39 Min. Length

Page 27

Programming the Scanner

Symbology Programming

Code 39/Code 32 Settings

PROGRAM

 

 

 

 

 

END(Exit)

 

 

 

 

 

 

 

Family Code Selection

 

 

Parameter Selection

 

 

Option Code

Code 39 Family Settings

 

 

Select Standard Code 39

 

0

 

 

 

Select Full ASCII Code 39*

 

1

 

 

 

Select Code 32 (Italian Pharmaceutical)

 

2

 

 

 

 

 

 

 

 

 

 

Disable start/stop symbol transmission

 

 

3

 

 

 

Enable start/stop symbol transmission

 

 

4

 

 

 

Disable Code 32 leading A transmission

 

5

 

 

 

Enable Code 32 leading A transmission

 

6

 

 

 

 

 

 

 

 

 

 

Disable MOD 43 check digit verification

 

 

7

 

 

 

Enable MOD 43 check digit verification

 

 

8

 

 

 

Disable check digit transmission

 

9

 

 

 

Enable check digit transmission

 

 

A

Code 39 Min. Length

 

 

Default (04)

 

 

(2 digits)

 

 

 

Minimum length

 

 

 

 

 

 

 

 

 

 

 

 

Scan 2 digits from the option code chart in the Appendix.

 

 

 

 

 

 

 

 

 

 

Code 39 Max. Length

 

 

Default (99)

 

 

(2 digits)

 

 

 

Maximum length

 

 

 

 

 

 

 

 

 

 

 

 

Scan 2 digits from the option code chart in the Appendix.

 

 

 

 

 

 

 

 

 

 

FACTORY DEFAULT

*Selecting Full ASCII Code 39 disables Code 32 (both options may not be enabled at the same time). Code 39 and full ASCII may be enabled at the same time, and Code 32 and Code 39 standard my be enabled at the same time.

3-13

Image 27
Contents Page Disclaimer FCC Class a Compliance Statement Canadian Notice Statement of Agency CompliancePage Table of Contents Page About This Manual Getting StartedN344 HHP SET Getting Started PC/AT, PS/2 Keyboard Wedge Keyboard Wedge InterfacePC/AT Keyboard Wedge Connection Keyboard Wedge InstallationRS-232 Serial Interface PS/2 Keyboard Wedge ConnectionStandard RS-232 Pinouts RS-232 Interface InstallationPin D-sub RS-232 Female Connector RS-232 Serial InterfaceUSB Keyboard Interface USB Keyboard InterfaceUSB Keyboard Interface Connection HHP SET at a Glance Check Software Revision Full-featured Data EditorVia HHP SET Via Bar Code Programming MenuCheck Software Revision Software Installation On-screen ConfigurationConfiguration Download and Upload Program Field UpgradeAdvanced Data Verification Data EditorData Format Editor General Transmission ControlActual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7 Configuration ProcedureSelect Using Match Application ExampleProgramming the Scanner Family Code System CommandProgramming Procedures Bar Code Programming MenuProgram & End System List & Master DefaultExample Selection Flow DiagramsHost Interface Selection ENDExitHost Interface Selection User Defined Code ID User Defined Code ID Symbology ProgrammingSymbol ID 1 character Symbol ID 2 characterCode ID Transmission and Symbology Enable Symbology EnableCode ID Transmission Code 39 Max. Length Code 39/Code 32 SettingsCode 39 Family Settings Code 39 Min. LengthCodabar Max. Length Codabar/NW-7 SettingCodabar Settings Codabar Min. LengthUPC Family Settings UPC-A & UPC-E SettingEAN/JAN/CAN & IATASetting EAN/CAN/JAN SettingsIata Settings Code 2 of 5 Min. Length Code 2 of 5 Family & German Post Code SettingCode 2 of 5 Settings German Postal SettingCode 11 & Code 93 Setting MSI/Plessey, Code 128 & UCC/EAN 128 Setting UK/Plessey & Telepen Setting Keyboard Layout Language Setting Keyboard Interface ControlKeyboard Layout Record Suffix, Preamble, Postamble & Delay Setting Caps Lock Control Caps Lock Control & Emulation SettingFunction Key Emulation Key Pad EmulationRecord Suffix, Handshaking & Time Out Setting Serial Interface ControlSTX/ETX Control Handshaking Protocol Baud Rate & Data Frame SettingData Frame Time Out ControlNarrow/Wide Ratio, Code 39 Emulation Wand Emulation ControlTrigger Modes Scanning Tolerance Printing Quality Control Diagnostic Mode Test ReadingPrinting Quality Control Operation ModeOperation Control Trigger Mode, Buzzer Tone, Scanning TolerancePulse Driven Duty Reread DelayAuto Power Off Duration Advanced Operation ControlScan Voting Reread Delay, Scan VotingReread Delay Dollar Sign ControlData Pass Control Preamble, Postamble, Data Length & Symbol ID TransCondensed Data Editor Data Length TransmissionData Formatter Data Verifier Settings 2nd Replacement Data Replacer Settings1st Replacement 3rd Replacement2nd Organization Data Organizer SettingsOrganizer Control 1st OrganizationSelect a Bar Code Symbology Programming ProcedurePosition Calculation Data Verifier Data OrganizerData Replacer Obtaining Factory Service Main OfficeUnited Kingdom Office Application Support Asia Pacific OfficeJapan Office Latin America OfficeLatin America EuropeAsia Limited Warranty Limited Warranty Appendix a IllustrationDescription RS-232 Serial Wedge Cable Converter Descriptions Beeping Buzzer Tone Beeping Indications1DH Down 0EH 1EH Left 0FH 1FH Right Keyboard Function Code TableAscii Input Shortcut ExampleHEX/ASCII Reference Table Bar Code Command Menu Master DefaultSystem List Sample Bar Codes Factory Default Setting Bar Code System Command