Hand Held Products 3060, 3220, 3080 manual Ascii Input Shortcut, Example, HEX/ASCII Reference Table

Page 63

Appendix A

ASCII Input Shortcut

To configure the user definable parameters of the scanner via the programming bar codes, you will be asked to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details.

Example:

If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$.” The configuration procedure is listed below for reference.

Scan the system command – PROGRAM listed on page 3-22 to enter programming mode.

Scan family code – PREAMBLE to select this family.

In the Hex/ASCII Table, you will find the HEX value of “$” is 24.

Scan the option code – 2 listed on the foldout back cover. Scan the option code – 4 listed on the foldout back cover. Scan the system command – FIN (Finish) to terminate Preamble setting.

Scan the system command – End to exit the programming mode for normal operation.

HEX/ASCII Reference Table

 

0

1

2

3

4

5

6

7

0

NUL

DLE

SPACE

0

@

P

`

p

1

SOH

DC1

!

1

A

Q

a

q

2

STX

DC2

"

2

B

R

b

r

3

ETX

DC3

#

3

C

S

c

s

4

EOT

DC4

$

4

D

T

d

t

5

ENQ

NAK

%

5

E

U

e

u

6

ACK

SYN

&

6

F

V

f

v

7

BEL

ETB

'

7

G

W

g

w

8

BS

CAN

(

8

H

X

h

x

9

HT

EM

)

9

I

Y

i

y

A

LF

SUB

*

:

J

Z

j

z

B

VT

ESC

+

;

K

[

k

{

C

FF

FS

,

<

L

\

l

D

CR

GS

-

=

M

]

m

}

E

SO

RS

.

>

N

^

n

~

F

SI

US

/

?

O

_

o

DEL

Example : ASCII “A” HEX “41;” ASCII “a” “61” : High Byte of HEX Value

: Low Byte of HEX Value

A-6

Image 63
Contents Page Disclaimer FCC Class a Compliance Statement Canadian Notice Statement of Agency CompliancePage Table of Contents Page About This Manual Getting StartedN344 HHP SET Getting Started PC/AT, PS/2 Keyboard Wedge Keyboard Wedge InterfacePC/AT Keyboard Wedge Connection Keyboard Wedge InstallationRS-232 Serial Interface PS/2 Keyboard Wedge ConnectionStandard RS-232 Pinouts RS-232 Interface InstallationPin D-sub RS-232 Female Connector RS-232 Serial InterfaceUSB Keyboard Interface USB Keyboard InterfaceUSB Keyboard Interface Connection HHP SET at a Glance Check Software Revision Full-featured Data EditorVia HHP SET Via Bar Code Programming MenuCheck Software Revision Software Installation On-screen ConfigurationConfiguration Download and Upload Program Field UpgradeAdvanced Data Verification Data EditorData Format Editor General Transmission ControlActual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7 Configuration ProcedureSelect Using Match Application ExampleProgramming the Scanner Family Code System CommandProgramming Procedures Bar Code Programming MenuProgram & End System List & Master DefaultExample Selection Flow DiagramsHost Interface Selection ENDExitHost Interface Selection User Defined Code ID User Defined Code ID Symbology ProgrammingSymbol ID 1 character Symbol ID 2 characterCode ID Transmission and Symbology Enable Symbology EnableCode ID Transmission Code 39 Max. Length Code 39/Code 32 SettingsCode 39 Family Settings Code 39 Min. LengthCodabar Max. Length Codabar/NW-7 SettingCodabar Settings Codabar Min. LengthUPC Family Settings UPC-A & UPC-E SettingEAN/JAN/CAN & IATASetting EAN/CAN/JAN SettingsIata Settings Code 2 of 5 Min. Length Code 2 of 5 Family & German Post Code SettingCode 2 of 5 Settings German Postal SettingCode 11 & Code 93 Setting MSI/Plessey, Code 128 & UCC/EAN 128 Setting UK/Plessey & Telepen Setting Keyboard Layout Language Setting Keyboard Interface ControlKeyboard Layout Record Suffix, Preamble, Postamble & Delay Setting Caps Lock Control Caps Lock Control & Emulation SettingFunction Key Emulation Key Pad EmulationRecord Suffix, Handshaking & Time Out Setting Serial Interface ControlSTX/ETX Control Handshaking Protocol Baud Rate & Data Frame SettingData Frame Time Out ControlNarrow/Wide Ratio, Code 39 Emulation Wand Emulation ControlTrigger Modes Scanning Tolerance Printing Quality Control Diagnostic Mode Test ReadingPrinting Quality Control Operation ModeOperation Control Trigger Mode, Buzzer Tone, Scanning TolerancePulse Driven Duty Reread DelayAuto Power Off Duration Advanced Operation ControlScan Voting Reread Delay, Scan VotingReread Delay Dollar Sign ControlData Pass Control Preamble, Postamble, Data Length & Symbol ID TransCondensed Data Editor Data Length TransmissionData Formatter Data Verifier Settings 2nd Replacement Data Replacer Settings1st Replacement 3rd Replacement2nd Organization Data Organizer SettingsOrganizer Control 1st OrganizationSelect a Bar Code Symbology Programming ProcedurePosition Calculation Data Verifier Data OrganizerData Replacer Obtaining Factory Service Main OfficeUnited Kingdom Office Application Support Asia Pacific OfficeJapan Office Latin America OfficeLatin America EuropeAsia Limited Warranty Limited Warranty Appendix a IllustrationDescription RS-232 Serial Wedge Cable Converter Descriptions Beeping Buzzer Tone Beeping Indications1DH Down 0EH 1EH Left 0FH 1FH Right Keyboard Function Code TableAscii Input Shortcut ExampleHEX/ASCII Reference Table Bar Code Command Menu Master DefaultSystem List Sample Bar Codes Factory Default Setting Bar Code System Command