Hand Held Products 3080, 3060, 3220 Keyboard Interface Control, Keyboard Layout Language Setting

Page 35

Programming the Scanner

Keyboard Interface Control

Keyboard Layout (Language) Setting

 

PROGRAM

 

 

 

END(Exit)

 

 

 

 

 

 

 

Family Code Selection

 

Parameter Selection

 

Option Code

 

Keyboard Layout

 

USA (QWERTY)

 

00

 

 

 

France (AZERTY)

 

01

 

 

 

Germany (QWERTZ)

 

02

 

 

 

United Kingdom - UK (QWERTY)

 

03

 

 

 

Canadian French (QWERTY)

 

04

 

 

 

Spain (QWERTY)

 

05

 

 

 

Sweden/Finland (QWERTY)

 

06

 

 

 

Portugal (QWERTY)

 

07

 

 

 

Norway (QWERTY)

 

08

 

 

 

Latin America (QWERTY)

 

09

 

The “Universal Selection” is only for

 

 

PC/AT, PS/VP, PS/2 and IBM

 

Italy (QWERTY)

 

10

 

compatibles in DOS or Windows

 

Netherlands (QWERTY)

 

11

 

environment that can perform unique

 

Denmark (QWERTY)

 

12

 

output without Caps Lock on/off (Output

 

Belgium (AZERTY)

 

13

 

Style) concern. All transmitted data will

 

 

 

follow the original full ASCII form. You

 

Switzerland-Germany (QWERTY)

 

14

 

also need not worry about the

 

Iceland (QWERTY)

 

15

 

upper/lower case control.

 

Universal (only available for IBM PC/AT, PS/VP in MS DOS and Windows Mode)

 

99

 

 

 

 

 

 

 

 

 

 

FACTORY DEFAULT

Please refer to the HEX/ASCII Table listed in Appendix A to determine HEX codes for characters, symbols, and functions to be used as premble or postamble. To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-23 first.

Keyboard Interface Message String :

Preamble

Data Length

Prefix Symbol ID

Scanned Data

Suffix Symbol ID

Postamble

Record Suffix

1-15 characters

2-3 digits

1 or 2 characters

variable length

1 or 2 characters

1-15 characters

1 character

3-21

Image 35
Contents Page Disclaimer FCC Class a Compliance Statement Canadian Notice Statement of Agency CompliancePage Table of Contents Page About This Manual Getting StartedN344 HHP SET Getting Started PC/AT, PS/2 Keyboard Wedge Keyboard Wedge InterfacePC/AT Keyboard Wedge Connection Keyboard Wedge InstallationRS-232 Serial Interface PS/2 Keyboard Wedge ConnectionStandard RS-232 Pinouts RS-232 Interface InstallationPin D-sub RS-232 Female Connector RS-232 Serial InterfaceUSB Keyboard Interface Connection USB Keyboard InterfaceUSB Keyboard Interface HHP SET at a Glance Check Software Revision Full-featured Data EditorVia HHP SET Via Bar Code Programming MenuCheck Software Revision Software Installation On-screen ConfigurationConfiguration Download and Upload Program Field UpgradeAdvanced Data Verification Data EditorData Format Editor General Transmission ControlActual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7 Configuration ProcedureSelect Using Match Application ExampleProgramming the Scanner Family Code System CommandProgramming Procedures Bar Code Programming MenuProgram & End System List & Master DefaultExample Selection Flow DiagramsHost Interface Selection Host Interface SelectionENDExit User Defined Code ID User Defined Code ID Symbology ProgrammingSymbol ID 1 character Symbol ID 2 characterCode ID Transmission Code ID Transmission and Symbology EnableSymbology Enable Code 39 Max. Length Code 39/Code 32 SettingsCode 39 Family Settings Code 39 Min. LengthCodabar Max. Length Codabar/NW-7 SettingCodabar Settings Codabar Min. LengthUPC Family Settings UPC-A & UPC-E SettingIata Settings EAN/JAN/CAN & IATASettingEAN/CAN/JAN Settings Code 2 of 5 Min. Length Code 2 of 5 Family & German Post Code SettingCode 2 of 5 Settings German Postal SettingCode 11 & Code 93 Setting MSI/Plessey, Code 128 & UCC/EAN 128 Setting UK/Plessey & Telepen Setting Keyboard Layout Keyboard Layout Language SettingKeyboard Interface Control Record Suffix, Preamble, Postamble & Delay Setting Caps Lock Control Caps Lock Control & Emulation SettingFunction Key Emulation Key Pad EmulationSTX/ETX Control Record Suffix, Handshaking & Time Out SettingSerial Interface Control Handshaking Protocol Baud Rate & Data Frame SettingData Frame Time Out ControlNarrow/Wide Ratio, Code 39 Emulation Wand Emulation ControlTrigger Modes Scanning Tolerance Printing Quality Control Diagnostic Mode Test ReadingPrinting Quality Control Operation ModeOperation Control Trigger Mode, Buzzer Tone, Scanning TolerancePulse Driven Duty Reread DelayAuto Power Off Duration Advanced Operation ControlScan Voting Reread Delay, Scan VotingReread Delay Dollar Sign ControlData Pass Control Preamble, Postamble, Data Length & Symbol ID TransCondensed Data Editor Data Length TransmissionData Formatter Data Verifier Settings 2nd Replacement Data Replacer Settings1st Replacement 3rd Replacement2nd Organization Data Organizer SettingsOrganizer Control 1st OrganizationPosition Calculation Select a Bar Code SymbologyProgramming Procedure Data Replacer Data VerifierData Organizer United Kingdom Office Obtaining Factory ServiceMain Office Application Support Asia Pacific OfficeJapan Office Latin America OfficeAsia Latin AmericaEurope Limited Warranty Limited Warranty Appendix a IllustrationDescription RS-232 Serial Wedge Cable Converter Descriptions Beeping Buzzer Tone Beeping Indications1DH Down 0EH 1EH Left 0FH 1FH Right Keyboard Function Code TableHEX/ASCII Reference Table Ascii Input ShortcutExample System List Bar Code Command MenuMaster Default Sample Bar Codes Factory Default Setting Bar Code System Command