Hand Held Products 3060, 3220, 3080 manual Reread Delay, Scan Voting, Dollar Sign Control

Page 45

Programming the Scanner

Operation Control

Reread Delay, Scan Voting

PROGRAM

 

 

 

 

END(Exit)

 

 

 

 

 

 

 

 

Family Code Selection

 

Parameter Selection

 

Option Code

Reread Delay

 

Disable

Long time out duration

 

0

 

4

 

 

Immediate time out duration

Force Verification

 

1

 

5

 

 

Short time out duration

 

 

2

 

 

 

 

Medium time out duration

 

 

3

 

 

 

 

 

 

 

 

 

 

Scan Voting

 

None

4 times

 

0

 

4

 

 

1 time

5 times

 

1

 

5

 

 

2 times

 

 

2

 

 

 

 

3 times

 

 

3

 

 

Auto Power Off Duration

 

Short (around 2 seconds)

 

 

0

 

 

 

Medium (around 3-4 seconds)

 

 

1

 

 

 

Long (around 5-6 seconds)

 

 

2

 

 

 

Extremely long (around 7-8 seconds)

 

 

3

 

 

 

 

 

 

 

 

Pulse Driven Duty

 

1/2 duty cycle

 

 

0

 

 

 

2/3 duty cycle

 

 

1

 

 

 

3/4 duty cycle

 

 

2

 

 

 

4/5 duty cycle

 

 

3

 

 

 

 

 

 

 

 

Dollar Sign Control

 

Dollar sign output as “$”

 

 

0

 

 

 

Dollar sign output as “Japanese Yen”

 

 

1

 

 

 

 

 

 

 

 

 

FACTORY DEFAULT

The Debounce Time Control feature is available in the IT3220 (prior to software revision B) and in the VT3060/3080 (prior to software revision D). Units using later software revisions perform this function automatically.

3-31

Image 45
Contents Page Disclaimer FCC Class a Compliance Statement Canadian Notice Statement of Agency CompliancePage Table of Contents Page About This Manual Getting StartedN344 HHP SET Getting Started PC/AT, PS/2 Keyboard Wedge Keyboard Wedge InterfaceRS-232 Serial Interface Keyboard Wedge InstallationPS/2 Keyboard Wedge Connection PC/AT Keyboard Wedge ConnectionPin D-sub RS-232 Female Connector RS-232 Interface InstallationRS-232 Serial Interface Standard RS-232 PinoutsUSB Keyboard Interface USB Keyboard InterfaceUSB Keyboard Interface Connection Via HHP SET Check Software Revision Full-featured Data EditorVia Bar Code Programming Menu HHP SET at a GlanceConfiguration Download and Upload Software Installation On-screen ConfigurationProgram Field Upgrade Check Software RevisionData Format Editor Data EditorGeneral Transmission Control Advanced Data VerificationSelect Using Match Configuration ProcedureApplication Example Actual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7Programming the Scanner Programming Procedures System CommandBar Code Programming Menu Family CodeProgram & End System List & Master DefaultExample Selection Flow DiagramsHost Interface Selection ENDExitHost Interface Selection User Defined Code ID Symbol ID 1 character Symbology ProgrammingSymbol ID 2 character User Defined Code IDCode ID Transmission and Symbology Enable Symbology EnableCode ID Transmission Code 39 Family Settings Code 39/Code 32 SettingsCode 39 Min. Length Code 39 Max. LengthCodabar Settings Codabar/NW-7 SettingCodabar Min. Length Codabar Max. LengthUPC Family Settings UPC-A & UPC-E SettingEAN/JAN/CAN & IATASetting EAN/CAN/JAN SettingsIata Settings Code 2 of 5 Settings Code 2 of 5 Family & German Post Code SettingGerman Postal Setting Code 2 of 5 Min. LengthCode 11 & Code 93 Setting MSI/Plessey, Code 128 & UCC/EAN 128 Setting UK/Plessey & Telepen Setting Keyboard Layout Language Setting Keyboard Interface ControlKeyboard Layout Record Suffix, Preamble, Postamble & Delay Setting Function Key Emulation Caps Lock Control & Emulation SettingKey Pad Emulation Caps Lock ControlRecord Suffix, Handshaking & Time Out Setting Serial Interface ControlSTX/ETX Control Data Frame Baud Rate & Data Frame SettingTime Out Control Handshaking ProtocolNarrow/Wide Ratio, Code 39 Emulation Wand Emulation ControlTrigger Modes Scanning Tolerance Printing Quality Control Diagnostic Mode Test ReadingOperation Control Operation ModeTrigger Mode, Buzzer Tone, Scanning Tolerance Printing Quality ControlAuto Power Off Duration Reread DelayAdvanced Operation Control Pulse Driven DutyReread Delay Reread Delay, Scan VotingDollar Sign Control Scan VotingCondensed Data Editor Preamble, Postamble, Data Length & Symbol ID TransData Length Transmission Data Pass ControlData Formatter Data Verifier Settings 1st Replacement Data Replacer Settings3rd Replacement 2nd ReplacementOrganizer Control Data Organizer Settings1st Organization 2nd OrganizationSelect a Bar Code Symbology Programming ProcedurePosition Calculation Data Verifier Data OrganizerData Replacer Obtaining Factory Service Main OfficeUnited Kingdom Office Japan Office Asia Pacific OfficeLatin America Office Application SupportLatin America EuropeAsia Limited Warranty Limited Warranty Appendix a IllustrationDescription RS-232 Serial Wedge Cable Converter Descriptions Beeping Buzzer Tone Beeping Indications1DH Down 0EH 1EH Left 0FH 1FH Right Keyboard Function Code TableAscii Input Shortcut ExampleHEX/ASCII Reference Table Bar Code Command Menu Master DefaultSystem List Sample Bar Codes Factory Default Setting Bar Code System Command