Hand Held Products 3220 Condensed Data Editor, Preamble, Postamble, Data Length & Symbol ID Trans

Page 46

Programming the Scanner

Condensed Data Editor

Preamble, Postamble, Data Length & Symbol ID Trans.

 

PROGRAM

 

 

 

END(Exit)

 

 

 

 

 

 

 

 

 

Family Code Selection

 

Parameter Selection

 

Option Code

 

 

Preamble

 

None

 

FIN

 

 

 

 

1-15 characters (use hex value for each character)

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

 

 

 

Postamble

 

None

 

FIN

 

 

 

 

1-15 characters (use hex value for each character)

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

 

 

Data Length Transmission

 

Disable

0

 

 

 

 

Enable 2-digits data length transmission

1

 

 

 

 

 

 

 

 

 

 

 

If data length exceeds 99, 3-digit data length will be transmitted.

 

 

 

 

 

 

 

 

 

 

Code ID Transmission

 

Disable Code ID transmission

0

 

 

 

 

Enable prefix Code ID transmission

1

 

 

 

 

Enable suffix Code ID transmission

2

 

 

 

 

Enable both prefix and suffix Code ID transmission

3

 

 

 

 

 

 

 

 

Data Pass Control

 

Disable (format match required)

0

 

 

 

 

Enable (format match not required)

1

 

If data verifier is false, the original scanned bar code data will be transmitted.

The Data Editor is a very powerful, Artificial-Intelligence based data editing expert system provided specifically for the 3060B/3080B/3220 bar code scanners. Through the Data Editor, you can process the scanned data prior to transmitting in many ways, such as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It also allows you to arrange the transmission of scanned data to any specific format.

Due to the resources used by this system, the Full-feature Data Editor is only supported by HHP SET. Through HHP SET, all settings and configurations can be done on-screen, under Windows® 95/98/NT environment.

A Condensed Version Data Editor is provided here in the manual and is utilized by scanning the programming bar codes.

When Data Pass Control is disabled, all input data must conform to an edited format or the scanner does not transmit the input data to the host.

3-32

Image 46
Contents Page Disclaimer Statement of Agency Compliance FCC Class a Compliance Statement Canadian NoticePage Table of Contents Page Getting Started About This ManualN344 HHP SET Getting Started Keyboard Wedge Interface PC/AT, PS/2 Keyboard WedgePS/2 Keyboard Wedge Connection Keyboard Wedge InstallationRS-232 Serial Interface PC/AT Keyboard Wedge ConnectionRS-232 Serial Interface RS-232 Interface InstallationPin D-sub RS-232 Female Connector Standard RS-232 PinoutsUSB Keyboard Interface USB Keyboard InterfaceUSB Keyboard Interface Connection Via Bar Code Programming Menu Check Software Revision Full-featured Data EditorVia HHP SET HHP SET at a GlanceProgram Field Upgrade Software Installation On-screen ConfigurationConfiguration Download and Upload Check Software RevisionGeneral Transmission Control Data EditorData Format Editor Advanced Data VerificationApplication Example Configuration ProcedureSelect Using Match Actual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7Programming the Scanner Bar Code Programming Menu System CommandProgramming Procedures Family CodeSystem List & Master Default Program & EndSelection Flow Diagrams ExampleENDExit Host Interface SelectionHost Interface Selection User Defined Code ID Symbol ID 2 character Symbology ProgrammingSymbol ID 1 character User Defined Code IDSymbology Enable Code ID Transmission and Symbology EnableCode ID Transmission Code 39 Min. Length Code 39/Code 32 SettingsCode 39 Family Settings Code 39 Max. LengthCodabar Min. Length Codabar/NW-7 SettingCodabar Settings Codabar Max. LengthUPC-A & UPC-E Setting UPC Family SettingsEAN/CAN/JAN Settings EAN/JAN/CAN & IATASettingIata Settings German Postal Setting Code 2 of 5 Family & German Post Code SettingCode 2 of 5 Settings Code 2 of 5 Min. LengthCode 11 & Code 93 Setting MSI/Plessey, Code 128 & UCC/EAN 128 Setting UK/Plessey & Telepen Setting Keyboard Interface Control Keyboard Layout Language SettingKeyboard Layout Record Suffix, Preamble, Postamble & Delay Setting Key Pad Emulation Caps Lock Control & Emulation SettingFunction Key Emulation Caps Lock ControlSerial Interface Control Record Suffix, Handshaking & Time Out SettingSTX/ETX Control Time Out Control Baud Rate & Data Frame SettingData Frame Handshaking ProtocolWand Emulation Control Narrow/Wide Ratio, Code 39 EmulationTrigger Modes Diagnostic Mode Test Reading Scanning Tolerance Printing Quality ControlTrigger Mode, Buzzer Tone, Scanning Tolerance Operation ModeOperation Control Printing Quality ControlAdvanced Operation Control Reread DelayAuto Power Off Duration Pulse Driven DutyDollar Sign Control Reread Delay, Scan VotingReread Delay Scan VotingData Length Transmission Preamble, Postamble, Data Length & Symbol ID TransCondensed Data Editor Data Pass ControlData Formatter Data Verifier Settings 3rd Replacement Data Replacer Settings1st Replacement 2nd Replacement1st Organization Data Organizer SettingsOrganizer Control 2nd OrganizationProgramming Procedure Select a Bar Code SymbologyPosition Calculation Data Organizer Data VerifierData Replacer Main Office Obtaining Factory ServiceUnited Kingdom Office Latin America Office Asia Pacific OfficeJapan Office Application SupportEurope Latin AmericaAsia Limited Warranty Limited Warranty Appendix a IllustrationDescription RS-232 Serial Wedge Cable Converter Beeping Indications Descriptions Beeping Buzzer ToneKeyboard Function Code Table 1DH Down 0EH 1EH Left 0FH 1FH RightExample Ascii Input ShortcutHEX/ASCII Reference Table Master Default Bar Code Command MenuSystem List Sample Bar Codes Bar Code System Command Factory Default Setting