Programming the Scanner
Wand Emulation Control
|
|
|
|
|
|
|
|
|
|
| |
PROGRAM |
| ♦ Output Polarity, Signal State, Margin/Module Time, |
| END(Exit) |
| ||||||
| Narrow/Wide Ratio, Code 39 Emulation♦ |
|
|
| |||||||
|
|
|
|
|
|
|
| ||||
Family Code Selection |
|
| Parameter Selection |
| Option Code | ||||||
Output Polarity |
| High level (5Vdc) on Bar (low level on Space) |
|
| 0 |
| |||||
|
|
| Low level (0Vdc) on Bar (high level on Space) |
|
| 1 |
| ||||
|
|
|
|
|
|
|
|
|
| ||
|
|
| Determine the output voltage level for both bar and space. |
|
|
|
| ||||
Initial Signal State |
| High Level (5Vdc) |
|
| 0 |
| |||||
|
|
| Low Level (0Vdc) |
|
| 1 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Determine the initial state of output voltage level. |
|
|
|
|
|
| ||
Margin Time |
| 10 mseconds |
| 30 mseconds | 0 |
| 4 | ||||
|
|
| 15 mseconds |
| 50 mseconds | 1 |
| 5 | |||
|
|
| 20 mseconds |
| 100 mseconds | 2 |
| 6 | |||
|
|
| 25 mseconds |
|
| Delay time before data transmission | 3 |
|
| ||
|
|
|
|
|
|
|
| ||||
Module Time |
| Extremely short |
| Long | 0 |
| 3 | ||||
|
|
| Short |
|
|
| 1 |
|
| ||
|
|
| Medium |
|
| Time base of minimum narrow bar | 2 |
|
| ||
|
|
|
|
|
|
|
|
| |||
Narrow/Wide Ratio | 1:2 |
|
|
|
| 0 |
| ||||
|
| 1:2.5 |
|
|
|
| 1 |
| |||
|
| 1:3 |
|
|
|
| 2 |
| |||
|
|
|
|
|
|
| |||||
Code 39 Emulation |
| Disable standard Code 39 emulation |
|
| 0 |
| |||||
|
|
| Enable standard Code 39 skip emulation |
|
| 1 |
| ||||
|
|
| Enable standard Code 39 replace emulation |
|
| 2 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
FACTORY DEFAULT
[ Code 39 Skip ] : When this option is selected, all scanned data will be translated as Standard Code 39 wand emulation output. If any lowercase characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.
[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set will be translated as Space.