Hand Held Products 3060, 3220, 3080 manual Data Verifier Settings

Page 48

Programming the Scanner

Condensed Data Editor

Data Verifier Settings

PROGRAM

 

 

 

 

 

 

 

 

END(Exit)

 

 

 

 

 

 

 

 

 

 

Family Code Selection

 

 

Parameter Selection

 

 

Option Code

 

 

2nd Option Code

Verifier Control

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Select one bar code symbology

 

 

(2 digits)

 

 

automatic termination

 

 

 

Select all bar code symbologies

 

00

 

 

automatic termination

 

 

 

 

 

 

 

 

 

 

Identified Data Length

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit decimal

 

 

 

 

 

 

 

 

 

value)

 

 

 

 

 

 

Determine the identified data length for verification.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st Identified Character

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit HEX

 

 

[00-7F]

 

 

 

 

 

 

value)

 

 

 

 

 

 

2-digits checking position; 1 identified character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd Identified Character

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit HEX

 

 

[00-7F]

 

 

 

 

 

 

value)

 

 

 

 

 

 

2-digits checking position; 1 identified character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3rd Identified Character

 

 

Disable

 

 

FIN

 

 

 

 

 

 

Enable

 

 

(2-digit HEX

 

 

[00-7F]

 

 

 

 

 

 

value)

 

 

 

 

 

 

2-digits checking position; 1 identified character

 

 

position

 

 

 

 

 

 

 

 

 

 

 

 

 

The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.

All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the scanner will not transmit the data to the host computers, but will instead issue 3 long beeps for verification error and skip the scanned data.

The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID, or Record Suffix. Please refer to page 3-37 for information about the “Bar Code Selection” and “Position Calculation” of Data Verifier.

To determine the hex value for the “Character,” refer to the HEX/ASCII Table on page A-6. Refer to page 3-12 for 2-digit symbology option code.

3-34

Image 48
Contents Page Disclaimer Statement of Agency Compliance FCC Class a Compliance Statement Canadian NoticePage Table of Contents Page Getting Started About This ManualN344 HHP SET Getting Started Keyboard Wedge Interface PC/AT, PS/2 Keyboard WedgeKeyboard Wedge Installation RS-232 Serial InterfacePS/2 Keyboard Wedge Connection PC/AT Keyboard Wedge ConnectionRS-232 Interface Installation Pin D-sub RS-232 Female ConnectorRS-232 Serial Interface Standard RS-232 PinoutsUSB Keyboard Interface USB Keyboard InterfaceUSB Keyboard Interface Connection Check Software Revision Full-featured Data Editor Via HHP SETVia Bar Code Programming Menu HHP SET at a GlanceSoftware Installation On-screen Configuration Configuration Download and UploadProgram Field Upgrade Check Software RevisionData Editor Data Format EditorGeneral Transmission Control Advanced Data VerificationConfiguration Procedure Select Using MatchApplication Example Actual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7Programming the Scanner System Command Programming ProceduresBar Code Programming Menu Family CodeSystem List & Master Default Program & EndSelection Flow Diagrams ExampleHost Interface Selection ENDExitHost Interface Selection User Defined Code ID Symbology Programming Symbol ID 1 characterSymbol ID 2 character User Defined Code IDCode ID Transmission and Symbology Enable Symbology EnableCode ID Transmission Code 39/Code 32 Settings Code 39 Family SettingsCode 39 Min. Length Code 39 Max. LengthCodabar/NW-7 Setting Codabar SettingsCodabar Min. Length Codabar Max. LengthUPC-A & UPC-E Setting UPC Family SettingsEAN/JAN/CAN & IATASetting EAN/CAN/JAN SettingsIata Settings Code 2 of 5 Family & German Post Code Setting Code 2 of 5 SettingsGerman Postal Setting Code 2 of 5 Min. LengthCode 11 & Code 93 Setting MSI/Plessey, Code 128 & UCC/EAN 128 Setting UK/Plessey & Telepen Setting Keyboard Layout Language Setting Keyboard Interface ControlKeyboard Layout Record Suffix, Preamble, Postamble & Delay Setting Caps Lock Control & Emulation Setting Function Key EmulationKey Pad Emulation Caps Lock ControlRecord Suffix, Handshaking & Time Out Setting Serial Interface ControlSTX/ETX Control Baud Rate & Data Frame Setting Data FrameTime Out Control Handshaking ProtocolWand Emulation Control Narrow/Wide Ratio, Code 39 EmulationTrigger Modes Diagnostic Mode Test Reading Scanning Tolerance Printing Quality ControlOperation Mode Operation ControlTrigger Mode, Buzzer Tone, Scanning Tolerance Printing Quality ControlReread Delay Auto Power Off DurationAdvanced Operation Control Pulse Driven DutyReread Delay, Scan Voting Reread DelayDollar Sign Control Scan VotingPreamble, Postamble, Data Length & Symbol ID Trans Condensed Data EditorData Length Transmission Data Pass ControlData Formatter Data Verifier Settings Data Replacer Settings 1st Replacement3rd Replacement 2nd ReplacementData Organizer Settings Organizer Control1st Organization 2nd OrganizationSelect a Bar Code Symbology Programming ProcedurePosition Calculation Data Verifier Data OrganizerData Replacer Obtaining Factory Service Main OfficeUnited Kingdom Office Asia Pacific Office Japan OfficeLatin America Office Application SupportLatin America EuropeAsia Limited Warranty Limited Warranty Appendix a IllustrationDescription RS-232 Serial Wedge Cable Converter Beeping Indications Descriptions Beeping Buzzer ToneKeyboard Function Code Table 1DH Down 0EH 1EH Left 0FH 1FH RightAscii Input Shortcut ExampleHEX/ASCII Reference Table Bar Code Command Menu Master DefaultSystem List Sample Bar Codes Bar Code System Command Factory Default Setting