Hand Held Products 3080, 3060, 3220 manual Data Formatter

Page 47

Programming the Scanner

Condensed Data Editor

Data Formatter

PROGRAM

 

 

 

 

 

END(Exit)

 

 

 

 

 

 

 

Family Code Selection

 

Parameter Selection

 

Option Code

 

2nd Option Code

Formatter Control

 

Disable

 

FIN

 

 

 

 

Select one bar code symbology

 

(2 digits)

 

automatic termination

 

 

Select all bar code symbologies

 

00

 

automatic termination

 

 

 

 

 

 

 

1st Insertion

 

Disable

 

FIN

 

Hex value for each

 

 

Enable

 

(2 digits)

 

character, (FIN)

 

 

 

 

 

 

 

 

 

2-digits identified position; max. 3 insertion characters

 

position

 

1-3 characters to insert

 

 

 

 

 

 

 

2nd Insertion

 

Disable

 

FIN

 

Hex value for each

 

 

Enable

 

(2 digits)

 

character, (FIN)

 

 

 

 

 

 

 

 

 

2-digits identified position; max. 3 insertion characters

 

position

 

1-3 characters to insert

 

 

 

 

 

 

 

3rd Insertion

 

Disable

 

FIN

 

Hex value for each

 

 

Enable

 

(2 digits)

 

character, (FIN)

 

 

 

 

 

 

 

 

 

2-digits identified position; max. 3 insertion characters

 

position

 

1-3 characters to insert

 

 

 

 

 

 

 

4th Insertion

 

Disable

 

FIN

 

Hex value for each

 

 

Enable

 

(2 digits)

 

character, (FIN)

 

 

 

 

 

 

 

 

 

2-digits identified position; max. 3 insertion characters

 

position

 

1-3 characters to insert

 

 

 

 

 

 

 

FACTORY DEFAULT

The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computer or terminal. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.

If the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbolology ID or Record Suffix. All of the above programmable parameters perform the same function depending on your setting.

Please refer to page 3-37 for information about the “Bar Code Selection” and “Position Calculation” of the data formatter. To determine the hex value for the “Character,” refer to the HEX/ASCII Table on page A-6

Refer to page 3-12 for for the 2-digit symbology option code.

3-33

Image 47
Contents Page Disclaimer FCC Class a Compliance Statement Canadian Notice Statement of Agency CompliancePage Table of Contents Page About This Manual Getting StartedN344 HHP SET Getting Started PC/AT, PS/2 Keyboard Wedge Keyboard Wedge InterfacePC/AT Keyboard Wedge Connection Keyboard Wedge InstallationRS-232 Serial Interface PS/2 Keyboard Wedge ConnectionStandard RS-232 Pinouts RS-232 Interface InstallationPin D-sub RS-232 Female Connector RS-232 Serial InterfaceUSB Keyboard Interface Connection USB Keyboard InterfaceUSB Keyboard Interface HHP SET at a Glance Check Software Revision Full-featured Data EditorVia HHP SET Via Bar Code Programming MenuCheck Software Revision Software Installation On-screen ConfigurationConfiguration Download and Upload Program Field UpgradeAdvanced Data Verification Data EditorData Format Editor General Transmission ControlActual Bar Code label 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7 Configuration ProcedureSelect Using Match Application ExampleProgramming the Scanner Family Code System CommandProgramming Procedures Bar Code Programming MenuProgram & End System List & Master DefaultExample Selection Flow DiagramsHost Interface Selection Host Interface SelectionENDExit User Defined Code ID User Defined Code ID Symbology ProgrammingSymbol ID 1 character Symbol ID 2 characterCode ID Transmission Code ID Transmission and Symbology EnableSymbology Enable Code 39 Max. Length Code 39/Code 32 SettingsCode 39 Family Settings Code 39 Min. LengthCodabar Max. Length Codabar/NW-7 SettingCodabar Settings Codabar Min. LengthUPC Family Settings UPC-A & UPC-E SettingIata Settings EAN/JAN/CAN & IATASettingEAN/CAN/JAN Settings Code 2 of 5 Min. Length Code 2 of 5 Family & German Post Code SettingCode 2 of 5 Settings German Postal SettingCode 11 & Code 93 Setting MSI/Plessey, Code 128 & UCC/EAN 128 Setting UK/Plessey & Telepen Setting Keyboard Layout Keyboard Layout Language SettingKeyboard Interface Control Record Suffix, Preamble, Postamble & Delay Setting Caps Lock Control Caps Lock Control & Emulation SettingFunction Key Emulation Key Pad EmulationSTX/ETX Control Record Suffix, Handshaking & Time Out SettingSerial Interface Control Handshaking Protocol Baud Rate & Data Frame SettingData Frame Time Out ControlNarrow/Wide Ratio, Code 39 Emulation Wand Emulation ControlTrigger Modes Scanning Tolerance Printing Quality Control Diagnostic Mode Test ReadingPrinting Quality Control Operation ModeOperation Control Trigger Mode, Buzzer Tone, Scanning TolerancePulse Driven Duty Reread DelayAuto Power Off Duration Advanced Operation ControlScan Voting Reread Delay, Scan VotingReread Delay Dollar Sign ControlData Pass Control Preamble, Postamble, Data Length & Symbol ID TransCondensed Data Editor Data Length TransmissionData Formatter Data Verifier Settings 2nd Replacement Data Replacer Settings1st Replacement 3rd Replacement2nd Organization Data Organizer SettingsOrganizer Control 1st OrganizationPosition Calculation Select a Bar Code SymbologyProgramming Procedure Data Replacer Data VerifierData Organizer United Kingdom Office Obtaining Factory ServiceMain Office Application Support Asia Pacific OfficeJapan Office Latin America OfficeAsia Latin AmericaEurope Limited Warranty Limited Warranty Appendix a IllustrationDescription RS-232 Serial Wedge Cable Converter Descriptions Beeping Buzzer Tone Beeping Indications1DH Down 0EH 1EH Left 0FH 1FH Right Keyboard Function Code TableHEX/ASCII Reference Table Ascii Input ShortcutExample System List Bar Code Command MenuMaster Default Sample Bar Codes Factory Default Setting Bar Code System Command