1.Locate the secondary or standby CMC by using the RACADM getsysinfo command, or by using the Chassis Summary page in the web-based interface. Visually, the status indicator is solid blue on the primary or active CMC module and off on the standby or secondary CMC.

2.Update the firmware on the standby CMC first, using the web-based interface or RACADM.

3.Verify that the secondary or standby CMC’s firmware is at the requested level with the getsysinfo command or using the web-based interface.

4.After the standby CMC has rebooted, update the firmware on the active or primary CMC. Allow 10 minutes for the standby CMC to boot.

5.Verify that the active or primary CMC firmware is at the requested level using the getsysinfo command or using the web-based interface.

6.Once both CMCs are updated to the same firmware revision, use the cmcchangeover command to reset the CMC in the left slot as primary.

Downloading The CMC Firmware

Before beginning the firmware update, download the latest firmware version from support.dell.com, and save it to your local system. The following software components are included with your CMC firmware package:

Compiled CMC firmware code and data

Web-based interface, JPEG, and other user interface data files

Default configuration files

Use the Firmware Update page to update the CMC firmware to the latest revision. When you run the firmware update, the update retains the current CMC settings.

NOTE: The firmware update, by default, retains the current CMC settings. During the update process, you have the option to reset the CMC configuration settings back to the factory default settings.

Updating The CMC Firmware Using The Web-Based Interface

1.Log in to the web-based interface.

2.Click Chassis in the system tree.

3.Click the Update tab. The Updatable Components page is displayed.

4.On the Updatable Components page, click the CMC name. The Firmware Update page is displayed.

5.In the Value field, type the path on your management station or shared network where the firmware image file resides, or click Browse to navigate to the file location.

NOTE: The default CMC firmware image name is firmimg.cmc and this filename must not be changed. Ensure that you keep different firmware revisions separated as the file name always remains the same.

6.Click Update. A dialog box prompts to confirm the action.

7.Click Yes to continue. The firmware transfer process begins and the status displays the message Firmware Update in Progress. After the CMC update is complete, the CMC is reset and you must refresh the User Interface page to log in again.

Updating The CMC Firmware Using RACADM

1.Open a CMC command line console and log in.

2.Type:

racadm fwupdate -g -u - a <TFTP server IP address> -d <filepath> -m <cmc- activecmc-standby>

28

Image 28
Contents Regulatory Model BMX01 Page Contents Configuring The I/O Modules Installing Enclosure Components Technical Specifications Troubleshooting The EnclosureGetting Help About Your System System OverviewBlade Numbering Full Height Blades System Control-Panel Features Blade Numbering Quarter Height BladesLCD Module LCD Module Features LCD DisplayUsing The LCD Module Menus Configuration WizardCenter button Back-Panel Features Back-Panel FeaturesPower Supply Indicators Back-Panel Module Bay NumberingFan Module Indicators Indicator DescriptionPower to the system Power supply fault Icon IndicatorAvocent iKVM Analog Switch Module Optional Solid GreenAvocent Analog iKVM Switch Module Features And Indicators CMC Module Features CMC ModuleCondition Description CMC removal CMC Fail-Safe ModeCMC network cable Daisy-Chain CMC Network Connection System Messages Other Information You May NeedPage Initial CMC Network Configuration Initial Setup SequenceBefore You Begin Configuring The CMC Using The LCD Configuration Wizard Configuring The CMC Using a Management Station And CLIHttps//CMC IP address Logging In To The CMC Using The Web-Based InterfaceHttps//CMC IP addressport number Click Setup → Deploy Configuring iDRAC Networking Using The Web-Based InterfaceAdding And Managing CMC Users Configuring And Managing Power Setting The First Boot Device For ServersInstalling Or Updating The CMC Firmware Updating The CMC Firmware Using Racadm Updating The CMC Firmware Using The Web-Based InterfaceDownloading The CMC Firmware Configuring The Optional iKVM Switch Module Tiering The Avocent iKVM Switch From a Digital KVM SwitchTiering The Avocent iKVM Switch From An Analog KVM Switch Updating The iKVM FirmwareConfiguring The Analog Switch Click Setup → Devices → Device ModifyViewing And Selecting Servers FlexAddress FlexAddress PlusGeneral I/O Module Configuration Guidelines Network InformationConnectivity Fabric aFabric B Fabric CPowerEdge M610x Only Mezzanine CardsFull-Height Blades Half-Height BladesSupported I/O Module Configurations Module Port Mapping-Full-Height Blades Quarter-Height BladesStandard LOM Dual-Port Mapping Dual-Port Mezzanine CardsBlade Module Mezzanine Card C Port Mezzanine Card B Blade Module Blade Module Mezz1FabC Port Mezz2FabBMezz3FabC Port Mezz4FabB Blade Module Quad-Port Mezzanine Cards MezzFABCBlade n Module Port MappingHalf-Height Blades+8Port4 Example of I/O Module Port Assignments Half-Height Blade Blade n Integrated LOM1 Port n Integrated LOM2Module Port Mapping-Quarter-Height Blades Blade n ModuleDual-Port Mezzanine Cards Sleeve Module Sleeve Module Quad-Port Mezzanine Cards Modules-Switches Mellanox M4001F/M4001Q Infiniband Switch I/O ModuleDell PowerConnect KR 8024-k Switch Mellanox M4001F/M4001Q Infiniband Switch ModuleDell PowerConnect M8428-k 10 Gb Converged Network Switch Dell PowerConnect KR 8024-k SwitchMellanox M2401G DDR Infiniband Switch I/O Module Dell PowerConnect M8428-k 10 Gb Converged Network SwitchMellanox M3601Q QDR Infiniband Switch I/O Module Mellanox M2401G DDR Infiniband Switch ModuleCisco Catalyst Ethernet Switch I/O Modules Mellanox M3601Q QDR Infiniband Switch I/O ModuleDell PowerConnect M6348 1 Gb Ethernet Switch I/O Module Cisco Catalyst Ethernet Switch Module FeaturesDell PowerConnect M6220 Ethernet Switch I/O Module PowerConnect M6348 1 Gb Ethernet Switch I/O Module FeaturesDell PowerConnect M8024 10 Gb Ethernet Switch I/O Module PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M8024 10 Gb Ethernet Switch I/O Module Dell 8/4 Gbps FC SAN ModuleModules-Pass-Through Dell 4 Gbps Fibre Channel Pass-Through ModuleStatus/Identification Indicator InstalledDell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O ModuleDell 10 Gb Ethernet Pass-Through Module 10/100/1000 Mb Ethernet Pass-Through I/O ModuleBrocade M4424 SAN I/O Module 100/1000 Mb Ethernet Pass-Through I/O ModuleBrocade M4424 SAN I/O Module Brocade M5424 FC8 I/O Module Brocade M5424 FC8 I/O Module Module power indicator Page Recommended Tools Removing And Installing a BladeRemoving a Blade Blade handle Installing a Blade Removing And Installing a SleeveRemoving The Sleeve Power Supply Modules Installing The SleevePower Supply Blanks Removing a Power Supply ModulePower Cable Retention Clip Installing a Power Supply Module Fan ModulesInstalling a Fan Module Removing a Fan ModuleInstalling a CMC Module Removing a CMC ModuleClick the Power Management tab Select the Reset CMC warm boot buttonIKVM Module Installing An iKVM ModuleRemoving An iKVM Module Modules Removing An I/O ModuleEnclosure Bezel Installing An I/O ModuleRemoving The Enclosure Bezel Removing The Front Module Cage Assembly And Midplane Installing The Enclosure BezelEnclosure Midplane Front module cage assembly Enclosure Torx T20 screws Installing The Midplane And Front Module Cage Assembly Removing and Installing the MidplaneEnclosure Control Panel Assembly Removing The Control PanelInstalling The Control Panel Removing The LCD ModuleInstalling The LCD Module Removing and Installing the LCD ModulePage Troubleshooting The Enclosure Troubleshooting Enclosure ComponentsTroubleshooting a Wet Enclosure Troubleshooting Power Supply ModulesTroubleshooting The iKVM Module Troubleshooting Fan ModulesTroubleshooting I/O Modules Page Enclosure Specifications Power Supply ModuleOptional Avocent iKVM Module Chassis Management Controller ModuleModule Specifications PowerConnect M6220 Ethernet Switch ModuleBrocade FC8 Fibre Channel Switch Module Brocade FC4 Fibre Channel Switch ModuleMellanox M4001F/M4001Q Infiniband Switch I/O Module Mellanox Infiniband Switch ModuleGb Ethernet Pass-Through Module Fibre Channel Pass-Through ModuleDell PowerConnect M8024 10 Gb Ethernet switch I/O module Contacting Dell Visit support.dell.com