Dell BMX01 owner manual Recommended Tools, Removing And Installing a Blade, Removing a Blade

Page 71

4

Installing Enclosure Components

NOTE: To ensure proper operation and cooling, all bays in the enclosure must be populated at all times with either a module or with a blank.

Recommended Tools

You may need the following items to perform the procedures in this section:

#1 and #2 Phillips screwdrivers

T8, T10, T15, and T20 Torx drivers

Wrist grounding strap

Removing And Installing A Blade

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE: These procedures are applicable only for full-height and half-height blades. For information on removing and installing quarter-height blades from a sleeve, see the blade's Owner's Manual at support.dell.com/manuals.

Removing A Blade

1.Power down the blade using the operating system commands or the CMC, and ensure that the blade's power is off. When a blade is powered off, its front-panel power indicator is off.

CAUTION: Before removing full-height blades 3 or 4 or half-height blades 11 or 12, rotate the LCD panel to the storage position to prevent accidental damage to the LCD screen.

2.Press the release button on the blade handle.

3.Pull out the blade handle to unlock the blade from the enclosure.

CAUTION: If you are permanently removing the blade, install a blade blank(s). Operating the system for extended periods of time without a blade blank installed can cause the enclosure to overheat.

NOTE: A full-height blade requires two blade blanks.

4.Slide the blade out of the enclosure.

CAUTION: To protect the I/O connector pins, install the I/O connector covers any time a blade is removed from the enclosure.

NOTE: A full-height blade requires four connector covers and a half-height blade requires two connector covers.

5.Install the I/O connector cover over the I/O connector.

71

Image 71
Contents Regulatory Model BMX01 Page Contents Configuring The I/O Modules Installing Enclosure Components Getting Help Troubleshooting The EnclosureTechnical Specifications System Overview About Your SystemBlade Numbering Full Height Blades Blade Numbering Quarter Height Blades System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesCenter button Configuration WizardUsing The LCD Module Menus Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsPower supply fault Icon Indicator Fan Module IndicatorsIndicator Description Power to the systemSolid Green Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features And Indicators CMC Module CMC Module FeaturesCMC network cable CMC Fail-Safe ModeCondition Description CMC removal Daisy-Chain CMC Network Connection Other Information You May Need System MessagesPage Before You Begin Initial Setup SequenceInitial CMC Network Configuration Configuring The CMC Using a Management Station And CLI Configuring The CMC Using The LCD Configuration WizardHttps//CMC IP addressport number Logging In To The CMC Using The Web-Based InterfaceHttps//CMC IP address Adding And Managing CMC Users Configuring iDRAC Networking Using The Web-Based InterfaceClick Setup → Deploy Installing Or Updating The CMC Firmware Setting The First Boot Device For ServersConfiguring And Managing Power Downloading The CMC Firmware Updating The CMC Firmware Using The Web-Based InterfaceUpdating The CMC Firmware Using Racadm Updating The iKVM Firmware Configuring The Optional iKVM Switch ModuleTiering The Avocent iKVM Switch From a Digital KVM Switch Tiering The Avocent iKVM Switch From An Analog KVM SwitchClick Setup → Devices → Device Modify Configuring The Analog SwitchViewing And Selecting Servers FlexAddress Plus FlexAddressFabric a General I/O Module Configuration GuidelinesNetwork Information ConnectivityFabric C Fabric BHalf-Height Blades PowerEdge M610x OnlyMezzanine Cards Full-Height BladesSupported I/O Module Configurations Dual-Port Mezzanine Cards Module Port Mapping-Full-Height BladesQuarter-Height Blades Standard LOM Dual-Port MappingBlade Module Mezzanine Card C Port Mezzanine Card B Blade Module Mezz1FabC Port Mezz2FabB Blade ModuleMezz3FabC Port Mezz4FabB Blade Module Quad-Port Mezzanine Cards +8Port4 Module Port MappingHalf-Height BladesMezzFABCBlade n Example of I/O Module Port Assignments Half-Height Blade Integrated LOM1 Port n Integrated LOM2 Blade nBlade n Module Module Port Mapping-Quarter-Height BladesDual-Port Mezzanine Cards Sleeve Module Sleeve Module Quad-Port Mezzanine Cards Mellanox M4001F/M4001Q Infiniband Switch I/O Module Modules-SwitchesMellanox M4001F/M4001Q Infiniband Switch Module Dell PowerConnect KR 8024-k SwitchDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchDell PowerConnect M8428-k 10 Gb Converged Network Switch Mellanox M2401G DDR Infiniband Switch I/O ModuleMellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughInstalled Status/Identification IndicatorDell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module10/100/1000 Mb Ethernet Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module100/1000 Mb Ethernet Pass-Through I/O Module Brocade M4424 SAN I/O ModuleBrocade M4424 SAN I/O Module Brocade M5424 FC8 I/O Module Brocade M5424 FC8 I/O Module Module power indicator Page Removing a Blade Removing And Installing a BladeRecommended Tools Blade handle Removing The Sleeve Removing And Installing a SleeveInstalling a Blade Installing The Sleeve Power Supply ModulesRemoving a Power Supply Module Power Supply BlanksPower Cable Retention Clip Fan Modules Installing a Power Supply ModuleRemoving a Fan Module Installing a Fan ModuleRemoving a CMC Module Installing a CMC ModuleSelect the Reset CMC warm boot button Click the Power Management tabRemoving An iKVM Module Installing An iKVM ModuleIKVM Module Removing An I/O Module ModulesRemoving The Enclosure Bezel Installing An I/O ModuleEnclosure Bezel Enclosure Midplane Installing The Enclosure BezelRemoving The Front Module Cage Assembly And Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModulePage Troubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting I/O Modules Troubleshooting Fan ModulesTroubleshooting The iKVM Module Page Chassis Management Controller Module Enclosure SpecificationsPower Supply Module Optional Avocent iKVM ModuleBrocade FC4 Fibre Channel Switch Module Module SpecificationsPowerConnect M6220 Ethernet Switch Module Brocade FC8 Fibre Channel Switch ModuleFibre Channel Pass-Through Module Mellanox M4001F/M4001Q Infiniband Switch I/O ModuleMellanox Infiniband Switch Module Gb Ethernet Pass-Through ModuleDell PowerConnect M8024 10 Gb Ethernet switch I/O module Visit support.dell.com Contacting Dell