Dell BMX01 owner manual Power Supply Blanks, Removing a Power Supply Module

Page 75

NOTE: A 2700 W power supply module requires 110 V to 240 V input from an AC power source. If a power supply module is plugged into a 110 V electrical outlet, the power supply operates at 1350 W, if you select the Allow 110 VAC Operation check box in the CMC Power Configuration screen.

NOTE: The power supply modules have internal fans that provide thermal cooling to these modules. A power supply module must be replaced if an internal fan failure occurs.

The CMC module controls power management for the system. You can program the CMC to configure the power budget, redundancy, and dynamic power of the entire enclosure (chassis, servers, I/O modules, iKVM, CMC, and power supplies). The power management service optimizes power consumption and re-allocates power to different modules based on real-time demand. For more information, see the CMC User's Guide at support.dell.com/manuals.

NOTE: The wattage of a power supply module is listed on its regulatory label.

NOTE: PDU inlet cords for this system may be too thick to fit in the wire guides installed in the rack vertical rails. If this is the case, remove the wire guides by removing the attachment screw securing each guide. Route the PDU inlet cords along the vertical rails, securing them with tie wraps or strips.

Power Supply Blanks

If the M1000e enclosure is operated with only three power supplies, power supply blanks must be installed in the three unoccupied power supply bays (4 through 6) to maintain proper cooling airflow in the enclosure.

Removing A Power Supply Module

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE: The power supply modules are hot-swappable. Remove and replace only one power supply module at a time in a system that is turned on.

1.Release the retention clip on the power cable and disconnect the power cable from the power supply module.

2.Press down on the power supply module release button on the handle.

3.Rotate the power supply module handle down to eject the power supply module.

4.Slide the power supply module out of the enclosure.

75

Image 75
Contents Regulatory Model BMX01 Page Contents Configuring The I/O Modules Installing Enclosure Components Troubleshooting The Enclosure Technical SpecificationsGetting Help System Overview About Your SystemBlade Numbering Full Height Blades Blade Numbering Quarter Height Blades System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesConfiguration Wizard Using The LCD Module MenusCenter button Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsPower supply fault Icon Indicator Fan Module IndicatorsIndicator Description Power to the systemSolid Green Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features And Indicators CMC Module CMC Module FeaturesCMC Fail-Safe Mode Condition Description CMC removalCMC network cable Daisy-Chain CMC Network Connection Other Information You May Need System MessagesPage Initial Setup Sequence Initial CMC Network ConfigurationBefore You Begin Configuring The CMC Using a Management Station And CLI Configuring The CMC Using The LCD Configuration WizardLogging In To The CMC Using The Web-Based Interface Https//CMC IP addressHttps//CMC IP addressport number Configuring iDRAC Networking Using The Web-Based Interface Click Setup → DeployAdding And Managing CMC Users Setting The First Boot Device For Servers Configuring And Managing PowerInstalling Or Updating The CMC Firmware Updating The CMC Firmware Using The Web-Based Interface Updating The CMC Firmware Using RacadmDownloading The CMC Firmware Updating The iKVM Firmware Configuring The Optional iKVM Switch ModuleTiering The Avocent iKVM Switch From a Digital KVM Switch Tiering The Avocent iKVM Switch From An Analog KVM SwitchClick Setup → Devices → Device Modify Configuring The Analog SwitchViewing And Selecting Servers FlexAddress Plus FlexAddressFabric a General I/O Module Configuration GuidelinesNetwork Information ConnectivityFabric C Fabric BHalf-Height Blades PowerEdge M610x OnlyMezzanine Cards Full-Height BladesSupported I/O Module Configurations Dual-Port Mezzanine Cards Module Port Mapping-Full-Height BladesQuarter-Height Blades Standard LOM Dual-Port MappingBlade Module Mezzanine Card C Port Mezzanine Card B Blade Module Mezz1FabC Port Mezz2FabB Blade ModuleMezz3FabC Port Mezz4FabB Blade Module Quad-Port Mezzanine Cards Module Port MappingHalf-Height Blades MezzFABCBlade n+8Port4 Example of I/O Module Port Assignments Half-Height Blade Integrated LOM1 Port n Integrated LOM2 Blade nBlade n Module Module Port Mapping-Quarter-Height BladesDual-Port Mezzanine Cards Sleeve Module Sleeve Module Quad-Port Mezzanine Cards Mellanox M4001F/M4001Q Infiniband Switch I/O Module Modules-SwitchesMellanox M4001F/M4001Q Infiniband Switch Module Dell PowerConnect KR 8024-k SwitchDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchDell PowerConnect M8428-k 10 Gb Converged Network Switch Mellanox M2401G DDR Infiniband Switch I/O ModuleMellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughInstalled Status/Identification IndicatorDell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module10/100/1000 Mb Ethernet Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module100/1000 Mb Ethernet Pass-Through I/O Module Brocade M4424 SAN I/O ModuleBrocade M4424 SAN I/O Module Brocade M5424 FC8 I/O Module Brocade M5424 FC8 I/O Module Module power indicator Page Removing And Installing a Blade Recommended ToolsRemoving a Blade Blade handle Removing And Installing a Sleeve Installing a BladeRemoving The Sleeve Installing The Sleeve Power Supply ModulesRemoving a Power Supply Module Power Supply BlanksPower Cable Retention Clip Fan Modules Installing a Power Supply ModuleRemoving a Fan Module Installing a Fan ModuleRemoving a CMC Module Installing a CMC ModuleSelect the Reset CMC warm boot button Click the Power Management tabInstalling An iKVM Module IKVM ModuleRemoving An iKVM Module Removing An I/O Module ModulesInstalling An I/O Module Enclosure BezelRemoving The Enclosure Bezel Installing The Enclosure Bezel Removing The Front Module Cage Assembly And MidplaneEnclosure Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModulePage Troubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting Fan Modules Troubleshooting The iKVM ModuleTroubleshooting I/O Modules Page Chassis Management Controller Module Enclosure SpecificationsPower Supply Module Optional Avocent iKVM ModuleBrocade FC4 Fibre Channel Switch Module Module SpecificationsPowerConnect M6220 Ethernet Switch Module Brocade FC8 Fibre Channel Switch ModuleFibre Channel Pass-Through Module Mellanox M4001F/M4001Q Infiniband Switch I/O ModuleMellanox Infiniband Switch Module Gb Ethernet Pass-Through ModuleDell PowerConnect M8024 10 Gb Ethernet switch I/O module Visit support.dell.com Contacting Dell