I/O Modules—Switches
Configuring A Switch Module Network Ethernet Port Using The
You can use the CMC
NOTE: Use this procedure to configure the switch’s
NOTE: To change settings on the I/O module configuration page, you must have Fabric Administrator privileges for the particular Fabric in which the module is installed
NOTE: The network IP address set on the I/O module by the CMC is not saved to a configuration file. To save the IP address configuration permanently, use the connect
NOTE: Do not attempt to configure I/O module network settings for Ethernet
1.Log in to the CMC
2.Select I/O Modules in the Chassis menu in the system tree.
3.Select the Setup tab. The Configuring I/O Modules Network Settings page is displayed.
4.Configure the switch for integration into your network.
–Select DHCP Mode Enabled if your network uses a DHCP server to assign IP addresses.
–If your network uses static IP addressing, enter an IP address, subnet mask and gateway.
5.Click Apply.
6.Click the Deploy
After all I/O modules have been configured and connected, the enclosure’s blades can be inserted and booted with full network communication.
Mellanox M4001F/M4001Q Infiniband Switch I/O Module
The Mellanox M4001F/M4001Q Infiniband switch delivers 56 Gb/s at FDR speed and 40 Gb/s at QDR speed (full bisectional bandwidth per port). This switch module includes 16 Quad Small
51