Dell BMX01 owner manual Module Port Mapping-Full-Height Blades, Quarter-Height Blades

Page 37

Fabric A

Fabric B Mezzanine

Fabric C Mezzanine

I/O Bay A1, A2

I/O Bay B1, B2

I/O Bay C1, C2

 

Card

Card

 

 

 

 

 

 

 

 

 

 

 

 

or pass-

 

 

 

 

 

through

 

 

 

 

 

module

 

 

Standard

Infiniband mezzanine

Ethernet mezzanine

Ethernet

Infiniband

Ethernet switch

Integrated LOM

card

card

switch module

switch module

module or

 

 

 

or pass-

 

pass-through

 

 

 

through

 

module

 

 

 

module

 

 

Standard

Fibre channel

Ethernet mezzanine

Ethernet

Fibre channel

Ethernet switch

Integrated LOM

mezzanine card

card

switch module

switch or

module or

 

 

 

or pass-

pass-through

pass-through

 

 

 

through

module

module

 

 

 

module

 

 

Quarter-Height Blades

A quarter-height blade supports one mezzanine card. The mezzanine card slot supports Fabric B or Fabric C, depending on the slot in the sleeve where the blade is installed.

I/O Module Port Mapping—Full-Height Blades

NOTE: The I/O port mappings in the following sections are applicable only to the I/O Pass-Through Modules.

Standard LOM (Dual-Port) Mapping

Each LOM has two port connections. For a full-height blade in bay n:

Integrated LOM1, connection 1 connects to I/O module A1, port n.

Integrated LOM1, connection 2 connects to I/O module A2, port n.

Integrated LOM2, connection 1 connects to I/O module A1, port n+8.

Integrated LOM2, connection 2 connects to I/O module A2, port n+8.

For example, in a full-height blade in slot 5:

Integrated LOM1 connection 1 connects to I/O module A1, port 5.

Integrated LOM1 connection 2 connects to I/O module A2, port 5.

Integrated LOM2 connection 1 connects to I/O module A1, port 13.

Integrated LOM2 connection 2 connects to I/O module A2, port 13.

NOTE: Even though PowerEdge M610x is a full-height blade system, only one network controller (LOM1) is available.

For PowerEdge M610x blade in bay n, the integrated NIC connects to I/O module A1, port n and I/O module A2, port n.

Dual-Port Mezzanine Cards

Each mezzanine card has two port connections. For a full-height blade in bay n:

37

Image 37
Contents Regulatory Model BMX01 Page Contents Configuring The I/O Modules Installing Enclosure Components Technical Specifications Troubleshooting The EnclosureGetting Help System Overview About Your SystemBlade Numbering Full Height Blades Blade Numbering Quarter Height Blades System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesUsing The LCD Module Menus Configuration WizardCenter button Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsIndicator Description Fan Module IndicatorsPower to the system Power supply fault Icon IndicatorSolid Green Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features And Indicators CMC Module CMC Module FeaturesCondition Description CMC removal CMC Fail-Safe ModeCMC network cable Daisy-Chain CMC Network Connection Other Information You May Need System MessagesPage Initial CMC Network Configuration Initial Setup SequenceBefore You Begin Configuring The CMC Using a Management Station And CLI Configuring The CMC Using The LCD Configuration WizardHttps//CMC IP address Logging In To The CMC Using The Web-Based InterfaceHttps//CMC IP addressport number Click Setup → Deploy Configuring iDRAC Networking Using The Web-Based InterfaceAdding And Managing CMC Users Configuring And Managing Power Setting The First Boot Device For ServersInstalling Or Updating The CMC Firmware Updating The CMC Firmware Using Racadm Updating The CMC Firmware Using The Web-Based InterfaceDownloading The CMC Firmware Tiering The Avocent iKVM Switch From a Digital KVM Switch Configuring The Optional iKVM Switch ModuleTiering The Avocent iKVM Switch From An Analog KVM Switch Updating The iKVM FirmwareClick Setup → Devices → Device Modify Configuring The Analog SwitchViewing And Selecting Servers FlexAddress Plus FlexAddressNetwork Information General I/O Module Configuration GuidelinesConnectivity Fabric aFabric C Fabric BMezzanine Cards PowerEdge M610x OnlyFull-Height Blades Half-Height BladesSupported I/O Module Configurations Quarter-Height Blades Module Port Mapping-Full-Height BladesStandard LOM Dual-Port Mapping Dual-Port Mezzanine CardsBlade Module Mezzanine Card C Port Mezzanine Card B Blade Module Mezz1FabC Port Mezz2FabB Blade ModuleMezz3FabC Port Mezz4FabB Blade Module Quad-Port Mezzanine Cards MezzFABCBlade n Module Port MappingHalf-Height Blades+8Port4 Example of I/O Module Port Assignments Half-Height Blade Integrated LOM1 Port n Integrated LOM2 Blade nBlade n Module Module Port Mapping-Quarter-Height BladesDual-Port Mezzanine Cards Sleeve Module Sleeve Module Quad-Port Mezzanine Cards Mellanox M4001F/M4001Q Infiniband Switch I/O Module Modules-SwitchesMellanox M4001F/M4001Q Infiniband Switch Module Dell PowerConnect KR 8024-k SwitchDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchDell PowerConnect M8428-k 10 Gb Converged Network Switch Mellanox M2401G DDR Infiniband Switch I/O ModuleMellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughInstalled Status/Identification IndicatorDell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module10/100/1000 Mb Ethernet Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module100/1000 Mb Ethernet Pass-Through I/O Module Brocade M4424 SAN I/O ModuleBrocade M4424 SAN I/O Module Brocade M5424 FC8 I/O Module Brocade M5424 FC8 I/O Module Module power indicator Page Recommended Tools Removing And Installing a BladeRemoving a Blade Blade handle Installing a Blade Removing And Installing a SleeveRemoving The Sleeve Installing The Sleeve Power Supply ModulesRemoving a Power Supply Module Power Supply BlanksPower Cable Retention Clip Fan Modules Installing a Power Supply ModuleRemoving a Fan Module Installing a Fan ModuleRemoving a CMC Module Installing a CMC ModuleSelect the Reset CMC warm boot button Click the Power Management tabIKVM Module Installing An iKVM ModuleRemoving An iKVM Module Removing An I/O Module ModulesEnclosure Bezel Installing An I/O ModuleRemoving The Enclosure Bezel Removing The Front Module Cage Assembly And Midplane Installing The Enclosure BezelEnclosure Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModulePage Troubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting The iKVM Module Troubleshooting Fan ModulesTroubleshooting I/O Modules Page Power Supply Module Enclosure SpecificationsOptional Avocent iKVM Module Chassis Management Controller ModulePowerConnect M6220 Ethernet Switch Module Module SpecificationsBrocade FC8 Fibre Channel Switch Module Brocade FC4 Fibre Channel Switch ModuleMellanox Infiniband Switch Module Mellanox M4001F/M4001Q Infiniband Switch I/O ModuleGb Ethernet Pass-Through Module Fibre Channel Pass-Through ModuleDell PowerConnect M8024 10 Gb Ethernet switch I/O module Visit support.dell.com Contacting Dell