Dell BMX01 owner manual Viewing And Selecting Servers

Page 31

Resynchronizing The Server List At The Remote Client Workstation

Once the iKVM module is connected, the blades are displayed in OSCAR. You must re-synchronize the servers on any remote workstation to ensure that the blades are available to any remote users connected to the console switch through the Remote Console Switch software.

NOTE: This procedure only re-synchronizes one remote client workstation. With multiple client workstations, save the re-synchronized local database and load it into the other client workstations to ensure consistency.

To re-synchronize the server listing:

1.Click Resync in the Server category of the Management panel. The resync wizard launches.

2.Click Next. A warning message is displayed indicating that the database will be updated to match the current configuration of the console switch. Your current local database names will be overwritten with the switch names. To include unpowered SIPs in the re-synchronization, select the Include Offline SIPs check box.

3.Click Next. A Polling Remote Console Switch message box is displayed with a progress bar indicating that the switch information is being retrieved.

4.If no changes were detected in the appliance, a completion dialog box is displayed with this information. If server changes were detected, then the Detected Changes dialog box is displayed.

5.Click Next to update the database.

If a cascade switch was detected, the Enter Cascade Switch Information dialog box is displayed.

6.Select the type of switch connected to the appliance from the drop-down list. If the type you are looking for is not available, you can add it by clicking Add.

7.Click Next. The completion dialog box is displayed.

8.Click Finish to exit.

9.Start up the analog switch and the system.

Viewing And Selecting Servers

Use the OSCAR Main dialog box to view, configure, and manage servers in the M1000e enclosure through the iKVM. You can view the servers by name or by slot. The slot number is the chassis slot number the server occupies. The Slot column indicates the slot number in which a server is installed.

NOTE: Server names and slot numbers are assigned by the CMC.

NOTE: If you have enabled access to the CMC though the iKVM, an additional option, Dell CMC Console, is displayed.

To access the Main dialog box, press <Prnt Scrn> launch the iKVM Switch OSCAR. The Main dialog box is displayed.

or

If a password has been assigned, the Password dialog box is displayed. Type your password and click OK. The Main dialog box is displayed.

To toggle between quarter-height blades installed in a sleeve:

1.Press <Prnt Scrn> to launch the iKVM Switch OSCAR.

2.Select the slot where the sleeve and blade is installed and press <Enter> to exit OSCAR.

3.Press <Scroll Lock> twice to toggle between the quarter-height blades installed in the sleeve.

31

Image 31
Contents Regulatory Model BMX01 Page Contents Configuring The I/O Modules Installing Enclosure Components Technical Specifications Troubleshooting The EnclosureGetting Help System Overview About Your SystemBlade Numbering Full Height Blades Blade Numbering Quarter Height Blades System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesUsing The LCD Module Menus Configuration WizardCenter button Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsPower supply fault Icon Indicator Fan Module IndicatorsIndicator Description Power to the systemSolid Green Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features And Indicators CMC Module CMC Module FeaturesCondition Description CMC removal CMC Fail-Safe ModeCMC network cable Daisy-Chain CMC Network Connection Other Information You May Need System MessagesPage Initial CMC Network Configuration Initial Setup SequenceBefore You Begin Configuring The CMC Using a Management Station And CLI Configuring The CMC Using The LCD Configuration WizardHttps//CMC IP address Logging In To The CMC Using The Web-Based InterfaceHttps//CMC IP addressport number Click Setup → Deploy Configuring iDRAC Networking Using The Web-Based InterfaceAdding And Managing CMC Users Configuring And Managing Power Setting The First Boot Device For ServersInstalling Or Updating The CMC Firmware Updating The CMC Firmware Using Racadm Updating The CMC Firmware Using The Web-Based InterfaceDownloading The CMC Firmware Updating The iKVM Firmware Configuring The Optional iKVM Switch ModuleTiering The Avocent iKVM Switch From a Digital KVM Switch Tiering The Avocent iKVM Switch From An Analog KVM SwitchClick Setup → Devices → Device Modify Configuring The Analog SwitchViewing And Selecting Servers FlexAddress Plus FlexAddressFabric a General I/O Module Configuration GuidelinesNetwork Information ConnectivityFabric C Fabric BHalf-Height Blades PowerEdge M610x OnlyMezzanine Cards Full-Height BladesSupported I/O Module Configurations Dual-Port Mezzanine Cards Module Port Mapping-Full-Height BladesQuarter-Height Blades Standard LOM Dual-Port MappingBlade Module Mezzanine Card C Port Mezzanine Card B Blade Module Mezz1FabC Port Mezz2FabB Blade ModuleMezz3FabC Port Mezz4FabB Blade Module Quad-Port Mezzanine Cards MezzFABCBlade n Module Port MappingHalf-Height Blades+8Port4 Example of I/O Module Port Assignments Half-Height Blade Integrated LOM1 Port n Integrated LOM2 Blade nBlade n Module Module Port Mapping-Quarter-Height BladesDual-Port Mezzanine Cards Sleeve Module Sleeve Module Quad-Port Mezzanine Cards Mellanox M4001F/M4001Q Infiniband Switch I/O Module Modules-SwitchesMellanox M4001F/M4001Q Infiniband Switch Module Dell PowerConnect KR 8024-k SwitchDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchDell PowerConnect M8428-k 10 Gb Converged Network Switch Mellanox M2401G DDR Infiniband Switch I/O ModuleMellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughInstalled Status/Identification IndicatorDell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module10/100/1000 Mb Ethernet Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module100/1000 Mb Ethernet Pass-Through I/O Module Brocade M4424 SAN I/O ModuleBrocade M4424 SAN I/O Module Brocade M5424 FC8 I/O Module Brocade M5424 FC8 I/O Module Module power indicator Page Recommended Tools Removing And Installing a BladeRemoving a Blade Blade handle Installing a Blade Removing And Installing a SleeveRemoving The Sleeve Installing The Sleeve Power Supply ModulesRemoving a Power Supply Module Power Supply BlanksPower Cable Retention Clip Fan Modules Installing a Power Supply ModuleRemoving a Fan Module Installing a Fan ModuleRemoving a CMC Module Installing a CMC ModuleSelect the Reset CMC warm boot button Click the Power Management tabIKVM Module Installing An iKVM ModuleRemoving An iKVM Module Removing An I/O Module ModulesEnclosure Bezel Installing An I/O ModuleRemoving The Enclosure Bezel Removing The Front Module Cage Assembly And Midplane Installing The Enclosure BezelEnclosure Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModulePage Troubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting The iKVM Module Troubleshooting Fan ModulesTroubleshooting I/O Modules Page Chassis Management Controller Module Enclosure SpecificationsPower Supply Module Optional Avocent iKVM ModuleBrocade FC4 Fibre Channel Switch Module Module SpecificationsPowerConnect M6220 Ethernet Switch Module Brocade FC8 Fibre Channel Switch ModuleFibre Channel Pass-Through Module Mellanox M4001F/M4001Q Infiniband Switch I/O ModuleMellanox Infiniband Switch Module Gb Ethernet Pass-Through ModuleDell PowerConnect M8024 10 Gb Ethernet switch I/O module Visit support.dell.com Contacting Dell