NOTE: After installing a new power supply, allow several seconds for the system to recognize the power supply and determine whether it is working properly. The power supply DC power indicator turns green if the power supply is functioning properly.
3.If none of the power supplies show a fault LED and the blades do not power on, check the LCD display or CMC for status messages.
4.If the problem is not resolved, see Getting Help.
Troubleshooting Fan Modules
NOTE: The fan modules are hot swappable. Remove and replace only one fan module at a time in a system that is turned on. Operating the system without all six fan modules for extended periods of time can cause the system to overheat.
1.Locate the faulty fan. Each fan module has indicators that identify a faulty fan.
2.Remove the fan module.
3.Examine the blades for debris. If debris is present, carefully remove it.
4.Reseat the faulty fan.
5.If none of the fans show a fault LED and the blades do not power on, check the LCD display or CMC for status messages.
6.If the problem is not resolved, install a new fan.
7.If the new fan does not operate, see Getting Help.
Troubleshooting The iKVM Module
When using iDRAC video\console redirection, and you cannot see video through the iKVM when you switch to a blade running Linux, a typical cause is that a monitor or KVM appliance with a lower resolution has recently been added.
For example, a blade running X Windows under Linux is inserted and powered on. A user connects to the blade in OS GUI mode using the iDRAC and a video resolution is detected and
1.From the iDRAC session, exit and
2.Set all monitors or KVM appliances connected to the M1000e enclosure to the same resolution or higher as configured on the Linux blades in GUI mode.
3.From the lower resolution monitor (no video displayed) press <CTRL><ALT><F3> to change to the
4.Restart X Windows to detect and utilize the lower resolution.
Troubleshooting I/O Modules
NOTE: To eliminate the possibility of a hardware problem with the module or its attaching devices, first ensure that the module is properly initialized and configured.
1.Check that you have installed the module in an I/O slot that matches its fabric type.
2.Check that the