Dell BMX01 owner manual Module Port MappingHalf-Height Blades, MezzFABCBlade n, +8Port4

Page 43

Blade n and Blade (n + 8)

 

 

I/O Module

 

NOTE: n denotes a

 

 

 

 

B1

C1

C2

B2

variable value from 1

 

 

 

 

to 8.

 

 

 

 

 

 

 

 

 

Mezz_FAB_C_Blade n

 

 

Port(n+24)

 

+8_Port4

 

 

 

 

NOTE: Even though PowerEdge M610x is a full blade system, only two mezzanine card slots (MEZZ1_Fab_C1 and MEZZ2_FAB_B1) in the expansion bay are available for use. The other two slots on the system board (MEZZ1_FAB_C and MEZZ2_FAB_B) are occupied by the mezzanine interface card which provides connectivity between the PCIe expansion-card riser and the system board.

The following table illustrates the I/O module port mapping for PowerEdge M610x in bay n.

Table 6. Example of I/O Module Port Assignments - PowerEdge M610x Blade 1

Blade 1

 

 

I/O Module

 

 

 

 

 

 

 

 

A1

B1

C1

C2

B2

A2

Mezzanine Card C (port 1

 

Port 9

Port 9

 

 

and port 2)

 

 

 

 

 

Mezzanine Card C (port 3

 

Port 25

Port 25

 

 

and port 4)

 

 

 

 

 

Mezzanine Card B (port

Port 9

 

 

Port 9

 

1 and port 2)

 

 

 

 

 

Mezzanine Card B (port

Port 25

 

 

Port 25

 

1 and port 2)

 

 

 

 

 

I/O Module Port MappingHalf-Height Blades

Standard LOM (Dual-Port) and Network Daughter Card (Quad-Port) Mapping

Each standard LOM has two port connections. For a half-height blade in bay n:

Integrated LOM, connection 1 connects to I/O module A1, port n. Integrated LOM, connection 2 connects to I/O module A2, port n.

Half-height blades with network daughter card (M710HD) hosts two network controllers (LOM1 and LOM2), each with two port connections. For a half-height blade in bay n:

LOM1, connection 1 connects to I/O module A1, port n. LOM1, connection 2 connects to I/O module A2, port n.

LOM2, connection 1 connects to I/O module A1, port n+16. LOM2, connection 2 connects to I/O module A2, port n +16.

NOTE: If the I/O modules A1 and A2 are not quad-port capable, then the LOM2 ports (NIC3 and NIC4) gets disabled during system boot.

For example, in a half-height blade, in slot 5:

Integrated LOM1 connection 1 connects to I/O module A1, port 5.

Integrated LOM1 connection 2 connects to I/O module A2, port 5.

Integrated LOM2 connection 1 connects to I/O module A1, port 21.

43

Image 43
Contents Regulatory Model BMX01 Page Contents Configuring The I/O Modules Installing Enclosure Components Technical Specifications Troubleshooting The EnclosureGetting Help System Overview About Your SystemBlade Numbering Full Height Blades Blade Numbering Quarter Height Blades System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesUsing The LCD Module Menus Configuration WizardCenter button Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsPower supply fault Icon Indicator Fan Module IndicatorsIndicator Description Power to the systemSolid Green Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features And Indicators CMC Module CMC Module FeaturesCondition Description CMC removal CMC Fail-Safe ModeCMC network cable Daisy-Chain CMC Network Connection Other Information You May Need System MessagesPage Initial CMC Network Configuration Initial Setup SequenceBefore You Begin Configuring The CMC Using a Management Station And CLI Configuring The CMC Using The LCD Configuration WizardHttps//CMC IP address Logging In To The CMC Using The Web-Based InterfaceHttps//CMC IP addressport number Click Setup → Deploy Configuring iDRAC Networking Using The Web-Based InterfaceAdding And Managing CMC Users Configuring And Managing Power Setting The First Boot Device For ServersInstalling Or Updating The CMC Firmware Updating The CMC Firmware Using Racadm Updating The CMC Firmware Using The Web-Based InterfaceDownloading The CMC Firmware Updating The iKVM Firmware Configuring The Optional iKVM Switch ModuleTiering The Avocent iKVM Switch From a Digital KVM Switch Tiering The Avocent iKVM Switch From An Analog KVM SwitchClick Setup → Devices → Device Modify Configuring The Analog SwitchViewing And Selecting Servers FlexAddress Plus FlexAddressFabric a General I/O Module Configuration GuidelinesNetwork Information ConnectivityFabric C Fabric BHalf-Height Blades PowerEdge M610x OnlyMezzanine Cards Full-Height BladesSupported I/O Module Configurations Dual-Port Mezzanine Cards Module Port Mapping-Full-Height BladesQuarter-Height Blades Standard LOM Dual-Port MappingBlade Module Mezzanine Card C Port Mezzanine Card B Blade Module Mezz1FabC Port Mezz2FabB Blade ModuleMezz3FabC Port Mezz4FabB Blade Module Quad-Port Mezzanine Cards MezzFABCBlade n Module Port MappingHalf-Height Blades+8Port4 Example of I/O Module Port Assignments Half-Height Blade Integrated LOM1 Port n Integrated LOM2 Blade nBlade n Module Module Port Mapping-Quarter-Height BladesDual-Port Mezzanine Cards Sleeve Module Sleeve Module Quad-Port Mezzanine Cards Mellanox M4001F/M4001Q Infiniband Switch I/O Module Modules-SwitchesMellanox M4001F/M4001Q Infiniband Switch Module Dell PowerConnect KR 8024-k SwitchDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchDell PowerConnect M8428-k 10 Gb Converged Network Switch Mellanox M2401G DDR Infiniband Switch I/O ModuleMellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughInstalled Status/Identification IndicatorDell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module10/100/1000 Mb Ethernet Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module100/1000 Mb Ethernet Pass-Through I/O Module Brocade M4424 SAN I/O ModuleBrocade M4424 SAN I/O Module Brocade M5424 FC8 I/O Module Brocade M5424 FC8 I/O Module Module power indicator Page Recommended Tools Removing And Installing a BladeRemoving a Blade Blade handle Installing a Blade Removing And Installing a SleeveRemoving The Sleeve Installing The Sleeve Power Supply ModulesRemoving a Power Supply Module Power Supply BlanksPower Cable Retention Clip Fan Modules Installing a Power Supply ModuleRemoving a Fan Module Installing a Fan ModuleRemoving a CMC Module Installing a CMC ModuleSelect the Reset CMC warm boot button Click the Power Management tabIKVM Module Installing An iKVM ModuleRemoving An iKVM Module Removing An I/O Module ModulesEnclosure Bezel Installing An I/O ModuleRemoving The Enclosure Bezel Removing The Front Module Cage Assembly And Midplane Installing The Enclosure BezelEnclosure Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModulePage Troubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting The iKVM Module Troubleshooting Fan ModulesTroubleshooting I/O Modules Page Chassis Management Controller Module Enclosure SpecificationsPower Supply Module Optional Avocent iKVM ModuleBrocade FC4 Fibre Channel Switch Module Module SpecificationsPowerConnect M6220 Ethernet Switch Module Brocade FC8 Fibre Channel Switch ModuleFibre Channel Pass-Through Module Mellanox M4001F/M4001Q Infiniband Switch I/O ModuleMellanox Infiniband Switch Module Gb Ethernet Pass-Through ModuleDell PowerConnect M8024 10 Gb Ethernet switch I/O module Visit support.dell.com Contacting Dell