Dell BMX01 owner manual Configuring The Optional iKVM Switch Module, Updating The iKVM Firmware

Page 29

For complete instructions on how to configure and operate the CMC module, see the latest CMC User's Guide at

support.dell.com/manuals.

Configuring The Optional iKVM Switch Module

Updating The iKVM Firmware

NOTE: The iKVM resets and becomes temporarily unavailable after the firmware has been uploaded successfully.

1.Log in to the CMC web-based interface.

2.Select Chassis in the system tree.

3.Click the Update tab. The Updatable Components page is displayed.

4.Click the iKVM name. The Firmware Update page is displayed.

5.In the Value field, type the path on your management station or shared network where the firmware image file resides, or click Browse to navigate to the file location.

NOTE: The default iKVM firmware image name is ikvm.bin. However, the iKVM firmware image name can be renamed. If you are unable to locate ikvm.bin, verify if another user has renamed the file.

6.Click Update. A dialog box prompts you to confirm the action.

7.Click Yes to continue.

When the update is complete, the iKVM resets.

Tiering The Avocent iKVM Switch From A Digital KVM Switch

The iKVM module may also be tiered from a digital KVM switch such as the Dell 2161DS-2 or 4161DS, or a supported Avocent digital KVM switch. Many switches may be tiered without the need for a Server Interface Pod (SIP).

The cabling requirements for various external digital KVM switches are as follows:

Dell PowerConnect 2161DS, 4161DS, 2161DS-2, 2321DS (version 1.3.40.0 or later) or Avocent DSR x02x (except 1024), x03x (version 3.6 or later): Seamless tiering using ACI port and Cat 5 cable

Avocent DSR 800, x16x, x010, 1024: Avocent USB SIP (DSRIQ-USB) with Cat 5 cable

To tier the iKVM module from a Dell 2161DS, 180AS, or 2160AS console switch:

If the switch does not require a SIP to connect to the iKVM , connect a Cat 5 (or newer) cable to the RJ-45 ACI port on the iKVM module. Connect the other end of this cable to the ARI port on the external switch.

If the switch requires a USB SIP, connect an Avocent USB SIP to the iKVM, then connect a Cat 5 (or newer) cable to the SIP. Connect the other end of this cable to the ARI port on the external switch.

Once the KVM switch is connected, the server modules are displayed in OSCAR.

NOTE: You must also re-synchronize the server list from the Remote Console Switch software to view the list of blades.

Tiering The Avocent iKVM Switch From An Analog KVM Switch

The Avocent iKVM switch can be tiered from analog KVM switches such as the Dell 2160AS and 180AS, as well as many Avocent analog KVM switches. Many switches may be tiered without the need for a SIP.

The cabling requirements for specific external switches are as follows:

29

Image 29
Contents Regulatory Model BMX01 Page Contents Configuring The I/O Modules Installing Enclosure Components Getting Help Troubleshooting The EnclosureTechnical Specifications System Overview About Your SystemBlade Numbering Full Height Blades Blade Numbering Quarter Height Blades System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesCenter button Configuration WizardUsing The LCD Module Menus Back-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsIndicator Description Fan Module IndicatorsPower to the system Power supply fault Icon IndicatorSolid Green Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features And Indicators CMC Module CMC Module FeaturesCMC network cable CMC Fail-Safe ModeCondition Description CMC removal Daisy-Chain CMC Network Connection Other Information You May Need System MessagesPage Before You Begin Initial Setup SequenceInitial CMC Network Configuration Configuring The CMC Using a Management Station And CLI Configuring The CMC Using The LCD Configuration WizardHttps//CMC IP addressport number Logging In To The CMC Using The Web-Based InterfaceHttps//CMC IP address Adding And Managing CMC Users Configuring iDRAC Networking Using The Web-Based InterfaceClick Setup → Deploy Installing Or Updating The CMC Firmware Setting The First Boot Device For ServersConfiguring And Managing Power Downloading The CMC Firmware Updating The CMC Firmware Using The Web-Based InterfaceUpdating The CMC Firmware Using Racadm Tiering The Avocent iKVM Switch From a Digital KVM Switch Configuring The Optional iKVM Switch ModuleTiering The Avocent iKVM Switch From An Analog KVM Switch Updating The iKVM FirmwareClick Setup → Devices → Device Modify Configuring The Analog SwitchViewing And Selecting Servers FlexAddress Plus FlexAddressNetwork Information General I/O Module Configuration GuidelinesConnectivity Fabric aFabric C Fabric BMezzanine Cards PowerEdge M610x OnlyFull-Height Blades Half-Height BladesSupported I/O Module Configurations Quarter-Height Blades Module Port Mapping-Full-Height BladesStandard LOM Dual-Port Mapping Dual-Port Mezzanine CardsBlade Module Mezzanine Card C Port Mezzanine Card B Blade Module Mezz1FabC Port Mezz2FabB Blade ModuleMezz3FabC Port Mezz4FabB Blade Module Quad-Port Mezzanine Cards +8Port4 Module Port MappingHalf-Height BladesMezzFABCBlade n Example of I/O Module Port Assignments Half-Height Blade Integrated LOM1 Port n Integrated LOM2 Blade nBlade n Module Module Port Mapping-Quarter-Height BladesDual-Port Mezzanine Cards Sleeve Module Sleeve Module Quad-Port Mezzanine Cards Mellanox M4001F/M4001Q Infiniband Switch I/O Module Modules-SwitchesMellanox M4001F/M4001Q Infiniband Switch Module Dell PowerConnect KR 8024-k SwitchDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchDell PowerConnect M8428-k 10 Gb Converged Network Switch Mellanox M2401G DDR Infiniband Switch I/O ModuleMellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughInstalled Status/Identification IndicatorDell 10 GbE KR Pass-Through I/O Module Dell 10 GbE KR Pass-Through I/O Module10/100/1000 Mb Ethernet Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module100/1000 Mb Ethernet Pass-Through I/O Module Brocade M4424 SAN I/O ModuleBrocade M4424 SAN I/O Module Brocade M5424 FC8 I/O Module Brocade M5424 FC8 I/O Module Module power indicator Page Removing a Blade Removing And Installing a BladeRecommended Tools Blade handle Removing The Sleeve Removing And Installing a SleeveInstalling a Blade Installing The Sleeve Power Supply ModulesRemoving a Power Supply Module Power Supply BlanksPower Cable Retention Clip Fan Modules Installing a Power Supply ModuleRemoving a Fan Module Installing a Fan ModuleRemoving a CMC Module Installing a CMC ModuleSelect the Reset CMC warm boot button Click the Power Management tabRemoving An iKVM Module Installing An iKVM ModuleIKVM Module Removing An I/O Module ModulesRemoving The Enclosure Bezel Installing An I/O ModuleEnclosure Bezel Enclosure Midplane Installing The Enclosure BezelRemoving The Front Module Cage Assembly And Midplane Front module cage assembly Enclosure Torx T20 screws Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModulePage Troubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting I/O Modules Troubleshooting Fan ModulesTroubleshooting The iKVM Module Page Power Supply Module Enclosure SpecificationsOptional Avocent iKVM Module Chassis Management Controller ModulePowerConnect M6220 Ethernet Switch Module Module SpecificationsBrocade FC8 Fibre Channel Switch Module Brocade FC4 Fibre Channel Switch ModuleMellanox Infiniband Switch Module Mellanox M4001F/M4001Q Infiniband Switch I/O ModuleGb Ethernet Pass-Through Module Fibre Channel Pass-Through ModuleDell PowerConnect M8024 10 Gb Ethernet switch I/O module Visit support.dell.com Contacting Dell