For complete instructions on how to configure and operate the CMC module, see the latest CMC User's Guide at
support.dell.com/manuals.
Configuring The Optional iKVM Switch Module
Updating The iKVM Firmware
NOTE: The iKVM resets and becomes temporarily unavailable after the firmware has been uploaded successfully.
1.Log in to the CMC
2.Select Chassis in the system tree.
3.Click the Update tab. The Updatable Components page is displayed.
4.Click the iKVM name. The Firmware Update page is displayed.
5.In the Value field, type the path on your management station or shared network where the firmware image file resides, or click Browse to navigate to the file location.
NOTE: The default iKVM firmware image name is ikvm.bin. However, the iKVM firmware image name can be renamed. If you are unable to locate ikvm.bin, verify if another user has renamed the file.
6.Click Update. A dialog box prompts you to confirm the action.
7.Click Yes to continue.
When the update is complete, the iKVM resets.
Tiering The Avocent iKVM Switch From A Digital KVM Switch
The iKVM module may also be tiered from a digital KVM switch such as the Dell
The cabling requirements for various external digital KVM switches are as follows:
•Dell PowerConnect 2161DS, 4161DS,
•Avocent DSR 800, x16x, x010, 1024: Avocent USB SIP
To tier the iKVM module from a Dell 2161DS, 180AS, or 2160AS console switch:
•If the switch does not require a SIP to connect to the iKVM , connect a Cat 5 (or newer) cable to the
•If the switch requires a USB SIP, connect an Avocent USB SIP to the iKVM, then connect a Cat 5 (or newer) cable to the SIP. Connect the other end of this cable to the ARI port on the external switch.
Once the KVM switch is connected, the server modules are displayed in OSCAR.
NOTE: You must also
Tiering The Avocent iKVM Switch From An Analog KVM Switch
The Avocent iKVM switch can be tiered from analog KVM switches such as the Dell 2160AS and 180AS, as well as many Avocent analog KVM switches. Many switches may be tiered without the need for a SIP.
The cabling requirements for specific external switches are as follows:
29