Dell S100, S300 manual Installing the Drivers

Page 45

cWait until the Windows Setup screen appears with S = Specify Additional Device. Press <S> on the keyboard.

dInsert the requested media disk (as applicable) and press <Enter>.

8At the Select the driver to be installed window, select Dell PERC S100, S300 Controller... Click Next to load the driver files.

For Microsoft Windows Server 2003: When you are asked to load additional drivers, press <Enter> to start the Microsoft Windows installation process.

9Perform the remaining operating system installation instructions. Some of the windows require user-specific password and system information. As required, contact your IT administrator for assistance

For Microsoft Windows Server 2003 only: Two warning dialog boxes appear during the Installing Windows segment of the installation:

At the Software Installation dialog box, click Yes.

At the Hardware Installation dialog box, click Yes.

NOTE: When the operating system installation process is finished, remove the installation media inserted in step 7.

Performing the PERC S100 Controller or PERC S300 Controller Management Setup Procedure

The PERC S100 adapter or PERC S300 adapter management setup procedure is described in Dell OpenManage Server Administrator Storage Management. To set up a PERC S100 adapter or PERC S300 adapter on your system, see the Storage Management procedures located at the Dell Support website at support.dell.com/manuals.

Installing the Drivers

45

Image 45
Contents User’s Guide February Contents Complete the Hardware Installation Installing the Perc S300 AdapterInstalling the Microsoft Windows Drivers Physical Disk-Related ErrorsIndustry Canada Notice Canada Only RAID Technology Understanding Disk ArraysContents Page Safety When Working Inside Your System Safety GeneralProtecting Against Electrostatic Discharge Page Introduction OverviewOverview Supported Platforms Physical disks RequirementsOverview Boot to it Summary of RAID Levels About RAIDRAID Terminology Disk StripingDisk Mirroring Parity Data Spanned RAID LevelsExample of Distributed Parity RAID Features General FeaturesDescription Description Allows hot-swapping Physical disks, in the same virtual disk That supports hot-swapping DisksBackplane with hot-swap capability Features Migration during an OCE Virtual diskSpecifications RAID Hardware Installation Before You BeginGeneral Considerations Installing the Perc S300 Adapter Installing a Perc S300 Adapter Connecting the Cables Connect Physical Disks to the Perc S300 Adapter Complete the Hardware InstallationHardware Installation Installing the Drivers Installing the Microsoft Windows DriversDownloading the Controller Driver Media Pre-Installation Requirements for the Controller Drivers Operating System And Device Driver MediaTo Use Sata Controller to either ATA Mode or Ahci Pre-Installation Procedures For The Controller Drivers Steps DVD, and so on, perform the following For Microsoft Windows Server 2008 and Windows Server 2008 R2 For Microsoft Windows Server For Microsoft Windows Server 2008 and Windows Server 2008 R2 Installing the Drivers Installing the Drivers Perc Virtual Disk Management Utility Operations Description RAID Configuration ManagementAccessing the Perc Virtual Disk Management Utility Perc Virtual Disk Management Text Colors Description Initializing Physical Disks Before You Begin Creating Virtual DisksRAID Configuration and Management Deleting Virtual Disks RAID Configuration and Management Swapping Two Virtual Disks Managing Global Hot Spares Create a Global Hot SpareDelete a Global Hot Spare Viewing Virtual Disk Details Viewing Physical Disk DetailsController Options Description How to Operate Rescanning DisksController Options Pause if Degraded Continuing to BootRAID Configuration and Management Troubleshooting System Startup ProblemsRAID Mode to ATA Mode Boot Mode, Boot Sequence Bios Bios Screen Corrective Action Lost This warning message appears when multiple virtual disks are This warning message appears when From virtual disk creation Virtual Disk-Related Errors A Virtual Disk is in a Failed State On the virtual diskRedundant virtual disk 12. Cannot Create a Global Hot Spare Select View Virtual Disk Details 14. a Dedicated Hot Spare Fails Physical Disk-Related ErrorsTroubleshooting Appendix a Controller SpecificationsRead, Write, and Cache Policy S300 adapterPhysical Disk Tasks Controller TasksTable A-3. Physical Disk Tasks Physical Disk Task Name Perc S300 adapterSupported RAID Levels Virtual Disk TasksTable A-4. Virtual Disk Tasks Virtual Disk Task Name AdapterVirtual Disk Specifications RAID Technology Understanding Disk Arrays and Virtual Disks Appendix BUnderstanding RAID Levels Appendix B Table B-2. Physical Disk States Definition Disk States Virtual and Physical DisksTable B-3. Virtual Disk States State Definition Failure StatesCreating Virtual Disks Future Expansion Table B-5. Minimum and Maximum Physical Disk ConfigurationsUnderstanding Physical Disks Physical Disk StatesRescanning Physical Disks for Changes in State Dedicated Hot SparesGlobal Hot Spares Regulatory Notices Appendix CFCC, Class a FCC Notice U.S. OnlyFCC, Class B CE Notice European Union Industry Canada Notice Canada OnlyIndustry Canada, Class a Industry Canada, Class BAppendix C CE Mark Notice Contacting Dell Appendix DAppendix D Index Index Index 100 101 102 103 Glossary104 105 106 Acronym for nanoseconds, one billionth of a second 107108 109 110