Table
Warning Message | Corrective Action |
|
|
WARNING: Found | This warning message appears when multiple virtual disks are |
virtual disks | in Degraded and Failed state and Pause if Degraded or |
that are | Pause if Failed are set to ON at the PERC Virtual Disk |
Degraded and | Management utility. |
Failed | The following message appears after the warning is displayed: |
| |
| to enter setup |
| Press <Enter> to allow the operating system to continue its |
| boot, or press <Ctrl><R> to enter into the PERC Virtual Disk |
| Management utility to investigate the cause of the Degraded |
| and Failed virtual disks. |
| NOTE: A boot virtual disk that is in a Failed state prevents the |
| operating system from booting. |
| To investigate the cause, check for the following: |
| • Whether the virtual disk is in Degraded status because one of |
| the physical disks of a RAID 1 or RAID 5 virtual disk has |
| failed, or one of the physical disks of a RAID 10 virtual disk |
| has failed. |
| Press <Ctrl><R> and verify if the physical disks are offline |
| or missing. Remove and replace a failed physical disk. A |
| second physical disk failure could cause a Degraded virtual |
| disk to change to Failed status. |
| • Whether the virtual disk is in a Failed status because one or |
| more of the physical disks have failed. |
| Press <Ctrl><R> and verify if the physical disks are offline |
| or missing. Remove and replace the failed physical disk or |
| disks. |
Troubleshooting